Eden SOFT-ECM NC, SOFT NC, SOFT RC, SOFT-ECM RC Installation, Operation And Maintenance Manual

|
SOFT
SOFT-ECM
2015-3
Installation, operation
and maintenance manual
It is compulsory to carefully read this Instruction manual before any operation on the machine: serious damages to persons and thinks could occur
if operated by non-qualied personnel.
!
All single components of machine are subject to quality and dimensioning checks during production process.
All maintenance, regulation and replacement operations described in this Instruction manual are to be only performed after stopping and separat-
ing the machine from power supply and hydraulic circuit.
While installation/maintenance operations, the operator must wear protection gloves.
Operator must wear special antiskid and resistant shoes.
Protections have been set up by the Manufacturer in order to physically protect operator while performing its tasks. Do not remove protections for any reason, during operation. If removed must absolutely be restored.
Persons not involved in installation/maintenance operations, if any, should neither transit nor stop close to the operation area.
Electric energy and grounding systems are to be connected by expert and qualied personnel, in compliance with standards in force.
!
It is recommended to protect main power supply line by safety switches (overload switches).
Any magnetic or electromagnetic eld in the nearby could affect proper operation of control panel. Environmental temperature and humidity are the best conditions to properly operate machines.
Ensure that electric circuit is suitably protected and complies with motor characteristics: the machine is equipped with an identication plate, specifying power, frequency and power supply voltage values. Also ensure that grounding has been performed and a differential switch is regularly installed upstream of power supply cable. The Manufacturer is not responsible for damages to persons or things provoked by wrong or unsuitable grounding.
Before performing regulation, maintenance and/or replacement operations, the operator must wait for a time-period after machine stop.
MAIN WARNINGS TO MACHINE USE
Vers. 2015-3
3
INSTALLATION, OPERATION
AND MAINTENANCE MANUAL
water cassette
SOFT / SOFT-ECM
FIRST PART: FOR THE INSTALLER
GENERAL DIMENSIONS FOR 2 PIPE WATER CASSETTES 4
GENERAL DIMENSIONS FOR 4 PIPE WATER CASSETTES 5
WORKING LIMITS 6
GENERAL FEATURES AND MAIN COMPONENTS 6
Structure 6
Heat exchanger 6
Air lter 6
Motor fan group 6
Décor panel 6
Elimination of condensation 6
RECOMMENDATIONS FOR THE INSTALLER 6
Unit installation 6
RECEIVING, STORE AND MOVING THE UNITS 7
INSTALLATION ACCESSORIES 7
SELECTION OF CASSETTE INSTALLATION LOCATION 7
INSTALLATION 7
Fixing the cassette 7
Fixing the panel 7
CHANGE OF AIR AND RECIRCULATION SYSTEM 7
Fresh air renewal 7
WATER CONNECTIONS 8
Standard water connection to heating/cooling system 8
Cassettes with a control board that is managed onboard 8
Cassettes with and without a control board that is managed onboard 8
INSTALLATION OF AUXILIARY DRAIN PAN 8
CONDENSATE DRAINAGE 9
ELECTRICAL CONNECTIONS 9
Access to the control panel 9
WIRING DIAGRAM:
FOR WATER CASSETTE MODEL SOFT NC 10
FOR WATER CASSETTE MODEL SOFT-ECM NC 11
FOR WATER CASSETTE MODEL SOFT RC 12
FOR WATER CASSETTE MODEL SOFT-ECM RC 13
RS485 COMMUNICATION NETWORK 14
WIRING DIAGRAM FOR WATER CASSETTE MODEL SOFT-ECM RC MASTER/SLAVE
15
SECOND PART: FOR THE USER
RECOMMENDATION 16
INFRARED REMOTE CONTROL 17
OPERATION OF INFRARED REMOTE CONTROL 17
Clock adjustment 17
ON/OFF daily timer 17
Emergency ON/OFF button 17
Offset for T1 temperature reading calibration 18
SWING 18
Automatic version 18
Manual version 18
BATTERIES REPLACEMENT 18
EXTRAORDINARY MAINTENANCE 19
END OF SEASON MAINTENANCE 19
WHAT TO DO IF... 19
DISMANTLING THE APPLIANCE 19
INDEX
Vers. 2015-3
4
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
water cassette
SOFT / SOFT-ECM
GENERAL DIMENSIONS FOR 2 PIPE WATER CASSETTES
61 62 63 64 65
