Edelbrock 71900 User Manual

www.edelbrock.com
Page 1 of 17
Please study these instructions carefully before installing your new Progressive Nitrous Contoller. If you have any questions, please contact our Technical Hotline at : 1-800-416-8628 from 7 am - 5pm, Monday-Friday, Pacific Standard Time or e-mail us at Edelbrock@Edelbrock.com
.
Important Information - You must use Static Suppression Ignition Wires with this controller. The
71900 Progressive Nitrous Controller contains high frequency digital electronics and will NOT function correctly without suppression wires.
Warning -
Do not mount the progressive controller anywhere near ignition components or any other
source of electronic noise.
Notice - The controller must be grounded directly to the vehicle’s battery.
Caution - Do not submerge the controller in liquid or directly wash the unit with liquid of any type! Warning - The programming switches are delicate electronic items and can be damaged by misuse
and/or carelessness. If the controller is close to your nitrous bottle, be careful when installing the bottle. The weight of the bottle is enough to easily damage the switches. Switches that have been determined to be damaged due to neglect will NOT be covered under warranty.
Notice:
It is the responsibility of the purchaser to follow all guidelines and safety procedures supplied with this product and any other manufactures product used with this product. If is also the responsibility of the purchaser to determine compatibility of this device with the vehicle and other components.
Edelbrock Corporation assumes no responsibility for damages resulting from accident, improper installation, misuse, abuse, improper operation, lack of reasonable care, or all previously stated reasons due to incompatibility with other manufacturer’s products.
Edelbrock Corporation assumes no responsibility or liability for damages incurred fron the use of products manufactured or sold by Edelbrock Corporation on vehicles used for competition racing.
Edelbrock Corporation neither recommends nor approves the use of products manufactured or sold by Edelbrock Corporation on vehicles which may be driven on public highways or roads, and assumes no responsibility for damages incurred from such use.
It is the purchaser’s responsibility to check the state and local laws pertaining to the use of Nitrous Oxide for racing applications. Edelbrock Corporation does not recommend nor condone the use of its products for illegal street racing.
Installation of this Edelbrock product signifies that you have read this document and agree to the terms stated within.
Caution:
Follow all recommended safety guidelines from this and other manufacturer’s installation guides. Never install any device which pulsates nitrous solenoids without a safety solenoid installed. Static Suppression ignition wires must be used with this unit! Mount the unit as far away from secondary ignition components (coil, ignition wires, etc.) as physically possible.
©2008 Edelbrock Corporation Catalog #71900
Brochure #63-0473
Rev. 08/08 - AJ/mc
Catalog #71900
Progressive Nitrous Controller
www.edelbrock.com
Page 2 of 17
71900 - Progressive Nitrous Controller
The 71900 Progressive Nitrous Controller was designed using the latest digital technology available. The result is a controller which is extremely accurate and user-friendly. A simple and functional programming interface allows the user to set important nitrous parameters in a matter of seconds, all without the use of external programmers or computers. An Options Menu has been included to enable the user to customize the controller for a particular application. The Options Menu also contains a function that if selected will return the contoller to its original factory Pre-Programmed state.
Features:
Full Digital Circuitr
y:
This design approach assures the best in performance and reliability.
Digital technology provides extremely accurate control that cannot be achieved with analog systems.
Easy to Read LED Display with Touch Switch Programming: This user
interface is very user-friendly and provides quick and accurate programming of the progressive nitrous controller.
Integrated Batter
y Voltage Monitor:
The battery voltage is displayed periodically on
the LED display.
Non-Volatile Data Memory: No battery or power connection is needed to retain the
controllers parameter settings. There is no need to re-program the controller after the battery is disconnected. There is NO internal battery, all data is stored in flash memory and will be retained for up to 10 years with no power applied to the controller.
Separate Nitrous and Fuel Solenoid Outputs: This design provides more output
current capability. By using separate outputs, better control of the solenoid is achieved. The response of the nitrous system is improved and much more accurate. The fuel output is programmed to function as though the fuel and nitrous solenoids were on the same output terminal. The Options Menu allows the user to program the fuel solenoid to operate in full progressive mode (i.e. - The fuel solenoid will pulse through the entire progression).
