Edge-Core ECS4100-26TX, ECS4100-26TX-ME, ECS4100-28T, ECS4100-52T Quick Start Manual

Page 1
Quick Start Guide
2
1
1
2
1
2
1
2
1
1
2
26-Port L2+ 10G Ethernet Switch (ECS4100-26TX/ECS4100-26TX-ME) 28-Port L2+ Gigabit Ethernet Switch (ECS4100-28T) 52-Port L2+ Gigabit Ethernet Switch (ECS4100-52T)
1. Unpack the Switch and Check Contents
ECS4100-26TX
ECS4100-26TX-ME
Caution:
people. One person should position the switch in the rack, while the other secures it using the rack screws.
Note:
using the included adhesive rubber foot pads.
Installing the switch in a rack requires two
The switch can also be installed on a desktop or shelf
ECS4100-28T
ECS4100-52T
Rack Mounting Kit—two brackets and eight screws
Power Cord—either Japan, US, Continental Europe or UK
Console Cable—RJ-45 to DB-9
Documentation—Quick Start Guide (this document) and Safety and Regulatory Information
Note:
The ECS4100 series switches are for indoor use only.
Note:
For Safety and Regulatory information, refer to the Safety and Regulatory Information document included with the switch.
Note:
Other documentation, including the Installation Guide, Web Management Guide, and CLI Reference Guide, can be obtained from www.edge-core.com.
3. Ground the Switch
Ensure the rack on which the switch is to be mounted is properly grounded and in compliance with ETSI ETS 300 253. Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment).
Attach a lug (not provided) to a #12 AWG (PoE switch) or #18 AWG (non-PoE switch) minimum grounding wire (not provided), and connect it to the grounding point on the switch using 3.5 mm screw with washer. Then connect the other end of the wire to rack ground.
Caution
unless all supply connections have been disconnected.
Caution:
location. It should have a separate protective earthing terminal on the chassis that must be permanently connected to earth to adequately ground the chassis and protect the operator from electrical hazards.
:
The earth connection must not be removed
The device must be installed in a restricted-access
2. Mount the Switch
Attach the brackets to the switch.
Use the screws and cage nuts supplied with the rack to secure the switch in the rack.
www.edge-core.com
4. Connect Power
a. Connect AC Power
Plug the AC power cord into the socket on the rear of the switch.
Connect the other end of the power cord to an AC power source. Verify that the external AC power requirements for the switch can be met as listed below:
ECS4100-26TX: AC 100-240 V, 50/60 Hz, 1 A ECS4100-28T: AC 100-240 V, 50/60 Hz, 1 A ECS4100-52T: AC 100-240 V, 50/60 Hz,1 A
Note:
line cord. You must use a line cord set that has been approved for the socket type in your country.
– 1 –
For International use, you may need to change the AC
E012017-AP-R02
150200001586A
Page 2
Quick Start Guide
2
1
3
123
1
3
1
2
1
2
3
2
1
123
b. Connect DC power to ECS4100-26TX-ME
Note:
Before wiring the DC plug or connecting power to the
switch, ensure that power to the feed lines is turned off at the supply circuit breaker or disconnected from the power bus.
The ECS4100-26TX-ME switch supports the option of connecting an external 36 to 60 VDC power source to its DC terminal block.
Connect the 36 VDC power feed wire to the DC plug “+” pin.
Connect the ground/return wire to the DC plug “-” pin.
5. Verify Switch Operation
7. Connect Network Cables
For RJ-45 ports, connect 100-ohm Category 5, 5e or better twisted-pair cable.
For the SFP/SFP+ slots, first install SFP/SFP+ transceivers and then connect fiber optic cabling to the transceiver ports. The following transceivers are supported:
1000BASE-SX (ET4201-SX)
1000BASE-LX (ET4201-LX)
1000BASE-ZX (ET4201-ZX)
1000BASE-LHX (ET4201-LHX)
10GBASE-SR (ET5402-SR)
10GBASE-LR (ET5402-LR)
10GBASE-ER (ET5402-ER)
As connections are made, check the port status LEDs to be sure the links are valid. Press the Mode button to change from Ethernet to PoE status:
On/Blinking Green — Port has a valid link. Blinking indicates network activity.
On Amber — Port is supplying PoE power.
Verify basic switch operation by checking the system LEDs. When operating normally, the Power and Diag LEDs should
be on green.
6. Perform Initial Configuration
Connect a PC to the switch console port using the included console cable.
Configure the PC’s serial port: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.
Log in to the CLI using default settings: Username “admin” and password “admin.”
Note:
For further information on switch configuration, refer
to the Web Management Guide and CLI Reference Guide.
– 2 –
Page 3
Hardware Specifications
Switch Chassis
Quick Start Guide
Size (W x D x H) ECS4100-26TX/ECS4100-26TX-ME/
ECS4100-28T/ECS4100-52T: 44 x 22 x 4.4 cm (17.32 x 8.66 x 1.73 in. )
Weight ECS4100-26TX: 2.2 kg (4.85 lb)
ECS4100-26TX-ME: 2.36 kg (5.20 lb) ECS4100-28T: 2.2 kg (4.85 lb) ECS4100-52T: 2.5 kg (5.5 lb)
Temperature Operating: 0 ° C to 50 ° C (32 ° F to 122 ° F)
Operating: 0 ° C to 45 ° C (32 ° F to 113 ° F, ECS4100-52T only) Storage: -40 ° C to 70 ° C (-40 ° F to 158 ° F)
Humidity Operating: 10% to 90% (non-condensing)
Power Specification
AC Input Power ECS4100-26TX: AC 100-240 V, 50/60 Hz, 1 A
ECS4100-28T: AC 100-240 V, 50/60 Hz, 1 A ECS4100-52T: AC 100-240 V, 50/60 Hz, 1 A
AC-DC Power Adapter
Input: AC 100-240 V, 50/60 Hz, 1 A
Output: 36-60 VDC, 2 A (ECS4100-26TX­ME)
Tota l Power Consumption
ECS4100-26TX: 20 W
ECS4100-26TX-ME: 20 W
ECS4100-28T: 20 W
ECS4100-52T: 40 W
Regulatory Compliances
Emissions CE Mark
EN 55022, Class A
FCC Class A
BSMI Certificate
Immunity IEC 61000-3-3, 61000-4-2/3/4/5/6/11
Safety UL/CUL(UL60950-1, CSA60950-1)
UL 60950-1, 2nd Edition, 2014-10-14
CAN/CSA C22.2 No. 60950-1-07, 2nd Edition,
2014-10
IEC 60950-1:2005 (2nd Edition); Am 1:2009+
Am 2:2013
EN 60950-1:2006+A11:2009+A1:2010+A12:2011
+A2:2013
CB (IEC/EN 60950-1)
BSMI CNS14336-1
– 3 –