Fans number 1 1 1 1 1
Coil numbers 1 1 1 1 1
Hydraulic tting (Ø ISO 228 female gas) Ø 1/2” 1/2” 3/4” 3/4” 3/4”
Air supply in adjacent room (Ø) mm 150 150 150 150 150
Air supply in adjacent room (BxH) mm 300x150 300x150 300x150 300x150 300x150
Fresh air intake (Ø) mm 80 80 80 80 80
Fresh air intake (BxH) mm 100x45 100x45 100x45 100x45 100x45
Unit net weight kg 20 21 23 23 24
Panel net weight kg 3 3 3 3 3
Pic. 01
Vers. 2015-3
5
INSTALLATION, OPERATION
AND MAINTENANCE MANUAL
water cassette
SOFT / SOFT-ECM
GENERAL DIMENSIONS FOR 4 PIPE WATER CASSETTES
81 82 83 83C 84 84C
N. ventilatori 1 1 1 1 1 1
N. batterie 1 1 1 1 1 1
Hydraulic tting (Ø ISO 228
female gas)
standard coil Ø 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
auxiliary coil Ø 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
Air supply in adjacent room (Ø) mm 150 150 150 150 150 150
Air supply in adjacent room (BxH) mm 300x150 300x150 300x150 300x150 300x150 300x150
Fresh air intake (Ø) mm 80 80 80 80 80 80
Fresh air intake (BxH) mm 100x45 100x45 100x45 100x45 100x45 100x45
Unit net weight kg 23 24 24 24 24 24
Panel net weight kg 3 3 3 3 3 3
Pic. 02
Vers. 2015-3
6
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
water cassette
SOFT / SOFT-ECM
WORKING LIMITS
RECCOMENDATIONS FOR THE INSTALLER
GENERAL FEATURES AND MAIN COMPONENTS
SUMMER (COOLING)
Minimum inlet water temperature +4°C
Maximum operating pressure 8 bar
Maximum room air temperature +35°C
Maximum room air humidity 80%
WINTER (HEATING)
Maximum inlet water temperature +70°C
Maximum operating pressure 8 bar
Minimum room air temperature +4°C
Maximum room air humidity 80%
Maximum room air temperature +35°C
ATTENTION!
Air stratication increases with the raise of inlet water temperature!
The units have the following operating limits:
- it can’t be installed in areas with anomalous heat and humidity conditions
- it can’t be installed outdoors
- it can’t be installed in explosive environments
- it can’t be installed in a corrosive atmosphere
1 Airow direction louvers
2 Air intake grille with lter
3 Electric box 4 Fixing brackets
STRUCTURE
Made in heavy-gauge galvanised sheet, the structure comes complete with ex-
ternal brackets on the two sides for easy xing to the ceiling. Thermal-acoustic insulation lining in polystyrene.
Set-up for distribution of air to adjacent rooms through knock-out holes, either
circular Ø 150 mm or rectangular 350x100 mm, located on two sides of the appliance. Set-up for external air intake through Ø 80 mm circular knock-out hole.
HEAT EXCHANGER
Coil in copper piping expanded into aluminium ns in continuous block. The headers have easily accessible female gas ttings and air vent/drainage valve.
AIR FILTER
The lter comprises a galvanized steel frame holding the ltering membrane. In­serted in the inner part of the front panel, it may be easily removed and cleaned
using a vacuum cleaner followed by washing with water.
GRUPPO ELETTROVENTILANTE
Single-inlet centrifugal fan with statically and dynamically balanced plastic im­peller. The electric motor, made to international standards, has an overload cut- out and the run capacitor always connected. The motor is directly coupled to the
fan and cushioned with exible mountings. It is particularly efcient and low noise.
DÉCOR PANEL
The décor panel has an innovative design so that the appliance may be used in both residential and commercial premises. The white (RAL 9010) panel is made in SOFTweight but strong plastic. Fixing to the load-bearing structure is quick and easy. 4 adjustable louvers ensure best air distribution throughout the room. Central intake grille with lter for cleaning the air. The grille may be removed to access internal parts without having to remove the panel from the ceiling.
ELIMINATION OF CONDENSATION
Condensate collecting system comprising:
- internal plastic tray for collecting condensation coming from the heat exchanger;
- external auxiliary plastic tray for collecting condensation coming from the
valves and connecting pipes.
