Edge Lighting 17 Port Linear Canopies Without Transformers User Manual

© 2012 Edge Lighting. All Rights Reserved.
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
FJC-33RE-_
Installation Instructions for 14 or 17 Port Rectangle Fast Jack
Canopy Only
IMPORTANT INFORMATION
- This product is ETL listed for indoor dry locations.
SAVE THESE INSTRUCTIONS!
Running the Power from a Remote Transformer to the Fast Jack Canopy
904-FJC-33RE-01
A
ELECTRICAL BOX
MAX
1
1: Remove the fourteen #8-32 screws around the canopy to
remove the mounting plate.
20FT
FAST JACK CANOPY
REMOTE TRANSFORMER
CONDUIT
1: Run the low voltage wires from a remote transformer to electrical box where Fast Jack canopy is going to be installed. It is recommended to install the remote transformer near the electrical box to avoid voltage drop. Refer to the instructions provided with remote transformer for low voltage wire size chart. Refer to the low voltage wire size chart provided with the remote transformer.
Install the Canopy
B
#8-32 SCREW
1
CANOPY
MOUNTING PLATE
1
C
NOTE: It is recommended that a person to hold the mounting
plate while the electrician installs it.
2
3
#8-32 SCREW
3
MOUNTING PLATE
Feed the power wires through mounting plate center hole.
2:
3:
Align the mounting plate slots with the electrical box holes and secure it to the electrical box holes with the provided two #8-32 screws.
1
D
ANCHOR
4
5
4: Tap the anchors through the mounting plate holes onto the
marked point up to the threaded portion with a hammer.
5: Screw in the threaded portion of the anchors with a Phillips screwdriver.
NOTE: All 4 anchors must be installed to balance the pendants
weight.
MOUNTING PLATE
6: Secure the mounting plate to the anchors with the provided #8 screws and washers.
F
8
FAST JACK CANOPY
ELECTRICAL BOX
8
E
WASHER
6
6
#8 SCREW
7: Make sure that the mounting plate is grounded in accordance with local electrical codes.
NOTE: Make sure a person holds the Fast Jack canopy while the
electrician connects the wires and completes the installation.
8: Connect each canopy wire to one low voltage transformer wire with a wire nut.
G
#8-32 SCREW
9
MOUNTING PLATE
MOUNTING PLATE
9: Place all wires and wire nut connections inside the canopy.
10: Place the canopy onto the mounting plate and tighten the
fourteen #8-32 screws.
H
11
FAST JACK FIXTURE CONNECTOR
FAST JACK CANOPY PORT
10
FAST JACK CANOPY
CAUTION: Risk of Fire: The total load of the Fast Jack
canopy ports should not exceed the remote transformer rated capacity.
11:
Use fingers to tighten each Fast Jack fixture connector into
one Fast Jack canopy port.
10
2
Loading...