Ecube Labs CFX User Manual

CleanFLEX
Installation and Activation
English v1.0.0
Copyright © 2018 Ecube Labs Co., Ltd. All Rights Reserved - Proprietary and Confidential.
CleanFLEX installation and Activation
- 2 -
Legal Notices
Trademarks
Ecube Labs, CleanCUBE, CleanCAP, CleanFLEX and CleanCityNetworks are trademarks
of Ecube Labs Co., Ltd. In this user manual, Ecube Labs®, CleanCUBE®, CleanCAP®,
CleanFLEX® and CleanCityNetworks® are referred to as Ecube Labs, CleanCUBE,
CleanCAP, CleanFLEX and CleanCityNetworks (CCN) respectively.
Copyright
Copyright © 2018 Ecube Labs Co., Ltd. All rights reserved.
No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval
system, or translated into any language or computer language, in any form or by any means,
electronic, mechanical, magnetic, optical, chemical, manual, or otherwise, without the prior
written permission of Ecube Labs Co., Ltd.
Notice
This user manual is provided for informational purposes only.
All information included herein is subject to change without notice. Ecube Labs makes no
warranty of any kind with regard to this user manual, either expressed or implied, except as
provided herein, including without limitation, thereof, warranties as to marketability,
merchantability, fitness for a particular purpose of use or against infringement of any patent.
Ecube Labs shall not be responsible for any direct, incidental, or consequential damages of
any nature, or losses or expenses resulting from the use of this user manual.
CleanFLEX installation and Activation
- 3 -
Table of Contents
1. Introduction to CleanFLEX ......................................................... 4
1.1 CleanFLEX contents ........................................................................ 4
1.1.1 Included in CleanFLEX box ...................................................... 4
1.1.2 Optional with CleanFLEX .......................................................... 5
1.2 Technical specification ..................................................................... 5
1.3 Features............................................................................................ 6
2. Installing CleanFLEX .................................................................. 7
2.1 Installation prerequisites ................................................................... 7
2.2 Installing CleanFLEX ........................................................................ 8
3. Activating CleanFLEX ............................................................... 10
3.1 Checking CleanFLEX ON/OFF status ........................................... 10
3.2 Turning CleanFLEX ON ................................................................. 10
3.2.1 Prerequisites ........................................................................... 10
3.3 Turning CleanFLEX OFF ............................................................... 12
4. Bin profile .................................................................................. 14
4.1 Placing liner bag inside the waste bin ......................................... 14
5. Customer support...................................................................... 16
5.1 Fill-level measurement issues ....................................................... 16
5.2 Telecommunication and Battery issues ........................................ 16
6. Regulatory Notices .................................................................... 17
CleanFLEX installation and Activation
- 4 -
1. Introduction to CleanFLEX
CleanFLEX is a smart ultrasonic fill-level sensor that can be easily installed on any type of
container. It uses robust ultrasonic technology, allowing it to monitor any type of substance.
CleanFLEX measures bin fill-level, monitors bin status, and sends real-time data to
CleanCityNetworks (CCN). CleanFLEX telecommunicates with CCN through WCDMA
networks. Obtaining real-time fill-level data of bins allows you to take action ahead of time.
1.1 CleanFLEX contents
When you receive CleanFLEX, ensure that you have all items mentioned in this section.
1.1.1 Included in CleanFLEX box
Each CleanFLEX box is shipped with the following items:
CleanFLEX (1 EA)
M6×12mm (2 EA), M6×8mm (2 EA)
Magnet (1 EA) Torx driver (1 EA), Torx bit M3 (1 EA), Torx bit M6 (1 EA)
CleanFLEX installation and Activation
- 5 -
1.1.2 Optional with CleanFLEX
In certain cases, optional items (e.g. brackets) are required for installing CleanFLEX inside
a waste container. These items are customized to fit your waste containers and must be
ordered separately. Before ordering these items separately, you must provide information
about height, width, volume, and material of your waste container. Based on information
provided, Ecube Labs will calculate the exact height for installing CleanFLEX and will
provide appropriate bracket and kit for installing CleanFLEX inside the waste containers.
1.2 Technical specification
The technical specifications of CleanFLEX are shown in the following table.
Specification
Description
Sensor parameter
Technology
Ultrasonic
Range
2 – 400 cm (~1” - ~157”)
Resolution
1 cm (0.4”)
Data
management Accessibility
24/7 access through CleanCityNetworks (CCN)
mobile and web interface
Types
Container fill-level, container internal
temperature (optional), GPS coordinates
Software
Settings are configurable remotely
Communication WCDMA
850/1900 MHz
Network
Internal SIM card
Dimensions Size (L×W×H)
80×85×52 mm
Weight
300 g
Power
Battery Type
Replaceable 3.6V high performance lithium
battery
1
Battery Life
Approx. 5 years2
Physical
Characteristics Material
Shockproof ABS/Polycarbonate
Additional
installation parts
Mounting bracket, external antenna
Radio Spec
Frequency
USA/Canada: 1850 ~ 1910MHz, 824 ~
CleanFLEX installation and Activation
- 6 -
849MHz
RF Power
USA/Canada: 23.5dBm, 24dBm
1
: Use of undesignated battery may affect product life, and performance.
2
: Battery life assuming four transmissions per day with acceptable local network quality
1.3 Features
CleanFLEX provides the following features:
˙ Mountable to any type of bin or container.
˙ It is complementary to CleanCUBE and can be installed in areas not feasible for CleanCUBE
installations.
˙ Data from CleanFLEX can be viewed on the same software solution that displays data from
CleanCUBE.
˙ Provides accurate sensing with ultrasonic technology.
˙ Effectively monitors both solid materials and liquids.
˙ Allows you to configure sensors remotely.
˙ Provides real-time wireless transmission of bin fill-level and bin status data to CleanCityNetworks.
˙ Telecommunication on WCDMA networks are supported.
˙ Provides location information through GPS module.