Edge-Core AS7816-64X Quick Start Manual

Page 1
– 1 –
Quick Start Guide
Attach the Brackets
1. Attach each of the front- and rear-post brackets to the switch
using four of the included bracket screws.
2. Use an additional two screws to secure each of the rear-post
brackets at the mid-point on the sides of the switch.
the switch in the rack.
Adjust Rear-Post Bracket Ears
1. Lock the position of the rear-post bracket ears using the included
position-locking screws.
You can also adjust the rear-post bracket ears to fit different rack depths from 56 cm to 75 cm.
Connect Power
1. Install one or two AC PSUs in the switch.
The switch supports up to two PSUs that must have the same matching airflow direction as the installed fan tray.
2. Connect an external AC power source to the PSUs.
Caution:
The switch includes plug-in power supply (PSU) and fan tray modules that are installed into its chassis. All installed modules must have a matching airflow direction. That is, if the installed power modules have a front-to-back (F2B) airflow direction, all the installed fan tray modules must also have a F2B airflow direction.
Note:
The switch has the Open Network Install Environment (ONIE) software installer preloaded on the switch, but no switch software image. Information about compatible switch software can be found at
www.edge-core.com.
Note:
The switch drawings in this document are for illustration only and may not match your particular switch model.
Caution:
Installing the switch in a rack requires two
people. One person should position the switch in the rack, while the other person secures it using the rack screws.
装置の吸排気に必要な領域 を マニ ュ ア ル上に規定 し て いる。
1
1
1
2
3
2
1
3
1
2
E022018-CS-R01
150200001781A
www.edge-core.com
64-Port 100G Top-of-Rack Switch
AS7816-64X
1.
100G Top-of-Rack Switch
AS7816-64X
2. Rack Mounting Kit—2 front-post brackets, 2 rear-post
brackets, 20 screws, and 2 ear-locking screws
3. Power Cord
4. Console Cable—RJ-45 to DB-9
5. Documentation—Quick Start Guide (this document) and
Safety and Regulatory Information
1
Package Contents
2
3
4
5
Page 2
Quick Start Guide
– 2 –
Verify Switch Operation
1. Verify basic switch operation by checking the system LEDs.
When operating normally, the PSU1/PSU2, Diag, and Fan LEDs should all be on green.
Perform Initial System Boot
1. If the network operating system (NOS) installer is located on a
network server, first connect the RJ-45 Management (Mgmt) port to the network using 100-ohm Category 5, 5e or better twisted­pair cable. (Not required if the NOS installer is located on attached storage.)
2. Boot the switch. Wait for the ONIE software to locate and
execute the NOS installer, and then wait for the installer to load the NOS software image.
Subsequent switch boots will bypass ONIE and directly run the NOS software.
Connect Network Cables
1. For the RJ-45 Management port, connect 100-ohm Category 5,
5e or better twisted-pair cable.
2. Connect DAC cables to the QSFP28 slots. Or first install
QSFP28 transceivers and then connect fiber optic cabling to the transceiver ports.
The following transceivers are supported:
100GBASE-CR4, AOC, SR4, LR4, and PSM4
40GBASE-CR4, SR4, and LR4
3. As connections are made, check the port status LEDs to be sure
the links are valid.
Each QSFP28 port has four LEDs that indicate valid links in the following modes:
1 LED Blue — 100 Gbps mode
1 LED Orange — 40 Gbps mode
1-4 LEDs White — 25 Gbps breakout mode (four lanes)
1-4 LEDs Green — 10 Gbps breakout mode (four lanes)
Note:
For swit c hes with O NIE software pre-loaded, refer to
the network operating system (NOS) installer and NOS documentation for details on software options and set up for ONIE.
415
6
3
2
1
Switch Chassis
Size (WxDxH) 438.4 x 580 x 87.7 mm (17.26 x 22.83 x 3.45 in.)
Weight 14.11 kg (31.1 lb), with two installed PSUs
Temperature Operating: 0° C to 45° C (32° F to 113° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity Operating: 5% to 95% (non-condensing)
Power Consumption
760 Watts maximum
AC PSU
Power Rating 100–240 VAC, 50-60 Hz, 12–6 A, 850 Watts
Regulatory Compliances
Emissions EN 55032:2015+AC:2016, Class A
EN 61000-3-2:2014, Class A EN 61000-3-3:2013 47 CFR FCC Part 15:2015, Subpart B, Class A CE Mark
Immunity EN 55024:2010+A1:2015
IEC 61000-4-2/3/4/5/6/8/11
Safety UL (CSA 22.2 No 60950-1 & UL60950-1)
CB (IEC/EN60950-1)
Hardware Specifications