M2T-2X250-12-_
904-M2T-2X250-12-04
Installation Instructions for Monorail 2 Circuit 2 X 250
Mount Magnetic Transformer
120 Volt Input to 12 Volt Single
Watt Surface
Feed Output
SAVE THESE INSTRUCTIONS!
GENERAL INFORMATION IMPORTANT SAFETY INSTRUCTIONS
- RISK OF FIRE: This product must be installed by a
qualified electrician. Turn the power to the electrical box off
during installation. Read the "Important Safety Instructions"
before installation.
- This product is suitable only for indoor dry locations and
approved for the use at any height above the finished floor.
- This product contains a magnetic transformer with a built-in
dimming coil.
- Do not install this lighting system in a damp or wet
location.
- Do not conceal or extend bus bar conductor through
building wall.
- To reduce the risk of fire and burns, do not install this
lighting system where the insulated open bus bar
conductors can be shorted or contact any conductive
materials.
- This product may be dimmed only with a low voltage
magnetic dimmer. Using a dimmer other than specified may
work initially, but will eventually cause transformer failure
and void the warranty. The dimmer must be derated as
indicated by the dimmer manufacturer.
- A typical installation is shown. Specific installation must be
in accordance with the local electrical codes.
- Load each circuit of the surface mount transformer to
MAXIMUM 250 Watt.
- To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
- Do not install fixture assemblies closer than six inches, or
as specified in the fixture installation instructions, to
curtains or similarly combustible materials.
- Turn the electrical power off before modifying the lighting
system in any way.
- The fixtures used with the Edge Lighting systems must be
identified for use with the corresponding Edge Lighting
systems.
- Minimum volume of the electrical box must be 6 cubic
inches (98 cubic centimeters).
- The system is "ETL" listed for USA and Canada only when
all the products used are supplied by Edge Lighting.
1
![](/html/b3/b3bd/b3bde214546a3eb3b8cbc6ea759ebec4f06e0b2c09a00de143012d22fc50aa1f/bg2.png)
Install the Surface Mount Transformer
A
M4 BUTTON HEAD SCREW
1
1
2: Unhook the transformer cover from the set screw and
remove it from the transformer housing.
C
3
2MM ALLEN WRENCH
1
COVER
CROSSBAR
ASSEMBLY
1: Loosen and remove the five M4 button head screws around
the transformer cover with the provided 2mm Allen wrench.
B
SET SCREW
2
COVER
3: Remove the inside nut and washer to remove the crossbar
assembly. DO NOT DISASSEMBLE THE CROSSBAR
ASSEMBLY.
HOUSING
WASHER
NOTE:
The 120 volt transformer wires must be connected to the
same phase of 120 volt power wires.
4: Connect one set of provided white and black extension wires
to the neutral and hot power wires coming from a switch
respectively with the wire nuts provided.
5: Connect the other set of provided white and black extension
wires to the neutral and hot power wires coming from the
other switch respectively with the wire nuts provided.
6: Feed the extension wires through the crossbar assembly
nipple.
7: Place all wires and wire nut connections inside the electrical
box.
8: Mount the crossbar assembly to the electrical box with the
two provided #8-32 screws.
9: Make sure the crossbar assembly is grounded in accordance
with local electrical codes.
INSIDE NUT
D
4
#8-32 SCREW
EXTENSION WIRES
9
7
5
8
6
CROSSBAR ASSEMBLY
NIPPLE
2
2