ECS DV25IN33L-1, DV33IN33LP-1, DV25IN33LN-1, DV35IN33L-1, DV35IN33LN-1 Installation Instructions And Owner's Manual

...
INSTALLATION INSTRUCTIONS
GAS-FIRED
AND
OWNER’S MANUAL
INNSBROOK FIREPLACE INSERT
Installer: Leave this manual with the appli-
ance.
Consumer: Retain this manual for future refer-
ence.
DIRECT VENT
GAS FIREPLACE HEATER
MODEL SERIES
UL FILE NO. MH30033
WARNING: If the information in these instruc­tions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppli­er’s instructions.
If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by state or local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
WARNING: If not installed, operated and main­tained in accordance with the manufacturer’s instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.
Page 1
TABLE OF CONTENTS
SECTION PAGE
Important Safety Information .................................................................................................3
Safety Information for Users of LP Gas .................................................................................4
Introduction ............................................................................................................................5
Specifications .........................................................................................................................6
Fireplace Insert Dimensions ...................................................................................................7
Mantle and Trim Clearances ..................................................................................................8
Gas Supply .............................................................................................................................9
Venting and Installation .................................................................................................. 10-12
Vertical Termination .............................................................................................................13
Alternate ON/OFF Switch Installation .................................................................................14
Surround Panel Installation ..................................................................................................15
Blower Accessory Information .............................................................................................16
Log Placement ......................................................................................................................17
Operating Instructions ..........................................................................................................18
Standing Pilot Lighting Instructions ....................................................................................19
Standing Pilot Wiring ...........................................................................................................20
Standing Pilot Troubleshooting ............................................................................................21
Insert Maintenance and Service ...........................................................................................22
Decorative Accessories .........................................................................................................23
Insert Parts View ..................................................................................................................24
Insert Parts List .....................................................................................................................25
How to Order Repair Parts ...................................................................................................26
Service Notes .................................................................................................................. 26-27
23015-6-0408Page 2
IMPORTANT SAFETY INFORMATION
Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.
DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Adequate accessibility clearances for servicing and proper operation should be maintained.
This appliance must not share or be connected to a flue serving a separate solid-fuel burning appliance.
Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies.
The glass front or any part removed for servicing the appliance must be replaced prior to operating the appliance. Work should be done by a qualified service person.
Keep burner and control compartment clean.
Vent cap is hot while fireplace is in operation.
Installation and repair should be done by a QUALIFIED SERVICE PERSON. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding materials, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapor and liquids.
Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this appli ance.
The flow of combustion and ventilation air must not be obstructed in any way.
DO keep the appliance area clear and free from combustible material, gasoline and other flammable vapors and liquids.
DO examine venting system periodically and replace damaged parts.
DO make a periodic visual check of pilot and burners. Clean and replace damaged parts.
CAUTION: The glass used in your fireplace insert is ceramic glass. If the glass is cracked or damaged in any way, it should be replaced only with a complete glass frame assembly from Empire. See parts list on Page 25 for ordering.
DO NOT use this fireplace insert if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.
-
DO NOT put anything around the fireplace insert that will obstruct the flow of ventilation air.
Maintain clearances in accordance with local installation codes and the requirements of the gas supplier.
23015-6-0408 Page 3
Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the appliance.
SAFETY INFORMATION FOR USERS OF LP GAS
Propane (LP-Gas) is a flammable gas which can cause fires and explosions. In its natural state, propane is odorless and colorless. You may not know all the following safety precau tions which can protect both you and your family from an accident. Read them carefully now, then review them point
LP-GAS WARNING ODOR
If a gas leak happens, you should be able to smell the gas because of the odorant put in the LP-Gas.
That’s your signal to go into immediate action!
• Do not operate electric switches, light matches, use your phone. Do not do anything that could ignite the gas.
• Get everyone out of the building, vehicle, trailer, or area. Do that IMMEDIATELY.
• Close all gas tank or cylinder supply valves.
• LP-Gas is heavier than air and may settle in low areas such as basements. When you have reason to suspect a gas leak, keep out of basements and other low areas. Stay out until firefighters declare them to be safe.
NO ODOR DETECTED - ODOR FADE
Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. You must find out if you can smell the odorant in propane. Smoking can decrease your
ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor. Sometimes other odors in the area mask the gas odor. People may not smell the gas odor or their minds are on something else. Thinking about smelling a gas odor can make it easier to smell.
