2.50 101 14.69 0.00 0.00
2.60 106 15.43 0.73 1.50
2.70 111 16.16 1.47 2.99
2.80 116 16.90 2.20 4.49
2.90 122 17.63 2.94 5.98
3.00 127 18.37 3.67 7.48
3.10 132 19.10 4.41 8.97
3.20 137 19.83 5.14 10.47
3.30 142 20.57 5.88 11.97
3.40 147 21.30 6.61 13.46
3.50 152 22.04 7.35 14.96
3.60 157 22.77 8.08 16.45
3.70 162 23.51 8.82 17.95
3.80 167 24.24 9.55 19.44
3.90 172 24.98 10.28 20.94
4.00 177 25.71 11.02 22.44
4.10 182 26.45 11.75 23.93
4.20 187 27.18 12.49 25.43
4.30 192 27.92 13.22 26.92
4.40 198 28.65 13.96 28.42
4.50 203 29.38 14.69 29.91
Output Volts kPa PSIa PSIg in/Hg
0.50 0 0.00 -14.69 -29.91
0.60 5 0.73 -13.96 -28.42
0.70 10 1.47 -13.22 -26.92
0.80 15 2.20 -12.49 -25.43
0.90 20 2.94 -11.75 -23.93
1.00 25 3.67 -11.02 -22.44
1.10 30 4.41 -10.28 -20.94
1.20 35 5.14 -9.55 -19.44
1.30 41 5.88 -8.82 -17.95
1.40 46 6.61 -8.08 -16.45
1.50 51 7.35 -7.35 -14.96
1.60 56 8.08 -6.61 -13.46
1.70 61 8.82 -5.88 -11.97
1.80 66 9.55 -5.14 -10.47
1.90 71 10.28 -4.41 -8.97
2.00 76 11.02 -3.67 -7.48
2.10 81 11.75 -2.94 -5.98
2.20 86 12.49 -2.20 -4.49
2.30 91 13.22 -1.47 -2.99
2.40 96 13.96 -0.73 -1.50
36020 - 2-BAR Manifold Absolute Pressure Sensor
2.50 446.0 50.00
2.60 463.3 52.50
2.70 480.5 55.00
2.80 497.7 57.50
2.90 515.0 60.00
3.00 532.2 62.50
3.10 549.4 65.00
3.20 566.7 67.50
3.30 583.9 70.00
3.40 601.2 72.50
3.50 618.4 75.00
3.60 635.6 77.50
3.70 652.9 80.00
3.80 670.1 82.50
3.90 687.3 85.00
4.00 704.6 87.50
4.10 721.8 90.00
4.20 739.1 92.50
4.30 756.3 95.00
4.40 773.5 97.50
4.50 790.8 100.00
Output Volts kPa PSIg
0.50 101.3 0.00
0.60 118.5 2.50
0.70 135.8 5.00
0.80 153.0 7.50
0.90 170.2 10.00
1.00 187.5 12.50
1.10 204.7 15.00
1.20 222.0 17.50
1.30 239.2 20.00
1.40 256.4 22.50
1.50 273.7 25.00
1.60 290.9 27.50
1.70 308.1 30.00
1.80 325.4 32.50
1.90 342.6 35.00
2.00 359.8 37.50
2.10 377.1 40.00
2.20 394.3 42.50
2.30 411.6 45.00
2.40 428.8 47.50
36011 - 0-100 PSI Pressure Sensor
SENSOR CALIBRATION:
Edelbrock Pressure Sensors are pre-calibrated for use with Edelbrock Pro-Tuner software. If you are using another aftermarket ECU system, you will
need to calibrate the sensors using your software. Refer to the following charts and enter the values required by your software to calibrate the sensors
to your software.