- electric pump, which is an integral part of the appliance and connected
to the external tting..
Upon receiving the unit check for any damage, which should be reported imme-
diately. For the water cassette to operate correctly, it should be installed accor­ding to the instructions given in this manual. Removal of a water cassette after it
has been installed is an operation that requires special training: if this is neces-
sary, please consult your dealer. After installation, explain the correct operating procedure to the customer using the booklet as a reference. Leave this manual with the customer since it is part of the kit supplied with the appliance. Take care not to scratch the units when handling them.
UNIT INSTALLATION
- Read this instruction manual thoroughly before starting installation.
- This unit complies with the low-voltage (EEC/73/23) and electromagnetic com­patibly (EEC/89/336) directives.
- The installation should be carried out by a qualied installer.
- Follow all current national safety code requirements. In particular ensure that a properly sized and connected ground wire is in place.
- Check that the voltage and frequency of the mains power supply are as requi­red for the unit to be installed; the available power source must be adequate to
operate all other appliances connected to the same line.
- Ensure that national safety code requirements have been followed the main
supply circuit.
- Where necessary, use eld-supplied 25 mm I.D. PVC pipe of appropriate leng­th and with the correct thermal insulation for the condensate drain extension.
- After installation thoroughly test system operation and explain all system fun-
ctions to the owner.
Pic. 03
WARNING!
- Disconnect the mains power supply switch before servicing the system or handling any internal parts of the unit.
- The manufacturer declines any liability for damage resulting from modi­cations or errors in the electrical or water connections.
- Failure to observe the installation instructions, or use the unit under conditions other than those indicated in table “Operating limits” of this manual, will immediately invalidate the unit warranty.
- Failure to observe electric safety codes may cause a re hazard in the event of short circuits.
- Do not install or use damaged units.
- In case of malfunction turn the unit off, disconnect the mains power sup­ply and contact a qualied service engineer.
- Maintenance must only be carried out by qualied personnel.
- All of the manufacturing and packaging materials used for this appliance are biodegradable and recyclable.
- Dispose of the packaging material in accordance with local require­ments.
1
2
3
4
Vers. 2015-3
7
INSTALLATION, OPERATION
AND MAINTENANCE MANUAL
water cassette
SOFT / SOFT-ECM
RECEIVING, STORE AND MOVING THE UNITS
INSTALLATION ACCESSORIES
SELECTION OF CASSETTE INSTALLATION LOCATION
At the moment of the delivery of the unit, make sure that it corresponds to the
one indicated on the transport document. Check the integrity of the packing and the unit. Should there be any differences with the original order or any
damages, anomalies, or incomplete supply, please point it out on the delivery
note and inform the rm straight away. Never install or use damaged appara­tuses. The unit can be stored in room protected from bad weather with tem­perature between the +4°C and the +40°C. Transport the packed unit near as possible to the installation place. To avoid any damage to the unit, the plastic part (frontal panel and grille) are furnished separately. The handling and the installation could be facilitated cy use of an elevator (Pic. 04).
Is included in the delivery nr. 1 cardboard mounting template to position the unit during the installation phase.
RECCOMENDATION!
- The unit must be installed in a solid and vibration-free ceiling.
- There should be no obstruction of the air ow into and out of the unit and the air should be evenly distributed throughout the whole room.
- Do not install the unit near sources of heat, steam or inammable gases.
- Install the unit near an electric socket or connect it directly to the power
supply.
- Do not install the unit in a place, which is exposed to direct sunSOFT.
- The selected place should allow easy drainage of the condensed water.
- Periodically check appliance operation and leave sufcient space for mainte­nance around the appliance, as shown in the picture 05.
- Install the unit so that the lter is easily accessible.
FIXING THE PANEL
After installation of the unit, mount the grille using the 4 screws provided
(pic. 09).
ATTENTION: It is very important to x the grille in the right position for correct connection of the receiver panel to the unit.
Establish the position and size of the hole in the ceiling using the cardboard mounting template (pic. 06).
To x the unit to the ceiling, use the threaded bar and suitable screw anchors as shown in pic. 07 (material not included in the supply).
Use a spirit level (Pic. 08), to make sure that the unit is level and check that it is securely xed to the ceiling. In high humidity environments, metal supports must be insulated using adhesive insulating material.
Pic. 04
Pic. 05
Pic. 06
Pic. 07
Pic. 08
Pic. 09
ATTENTION!