The odorant in LP-Gas is colorless, and it can fade under some circumstances. For example, if there is an underground leak, the
movement of the gas through soil can filter the odorant. Odorants
by point with the members of your household. Someday when there may not be a minute to lose, everyone’s safety will depend on knowing exactly what to do. If, after read
­ing the following information, you feel you still need more information, please contact your gas supplier.
• Use your neighbor’s phone and call a trained LP-Gas service person and the fire department. Even though you may not continue to smell gas, do not turn on the gas again. Do not re-enter the building, vehicle, trailer, or area.
Finally, let the service man and firefighters check for escaped gas. Have them air out the area before you return. Properly trained LP-Gas service people should repair the leak, then check and relight the gas appliance for you.
in LP-Gas also are subject to oxidation. This fading can occur if there is rust inside the storage tank or in iron gas pipes.
The odorant in escaped gas can adsorb or absorb onto or into walls, masonry and other materials and fabrics in a room. That will take some of the odorant out of the gas, reducing its odor intensity.
LP-Gas may stratify in a closed area, and the odor intensity could vary at different levels. Since it is heavier than air, there may be more odor at lower levels. Always be sensitive to the slightest gas odor. If you detect any odor, treat it as a serious leak. Immediately go into action as instructed earlier.
-
SOME POINTS TO REMEMBER
Learn to recognize the odor of LP-Gas. Your local LP-Gas Dealer can give you a “Scratch and Sniff” pamphlet. Use it to find out what the propane odor smells like. If you suspect that your LP-Gas has a weak or abnormal odor, call your LP-Gas Dealer.
• If you are not qualified, do not light pilot lights, perform service, or make adjustments to appliances on the LP-Gas system. If you are qualified, consciously think about the odor of LP-Gas prior to and while lighting pilot lights or performing service or making adjustments.
• Sometimes a basement or a closed-up house has a musty smell that can cover up the LP-Gas odor. Do not try to light pilot lights, perform service, or make adjustments in an area where the conditions are such that you may not detect the odor if there has been a leak of LP-Gas.
• Odor fade, due to oxidation by rust or adsorption on walls of new cylinders and tanks, is possible. Therefore, people should be particularly alert and careful when new tanks or cylinders are placed in service. Odor fade can occur in new tanks, or reinstalled old tanks, if they are filled and allowed to set too long before refilling. Cylinders and tanks which have been
out of service for a time may develop internal rust which will cause odor fade. If such conditions are suspected to exist, a periodic sniff test of the gas is advisable. If you have any
question about the gas odor, call your periodic sniff test of the LP-Gas is a good safety measure under any condition.
• If, at any time, you do not smell the LP-Gas odorant and you think you should, assume you have a leak. Then take the same immediate action recommended above for the occasion when you do detect the odorized LP-Gas.
• If you experience a complete “gas out,” (the container is under no vapor pressure), turn the tank valve off immediately. If the container valve is left on, the container may draw in some air through openings such as pilot light orifices. If this occurs, some new internal rusting could occur. If the valve is left open, then treat the container as a new tank. Always be sure your container is under vapor pressure by turning it off at the container before it goes completely empty or having it refilled before it is completely empty.
LP-Gas dealer. A
23015-6-0408Page 4
INTRODUCTION
Instructions to Installer
1. Installer must leave instruction manual with owner after installation.
2. Installer must have owner fill out and mail warranty card supplied with the fireplace.
3. Installer should show owner how to start and operate the fireplace.
This direct vent gas fireplace heater is designed to operate with all combustion air being siphoned from the outside of the building and all exhaust gases expelled to the outside of the building. The information contained in this manual pertains to all models and gas control systems unless otherwise noted.
Warning: This unit is not for use with solid fuels.
Appliance Certification
This fireplace is design certified in accordance with American National Standard/CSA Standard ANSI Z.21-88/CSA 2.33 and by Underwriters Laboratories as a Direct Vent Gas Fireplace Heater and shall be installed according to these instructions.
Consult your local building code agency, prior to installation, to ensure compliance with local codes-including permits and inspections.
The fireplace insert, when installed, must be electrically grounded in accordance with local codes or, in absence of local codes, with the National Electric Code ANSI/NFPA 70 or Canadian Electric code, CSA C22.1, if an external electrical source is utilized.
