ECS HC-49USX-DN Data Sheet

-40 to +85°C Temp Range Industry Std. Footprint Pb Free/RoHS Compliant
OPERATING CONDITIONS / ELECTRICAL CHARACTERISTICS
PARAMETERS CONDITIONS
Frequency Range Frequency Tolerance Frequency Stability Shunt Capacitance Load Capacitance (CL) Drive Level Operating Temperature Storage Temperature Aging (Per Year)
fo
at +25°C
-40 to +85°C Co
Specify in P/N
@ +25°C ±3°C
HC-49USX-DN
MIN TYP
3.57
10
-40
-55
EQUIVALENT SERIES RESISTANCE/MODE OF OSCILLATION
HC-49USX-DN
QUARTZ CRYSTAL
The HC-49USX-DN is the industrial temperature range version of our standard HC-49USX crystal.
UNITS
MHz ppm ppm
pF pF
µW
°C °C
ppm
20
MAX
70.000 ± 30
± 100
7
Series
500 +85
+125
±5
3.57 ~ 3.999
4.000 ~ 4.999
5.000 ~ 5.999
6.000 ~ 6.999
7.000 ~ 8.999
Fundamental Fundamental Fundamental Fundamental Fundamental
MAX ESR
200 150 120 100
80
9.000 ~ 12.999
13.000 ~ 19.999
20.000 ~ 30.000
27.000 ~ 70.000
Fundamental Fundamental Fundamental 3rd Overtone
60 40 30
100
PACKAGE DIMENSIONS (mm)
Height "H" MAX
3.5 mm
-4X
-4LX
2.5 mm
Figure 1) Side and Top views
PART NUMBERING GUIDE: Example ECS-200-20-4XDN
ECS - Frequency Abbreviation - Load Capacitance - Package Stability Temperature
20 =20 pF
See P/N Guide
1105 South Ridgeview Road z Olathe, KS 66062 z Phone: 913.782.7787 z Fax: 913.782.6991 z www.ecsxtal.com
S=Series
4X =
HC-49USX
D= ± 100 ppm N= -40 ~ +85°C200 = 20.000 MHz