Catch up the cassette on the four corners. Don’t lift or move the unit through the ex-
changer pipelines or the exhaust pipe con-
dense.
INSTALLATION
FIXING THE CASSETTE
Select a place of installation where there can be a clearance of a least 140 cm (see pic. 05) around the appliance. Make sure that the installation does not
interfere with existing electric wiring or plumbing.
- To x the panel only use the 4 supplied screws. Do not use other kinds of screws or you could damage the condensate drain pan.
- Do not bend or narrow the unit piping.
- Do not remove the cap from the unit piping until immediately before connecting the pipes.
- To prevent deformation of the air intake grille, do not overtighten the screws.
B
A
C
D
>140
100 < H > 350
610 m
m
300 m
m
CHANGE OF AIR AND RECIRCULATION SYSTEM
- Side knockouts allow connection of a duct for fresh air intake and for conditio-
ning an adjacent room.
- Remove the external prepunched anti-condensate insulator and remove the
knockout panels using a punch.
FRESH AIR RENEWAL
Remove the knockout holes and the insulation. The ducts may be in exible po­lyester (with steel spiral core) or in corrugated aluminium lagged with anti-con­densate material (breglass 12±25 mm thick). Upon completion of installation, surfaces that have not been insulated may be covered with anti-condensate
insulating material (e.g.: 6 mm thick expanded neoprene).
Failure to comply with these instructions could cause dripping due to the condensate; the manufacturer cannot be held responsible for any damage.
Vers. 2015-3
8
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
water cassette
SOFT / SOFT-ECM
WATER CONNECTIONS
The following reasons explain why it is necessary to install the 3-way valve:
- Cassettes with a control board onboard
1) If the water ow is not closed via the valve when the room temperature is
reached, the air sensor installed in intake mode is conditioned by the heat ex-
changer that cools it or heats it via natural convection. The result is that the unit will not adjust the temperature correctly or it will not go on.
2) The unit has a protection system that intervenes by closing the water ow via
the valve in cases such as: a) Where there is a condensate discharge problem (if the valve does not close
the water ow, the battery will continue to condense, causing the condensation basin to overow). b) The user inserts the incorrect function on the remote control: hot as op­posed to cold. c) The water temperature rises to 80 °C (which damages the main conden-
sation basin)
3) The unit has been designed to have continuous ventilation and warm or cool the room by closing or opening the water ow: this allows for optimal adjustment inside the room where it is installed.
- Cassettes with and without a control board onboard
4) If the unit remains turned off for a long time in cooling mode and the water
ow is not closed, droplets of condensation may form at the air outlets, which will subsequently lead to a dripping unit.
ATTENTION!
- Always use suitably sized wrenches to x or slacken the water pipes.
- It is essential to insulate pipes, valves and connections correctly in order toavoid the formation of condensation, which could drip into suspended ceilings causing considerable problems.
The water connections are xed to the unit body to avoid damage when pi­pes are connected. It is advisable to tighten the connection with a wrench. The upper coil connection is tted with an air valve and the lower connection with a drain valve, suitable for a 10 mm wrench or screwdriver. (The coil is only
partially drainable; it is advisable to blow air into the coil for complete drainage)
STANDARD WATER CONNECTION TO HEATING/ COOLING SYSTEM
ATTENTION! IT IS COMPULSORY TO INSTALL THE VALVE!
For air supply to an adjacent room and fresh air intake remove sheet knockout
holes anr the insulation.
ATTENTION!
Ducting air to an adjacent room requires the closure of at least the corre­sponding duct end.
Pic. 10
Pic. 11
Pic. 12
A Knockout for air supply to an adjacent room Ø 150 mm
B Knockout for air supply to an adjacent room 350x100 mm
C (ACCESSORY) Ø 80 mm circular spigot for fresh air intake
D Knockout for fresh air intake 100x45 mm
A
B
D
C
C
OUT
IN
OUT OUT
ININ
Balancing valve
Shut off valve
3-way valve
INSTALLATION OF AUXILIARY DRAIN PAN
a) Remove the plastic cap from the condensate drain outlet on the water
cassette. Do NOT push the cap into the cassette. Fit the nozzle into the hole (auxiliary condensate drain pan outlet).
b) Fix the auxiliary drain pan to the unit using the relative screws provided in the
kit, ensuring that the condensate pan is level.
Pic. 14
Pic. 13
OUT
OUT
IN
IN