These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada.
Qualified Installing Agency
Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term “qualified agency” means any individual, firm, corporation or company which either in person or through a representative is engaged in and is responsible for (a) the installation or replacement of gas piping or (b) the connection, installation, repair or servicing of equipment, who is experienced in such work, familiar with all precautions required and has complied with all the requirements of the authority having jurisdiction.
State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.
The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code ANSI Z223.1/NFPA
54* Natural Gas and Propane Installation Code, or CSA B149.1 in Canada. *Available from the American National Standards Institute, Inc. 11
West 42nd St., New York, N.Y. 10036.
Warning: ANY CHANGE TO THIS FIREPLACE OR ITS CONTROLS CAN BE DANGEROUS. Improper installation or use of the fireplace can cause serious injury or death from fire, burns, explosions, or carbon monoxide poisoning.
Any alteration of the original design, installed other than as shown in these instructions or use with a type of gas not shown on the rating plate is the responsibility of the person and company making the change. Important
All correspondence should refer to complete Model Number, Serial Number and type of gas.
High Altitude
When installing this unit at an elevation above 2000 feet (in the United States) it may be necessary to decrease the input rating by changing the existing burner orifice to a smaller size. Generally, input should be reduced 4 percent for each 1000 feet above sea level. However, if the heating value of the gas has been reduced, this general rule may not apply. Check with local gas utility for proper orifice size identification.
Canadian High Altitude
Altitude: 0-4500 feet (0-1370 m)
When installing this unit at an elevation above 4500 feet (in Canada), check with local authorities.
Consult your local gas utility for assistance in determining the proper orifice for location.
Preparation
This direct vent gas fireplace insert and its components are tested and safe when installed in accordance with this Installation Manual. Report to your dealer any parts damaged in shipment, specifically check glass condition. Do not install unit with damaged, incomplete, or substitute parts. Read all instructions before starting installation and follow these instructions carefully during installation to insure maximum benefit and safety. Failure to follow them will void your warranty and may present a fire hazard.
The warranty will be voided by, and the warranter disclaims any responsibility for the following actions:
• Installation of any damaged fireplace insert or vent system component.
• Modification of the fireplace insert or direct vent system.
• Installation other than as instructed by Empire Comfort Systems, Inc.
• Improper positioning of the logs or glass door assembly.
• Installation and/or use of any component part not manufactured or approved by manufacturer.
23015-6-0408 Page 5
SPECIFICATIONS
DV25IN33L MODELS LP Nat
Input Btu/hr Maximum 25,000 25,000
Btu/hr Minimum 17,000 17,000
KWH (Maximum) 7.30 7.30
(Minimum) 5.00 5.00
Orifice #53 (0.0596) #42 (0.0935)
Air Shutter Opening Full Open 1/8”
DV33IN33L MODELS
Input Btu/hr Maximum 33,000 33,000
Btu/hr Minimum 25,000 25,000
KWH (Maximum) 9.57 9.57
(Minimum) 7.30 6.67
Orifice
Air Shutter Opening Full Open 3/16”
DV35IN33L MODELS
Input Btu/hr Maximum 35,000 35,000
Minimum 27,000 25,000
KWH (Maximum) 10.15 10.15
(Minimum) 7.83 7.30
Orifice #50 (0.070) #33 (0.113)
Air Shutter Opening Full Open 3/16”
LP Nat
#51 (0.067) #34 (0.111)
LP Nat
Remote Control
Accessories
FRBC Millivolt Battery Remote ON/OFF
FRBTC Millivolt Battery Remote T-Stat
TMV Millivolt WIRELESS Wall Thermostat
TRW Millivolt Reed Switch Wall Thermostat
Surround Kits Description
S256BL 6” Wide, black for use on DV25IN models
S336BL 6” Wide, black for use on DV33IN models
S356BL 6” Wide, black for use on DV35IN models
SC256BL 6” Wide, black for use on DV25IN models
SC336BL 6” Wide, black for use on DV33IN models
SC356BL 6” Wide, black for use on DV35IN models
Description
Contemporary
Traditional Cast Iron
Venting Kits Description Contents
DVKI Vertical Vent Kit - 17 1/2’ One piece of 35’ FlexVent (split for 17 1/2’ vent run), Round Cap, Flashing,
connectors, and clamps. Recommended when installing to an existing round fireplace chimney pipe.
