Edelbrock Qwikdata 91195, Qwikdata 91196 User Manual

Edelbrock Qwikdata Shaft Speed Sensor Kit
Catalog # 91195 & 91196
PLEASE study these instructions carefully before installing your new Edelbrock Qwikdata Shaft Speed Sensor Kit. If you have any questions or problems, do not hesitate to contact our Technical Hotline at: 1-800-416-8628, from 7am-5pm, Monday through Friday, Pacific Standard Time, or via e-mail at: Edelbrock@Edelbrock.com.
DESCRIPTION The Edelbrock Qwikdata Shaft Speed Sensor Kit allows users of the Qwikdata data aquisition system or other data aquisition systems to mount up to 4 magnets in an aluminum ring to the rear end pinion yoke on a Ford 9” housing. Part #91195 will mount to most standard Ford 9” rear housings with a 1.875” diameter pinion yoke. Part #91196 will fit 2.187” diameter, 35 spline yokes.
Installation Procedure
Note: Refer to Figure 1 below for reference on all steps.
1. Install the number of magnets you require for your data aquisition system into the ring assembly.
2. The magnets are to be seated against the shoulder (towards the outside diameter of the ring), then glued with an adhesive such as epoxy, RTV silicone, hot glue, etc. (Note: Some
computers are sensitive to the magnet’s north and south poles. Install magnets per requirements for your data aquisition system.)
3. Install the ring halves around the pinion coupler and tighten the 10-32 x 3/4” cap screws tightly. The beveled edge of the
Kit Contents: 1 - Two-Piece Aluminum Mounting Ring 2 - 10-32 x 3/4” Cap Screws 4 - Magnets 1 - Sensor Switch Bracket 1 - Sensor Switch
inside of the ring should face the pinion U-joint. The gap on each side of the ring should be even to ensure correct timing on multiple magnet use.
4. Attach the Sensor Switch Bracket to a bolt or stud on the rear end housing as shown in Figure 1. Attach Sensor Switch and adjust gap to .060”-.100” for Qwikdata use, or to your data aquisition system specification.
Note: Periodically, make sure the magnets and mounting ring
are secure.
Caution: Excessive heat can cause the magnets to lose power.
Set gap at .060”-.100” for
Qwikdata use
OR
Set gap per data aquisition system
per manufacturer’s instructions
Beveled edge should face Pinion U-Joint
FIGURE 1
©2003 Edelbrock Corporation
Use a washer .060”-.080” thick to prevent interference with the pinion support radius
Tighten so that the
gaps are even
Fill cavities with
Grip Diameter
Be sure the magnets are
seated against the outside
shoulder of the ring
Note: Some multi-magnet sensors are pole-sensitive and must be installed in correct +/- sequence.
epoxy or silicone
to secure magnets
Edelbrock Corporation, 2700 California Street, Torrance, CA 90503
Tech Line: 800-416-8628; Office: 310-781-2222