+12 Volt Timer Output: A digital timer is provided that can be used to activate an ignition retard
controller or a 2nd stage of nitrous. The output from activation terminal is on (+12 volt applied). If the activation signal is removed, the +12V timer will halt until the signal is re-applied. The +12v timer can be programmed from
0.000 to 9.999 seconds. The Options Menu allows the user to configure the timer output behavior while the controller is in the activated state. Optionally, the output can be configured to remain ON regardless of the activation input. NOTE - Setting the timer to 0.000 will disable the timer output.
©2008 Edelbrock Corporation Catalog #71900
Brochure #63-0473
Rev. 08/08 - AJ/mc
www.edelbrock.com
Page 3 of 17
Nitrous Delay Timer: A digital timer is provided that can be used to delay the start of the nitrous.
This timer begins counting down when the activation terminal is on (+12v applied). If the activation signal is removed, the delay timer will halt until the signal is re-applied. The delay timer can be programmed from 0.000 to 9.999 seconds.
Nitrous Starting Percentage: The user can program the amount of nitrous power that will
be applied after the nitrous delay timer has elapsed (Immediately if delay timer is set at 0.000). This parameter is set as a percentage and can range from 10% to 100%. If the starting power is more than the ending power, the nitrous power will decrease with time.
Final Nitrous Percentage: This setting allows the user to program how much nitrous power
is applied after the nitrous ramp has completed. This parameter is also set as a percentage and can range from 10% to 100%. By setting the final power percentage less than the starting percentage, the user can back off the nitrous power.
The Options Menu allows the user to select a single or dual ramp nitrous power ramp. When the dual ramp mode is selected, there will be two final percents and two power ramp times.
Nitrous Power Ramp Time: The power ramp time is used to determine the rate at which
the nitrous power goes from the start percentage to the final percentage. The nitrous power ramp time can be set from .200 to 9.900 seconds.
The Options Menu allows the user to select a single or dual ramp nitrous power ramp. When the dual ramp mode is selected, there will be two final percents and two power ramp times.
Intelligent Nitrous Progressive Timer: The progressive nitrous timer system will wait
at its present state if the activation signal is removed. Nitrous progression will resume when the controller is re­activated. The entire nitrous and +12 volt timer system is automatically reset 20 seconds after activation.
Optionally the nitrous timer system can be configured to RESET each time the activation signal is applied. This method would allow the nitrous power to be applied with each gear change or each time the throttle is lifted and re-applied. This feature is selected with the Options Menu.
An added feature has been included to the timer system to help the user tune the nitrous power ramp. When the timer system is activated (+12v at the activation input) an internal timer is started which will record the time and percent of the progressive cycle when the activation signal is removed. This data can be used to determine at what point in the progressive cycle that the power ramp is too aggressive and the driver is lifting the throttle.
©2008 Edelbrock Corporation Catalog #71900
Brochure #63-0473
Rev. 08/08 - AJ/mc
www.edelbrock.com
Page 4 of 17
TABLE OF CONTENTS
Page #
Programming
+12 Volt Timer. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Nitrous Delay Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Nitrous Starting Percentage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Nitrous Ending Percentage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Nitrous Power Ramp Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Example Nitrous Power Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Options Menu, Programming
Viewing Run Data and Entering the Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Clearing Run Data (Reset for Next Run) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Resetting Controller to Factory Default . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Calibrating the Voltage Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Setting the Dual Nitrous Power Ramp ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Setting Progressive Fuel Output ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Setting Activation Wait and Hold ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Setting +12V Timer Output Hold ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Enabling Quick Data Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Setting the RESET Timeout Period . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Exiting the Options Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Using the Dual Ramp Feature
How the Dual Power Ramp Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Example Dual Ramp Nitrous Power Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installation
Items Included with 71900 Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Items Needed that are NOT Supplied . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Cautions and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Technical Information
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
©2008 Edelbrock Corporation Catalog #71900
Brochure #63-0473
Rev. 08/08 - AJ/mc
www.edelbrock.com
Page 5 of 17
Programming the +12 Volt Timer
Press and release the FUNCTION switch until the message “+12V Timer Delay” appears on the display. After the function message has scrolled across the display, the current +12 Volt Timer setting will appear on the display.