DVVK3FV Vertical Vent Kit - 25’ Two pieces of 25’ FlexVent, Rectangle Cap, Flashing, connectors, and clamps
Recommended when installing to a square or rectangular clay flue.
DVK35 Vent Extension Kit 35’ flex vent extension section with 2 connectors and 4 clamps
Note: When installing vent caps, special locally made flashings may be required to properly seal the vent system to the existing chimney termination.
23015-6-0408Page 6
FIREPLACE INSERT DIMENSIONS
A
D
C
B
When planning a fireplace insert installation, it’s necessary to determine:
The vent system configuration to be used.
Gas supply piping.
Whether optional accessories - devices such as a wall switch
or remote control - are desired.
Electrical supply requirements for blower.
Proper opening size of fireplace required for installation of
the fireplace insert.
DV FIREPLACE INSERT DIMENSIONS
MODEL A B C D E F G H I J K L M N
DV25IN 19 3/4” 28 14 1/2” 11 1/8” 25 1/4” 12 3/4” 17” 18 5/16” 27” 6 3/4” 9” 20” 25 5/8” 40”
DV33IN 22 3/4” 31 16 14 1/8” 28 1/4” 14 1/4” 18 3/4” 21 5/16” 30” 8 1/4” 10 1/2” 21 1/2” 28 5/8” 43”
DV35IN 24 3/4” 34 16 16 1/8” 31 1/4” 14 1/4” 21 3/4” 23 5/16” 33” 8 1/4” 10 1/2” 23” 30 5/8” 46”
Figure 1
Fireplace Opening Dimensional Information/Sizing
MINIMUM FIREPLACE OPENING DIMENSIONS
MODEL
NO.
DV25IN 18 3/8” 27 1/2” 12 3/4” 17 1/4”
DV33IN 21 3/8” 30 1/2” 14 1/4” 19”
DV35IN 23 3/8” 33 1/2” 14 1/4” 22”
HEIGHT A*FRONT WIDTH
B
*Note: If the fireplace lintel is wider than 8” (203mm), the height of the fireplace opening must be increased a few inches to allow for a gradual offset in the exhaust and/or intake vent pipes.
DEPTH
C
REAR WIDTH
D
23015-6-0408 Page 7
Figure 2
MANTLE AND TRIM CLEARANCES
COMBUSTIBLE MANTEL/TRIM AREA
12”
10”
1 3/4”
23”
11
8”
MINIMUM CLEARANCE TO PERPENDICULAR
COMBUSTIBLE SIDE-WALL
(FROM EDGE
OF DOOR FRAME)
Figure 3
Figure 4
Combustible Material
No greeting cards, stockings or ornamentation of any type should be placed on or attached to the fireplace. The flow of heat can ignite combustibles.
23015-6-0408Page 8
GAS SUPPLY
GAS FLEX LINE WITH
SHUTOFF VALVE
(PROVIDED)
FRONT OF
INSERT
RIGHT SIDE OF INSERT
The gas pipeline can be brought in through the right or left side of the appliance. The insert has a Flexline with shutoff valve located on the right side when facing the unit. See Figures 5 and 6. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code.
Recommended Gas Pipe Diameter
Pipe Length Schedule 40 Pipe
Inside Diameter
Nat. L.P. Nat. L.P.
0-10ft
0-3m
11-40ft
4-12m
41-100ft
13-30m
101-150ft
31-46m
1/2"
12.7mm
1/2"
12.7mm
1/2"
12.7mm
3/4" 19mm
3/8"
9.5mm
1/2"
12.7mm
1/2"
12.7mm
1/2"
12.7mm
Tubing, Type L Outside Diameter
1/2"
12.7mm
5/8"
15.9mm
3/4" 19mm
7/8"
22.2mm
3/8"
9.5mm
1/2"
12.7mm
1/2"
12.7mm
3/4"
1.9 mm
Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.
The use of the following gas connectors is recommended:
— ANS Z21.24 Appliance Connectors of Corrugated Metal Tubing
and Fittings.
— ANS Z21.45 Assembled Flexible Appliance Connectors of
Other Than All-Metal Construction The above connectors may be used if acceptable by the authority having jurisdiction. The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.
Figure 5
Installing the Main Gas Cock
Each appliance should have its own manual gas cock. A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not ad­equate, contact your local authorized installer for installation or relocation. Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.
Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!
NOTE: The millivolt gas controls are equipped with a captured
screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.
When using copper or flex connector use only approved fittings. The appliance and it’s individual shut off valve must be disconnected from supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5kPa). The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa). Attention! If one of the procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the fireplace gas valve, it will result in a hazardous condition.
Checking Manifold Pressures
Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of
14.0" w.c. (3.484kPa). Propane gas models will have a manifold pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 10.8" w.c. (2.68kPa) for the purpose of input adjustment to a maximum of
14.0" w.c. (3.484kPa).
Gas Supply Pressure (inches w.c.)
Minimum Normal Maximum
Natural Gas 4.5" 7.0" 14.0"
LP (Propane)
Natural Gas 3.5"
LP (Propane)
23015-6-0408 Page 9
10.8" 11.0" 14.0"
Manifold Pressure (inches w.c.)
Normal (HI)
10.0"
Figure 6
VENTING AND INSTALLATION
1. Before beginning, remove glass door and log package from
unit. Also check to make sure there is no hidden damage to
the unit. Take a minute and plan out the gas, venting and elec-
trical route. It is best to start with the gas line first, followed
by the chimney liner and electrical supply requirements.
2. Minimum fireplace opening requirements are shown in
Figure 2 of this installation manual. The firebrick (refrac-
tory), glass doors, screen rails, screen mesh and log grates
can be removed from a factory built fireplace in order to gain
minimum gas insert opening requirements prior to installing
the gas fireplace insert.
3. This insert requires no hearth extensions. Combustible ma
terial on the floor may be installed up to the insert. Do not
obstruct the lower louver of the insert. The original fireplace
cannot be returned to solid fuel in this condition.
4. The metal floor of the solid fuel firebox may be removed to
facilitate the installation of the insert. CLEARANCE TO
COMBUSTIBLE MATERIAL UNDER THE INSERT IS
1/4”. YOU MUST USE THE LEVELING LEGS TO RAISE
THE INSERT A MINIMUM OF 1/4” IF THE INSERT IS
TO SIT ON COMBUSTIBLE MATERIAL. The side walls
and top structure of the firebox may not be altered with the
exception of removable baffles and dampers. Smoke shields,
shelves and baffles may be removed if attached with me
chanical fasteners. The original fireplace cannot be returned
to solid fuel in this condition.
5. Combustible facing material may be installed over the
original combustible facing material on the solid fuel fire
place. The original specified clearances of a factory-built
fireplace must be maintained, with the exception of the
hearth. Clearances on a masonry fireplace must be main-
tained at 12” from the opening for combustible projections
over 1 1/2”. Clearances for combustible projections under
1 1/2” must be maintained at 6” from the opening per
NFPA211. Plan the surround size accordingly. A surround
must be used with the insert. UNDER NO CIRCUMSTANCE
CAN COMBUSTIBLE MATERIAL BE PLACED BEHIND
THE SURROUND!
6. The insert surround is tested and approved with this gas insert
and may cover existing air circulation vents or grills on the
solid fuel fireplace it is installed into. If the surround does
not cover the entire ventilation grill surface, the exposed grill
area should be left open.
NOTE: Surround panel kits have been tested and approved to cover existing air circulation vents or grills.
NOTE: Cutting of sheet metal parts of a fireplace in order to install the fireplace insert is prohibited.
WARNING: Only the surround as supplied may be used to cover integral grills on the solid fuel-burning fireplace. No other components such as shrouds, sheet metal plates, etc. may be used to seal off vents.
7. To assure top performance, safety and efficiency, inserts must be installed with an approved flue liner as per CAN/CGA B-149 or National Fuel Code ANSI Z223 and these instruc­tions.
Note: The following statement is also provided on a separate label plate in the instruction packet. Prior to installation of the fireplace insert, the installer must mechanically secure this warning plate to the inside of the fireplace for future reference as required.
WARNING: The solid fuel fireplace has been converted for use with gas only and cannot be used for burning wood
-
-
-
or solid fuels unless all original parts have been replaced and the fireplace has been reapproved by the authority having jurisdiction.
8. The solid fuel fireplaces’ flue damper must be fully locked in the open position or removed for installation of the gas fireplace insert.
9. The fireplace and fireplace chimney must be cleaned and in good working order and constructed of noncombustible ma­terials.
10. Make sure that all chimney cleanouts fit properly so air can not leak into the chimney.
11. Install the insert without the surround panels attached and make all gas, venting, and electrical connections.
If the factory built fireplace does not have gas access holes provided, an access hole of 1 1/2” diameter (37.5mm) or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship like manner. This access hole must be plugged with a non-combustible insu lation after the gas supply line has been installed.
12. To complete the installation, install surround panel assembly. Please refer to instructions included with the surround panel kit.
Ensure there are no obstructions to side air passages of decorative trim once installed on insert.
INSTALLING THE VENT SYSTEM
Vent System Installation Precautions
Before starting installation of vent kits, the installer should read these instructions and the Vent Kit Instructions to ensure that a proper vent installation is completed. Consult your local Building Codes before beginning the Installation.
WARNING: THIS GAS INSERT AND VENT ASSEMBLY MUST BE VENTED DIRECTLY TO THE OUTSIDE AND MUST NEVER BE ATTACHED TO A CHIMNEY SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. EACH GAS APPLIANCE MUST USE A SEPARATE VENT SYSTEM. COMMON VENT SYSTEMS ARE PROHIBITED.
-
-
23015-6-0408Page 10
VENTING AND INSTALLATION
Vent System Approvals Figure 8 shows the vent termination caps and systems approved
for use with these models. Approved vent system terminations are labeled for identification. 3-inch diameter listed flexible aluminum or stainless steel gas vent is used for both the incoming combustion air and exhaust vent pipes. NO OTHER VENTING SYSTEMS OR COMPONENTS MAY BE USED. Detailed installation instructions are included with each vent termination kit and should be used in conjunction with this manual.
Horizontal Venting
The vent system on this model CANNOT be terminated horizontally.
Vertical Venting
The inlet and exhaust vent pipes MUST be connected to the proper collars on the unit will not operate. The intake vent collar is identified by a stamped “I” on the top collar sliding vent plate assembly.
WARNING: MAJOR U.S. BUILDING CODES SPECIFY MINIMUM CHIMNEY AND/OR VENT HEIGHT ABOVE THE ROOF TOP. THESE MINIMUM HEIGHTS ARE NECESSARY IN THE INTEREST OF SAFETY. SEE FIGURES 8 THROUGH 10 FOR MINIMUM HEIGHTS, PROVIDED THE TERMINATION CAP IS AT LEAST 2-FEET FROM A VERTICAL WALL AND 2-FEET BELOW A HORIZONTAL OVERHANG.
Note: This also pertains to vertical vent systems installed on the
outside of the building.
WARNING: THE EXHAUST PIPE MUST ONLY BE CONNECTED TO THE EXHAUST STARTING COLLAR OF THE UNIT AND TO THE EXHAUST COLLAR OF THE TERMINATION CAP.
THE INLET AIR PIPE MUST ONLY BE CONNECTED TO THE INLET AIR STARTING COLLAR OF THE UNIT AND TO THE INLET AIR COLLAR OF THE TERMINATION CAP. BOTH THE INLET VENT AND THE FLUE VENT MUST BE CONNECTED FROM THE INSERT TO THE VENT TERMINATION CAP.
NOTE: The minimum vertical vent rise is 10 feet and the
maximum vertical vent rise is 35 feet. These dimensions are measured from the starting collars of the unit to the end of the last section of vent pipe. See Figure 8.
NOTE: The damper of the masonry chimney may need to be removed to allow installation of the flexible-vent pipe.
When installing into a zero clearance, factory built wood-burning fireplaces, the use of the DVKI Round Vertical Termination Kit should allow you to mount the vent adaptor and cap to the exposed round chimney pipe easily.
AND to the termination cap or the unit
Connecting the Vent Pipe
Caution: Sharp edges. Always use gloves when installing.
Install the 3-inch flexible vent pipes down through the chimney.
Attach the pipe-to-cap adaptor to the termination cap and the top of the flexible vent pipe, then install the cap to the top of the chimney.