To adjust the +12 volt timer value, press the desired digit button and the value of that digit will increment. The digit will roll over to 0 and begin counting up again if the user continues to release and press the digit button.
To exit without saving the new value, press the FUNCTION switch and select another function.
To save the new value, press and release the ENTER switch and the display will read “SAVED” and the new setting is now saved.
The range of the +12 volt timer is 0.000 to 9.999 seconds with a .001 second resolution.
This setting will determine the amount of time in seconds before the +12 volt timer output becomes active (goes to +12V) after controller activation.
NOTE - Setting timer to 0.000 will disable the +12V timer output. Set to 0.001 for quick activation.
Programming the Nitrous Delay Timer
Press and release the FUNCTION switch until the message “Nitrous Delay Timer” appears on the display. After the function message has scrolled across the display, the current Nitrous Delay Time setting will appear on the display.
To adjust the nitrous delay timer value, press the desired digit button and the value of that digit will increment. The digit will roll over to 0 and begin counting up again if the user continues to release and press the digit button.
To exit without saving the new value, press the FUNCTION switch and select another function.
To save the new value, press and release the ENTER switch and the display will read “SAVED” and the new setting is now saved.
The range of the +12 volt timer is 0.000 to 9.999 seconds with a .001 second resolution.
This setting will determine the amount of time in seconds before the nitrous becomes active (nitrous begins at starting percentage) after controller activation.
©2008 Edelbrock Corporation Catalog #71900
Brochure #63-0473
Rev. 08/08 - AJ/mc
www.edelbrock.com
Page 6 of 17
Programming the Nitrous Starting Percentage
Press and release the FUNCTION switch until the message “Starting Percentage” appears on the display. After the function message has scrolled across the display, the current nitrous starting percentage setting will appear on the display.
To adjust the nitrous starting percentage value, press the desired digit button and the value of that digit will increment. The digit will roll over to 0 and begin counting up again if the user continues to release and press the digit button. If the .1 digit button is pressed, the starting percentage will go to 100%, pressing again will set the starting percentage back to 0%. The 1. digit is ignored for this function.
To exit without saving the new value, press the FUNCTION switch and select another function.
To save the new value, press and release the ENTER switch and the display will read “SAVED” and the new setting is now saved.
The range of nitrous starting percentage is 10% to 100% in 1% increments.
This setting will determine the amount of nitrous to be applied after the nitrous delay timer has elapsed.
Programming the Final Nitrous Percentage
NOTE - If the dual ramp feature is enabled fron the options menu, there will be a “Final Percent #2” in the
menu list. The programming method is the same as the “Final Percent #1”. Please refer to the section “Options Menu” and “Using the Dual Ramp Feature” for more information.
Press and release the FUNCTION switch until the message “Final Percent #1” appears on the display. After the function message has scrolled across the display, the current final nitrous percentage setting will appear on the display.
To adjust the final nitrous percentage value, press the desired digit button and the value of that digit will increment. The digit will roll over to 0 and begin counting up again if the user continues to release and press the digit button. If the .1 digit button is pressed, the final percentage will go to 100%, pressing again will set the starting percentage back to 0%. The 1. digit is ignored for this function.
To exit without saving the new value, press the FUNCTION switch and select another function.
To save the new value, press and release the ENTER switch and the display will read “SAVED” and the new setting is now saved.
The range of the nitrous final percentage is 10% to 100% in 1% increments.
This setting will determine the amount of nitrous to be applied at the end of the nitrous power ramp time.
©2008 Edelbrock Corporation Catalog #71900
Brochure #63-0473
Rev. 08/08 - AJ/mc
Loading...
+ 11 hidden pages