Remove the vent slide plate assembly from the top of the insert. See Figure 7. Trim off excess venting then attach and secure the bottom ends of the flex pipes to the starting collars with the adjustable band clamps provided. Slide the gas insert into place, and position any excess flex vent pipe back up into the chimney. Begin installation of the insert into the fireplace opening. Align the vent slide plate assembly with the guides located on top of the insert. Work the insert inch by inch into the fireplace cavity as you pull forward on the vent slide plate assembly. Do not use excessive force on the vent slide plate. Once the vent slide plate is close to seating, install the vent bolt through the center hole of the insert top flange, and into the vent slide plate nut. Using a wrench or socket, tighten the bolt until the vent slide plate is seated forward completely.
Positioning, Leveling, and Securing Insert
1. Place the insert into position.
Note: The front flanges of the insert (without surround panels) should be set at approximately 1”(inch) in front of the face of the fireplace.
2. Level the insert from side to side and front to back.
3. If necessary, use the leveling bolts included in the instruction pack. Screw the legs into the nuts installed in the bottom of the insert. Turn legs in until insert is level.
CAUTION: TO AVOID DOWNDRAFTS AND/OR COLD AIR PROBLEMS, IT IS RECOMMENDED TO SEAL OFF THE AREA BETWEEN THE TERMINATION CAP AND THE TOP OF THE SOLID-FUEL CHIMNEY OPENING INTO WHICH THE VENT CAP HAS BEEN INSTALLED.
23015-6-0408 Page 11
Figure 7
RECTANGULAR
TERMINATION CAP
(DVVK3FV KIT)
VENT CLAMPS
INTAKE VENT
FLUE EXHAUST VENT
OPTIONAL ON/OFF SWITCH LOCA
TION
10’ MINIMUM 35’ MAXIMUM
VENT CLAMPS
NOTE: LONG EXTENSION TUBE FOR INLET VENT CONNECTION.
RETAINER SCREWS MAY BE INSTALLED THROUGH THE VENT CLAMPS TO ENSURE POSITIVE SECUREMENT OF VENTING.
SCREWS ADDED THROUGH VENT CLAMPS TO RETAIN VENTING TO COLLARS RECOMMENDED.
USE HIGH TEM
P SEALANT ON VENT CONNECTIONS
USE HIGH TEMP SEALANT ON VENT CONNECTIONS
ROUND
TERMINATION CAP
(DVKI KIT)
ROUND CO-LINEAR TO
CO-AXIAL ADAPTOR
BLOWER ACCESS COVER PLA
TE
BLOWE
R
POWER CORD
OPTIONAL LOW VOLTAGE WIRES
OPTIONAL ON/OFF SWITCH LOCATION
VENTING AND INSTALLATION
Figure 8
23015-6-0408Page 12
VERTICAL TERMINATION
MIN.
12"
MIN.
24"
24"
MIN.
C
L
Determining Minimum Vent Height Above the Roof.
WARNING: Major U.S. building codes specify minimum chimney and/or vent height above the roof top. These minimum heights are necessary in the interest of safety. These specifica tions are summarized in Figure 9.
ROOF PITCH H (Min.)
Flat to 6/12 12" (305 mm)
6/12 to 7/12 15" (381 mm)
Over 7/12 to 8/12 18" (457 mm)
Over 8/12 to 16/12 24" (610 mm)
Over 16/12 to 21/12 36" (914 mm)
Figure 9
Note that for steep roof pitches, the vent height must be increased. In high wind conditions, nearby trees, adjoining roof lines, steep pitched roofs, and other similar factors can result in poor draft, or down-drafting. In these cases, increasing the vent height may solve this problem.
Vertical Through the Roof Applications
The Gas Fireplace Insert has been approved for: a) Vertical installations up to 35 feet in height (top of insert to
-
cap).
b) Two sets of 45 degree elbow offsets (bends in flexvent) within
the vertical installation. From 0 to a maximum of 8 ft. of vent pipe can be used between elbows.
c) Wall straps must be used to support offset pipe every 4'.
This application will require that you first determine the roof pitch and use the appropriate venting components.
General Maintenance
Conduct an inspection of the venting system semi-annually. Recommended areas to inspect are as follows:
1. Check areas of the venting system which are exposed to the elements for corrosion. These will appear as rust spots or streaks and, in extreme cases, holes. These components should immediately be replaced.
2. Remove the cap and shine a flashlight down the vent. Remove any bird nests or other foreign material.
3. Check for evidence of excessive condensate, such as water droplets forming in the flex venting and subsequently dripping out at joints or seams. Condensate can cause corrosion of caps, pipe and fittings. It may be caused by having excessive lateral runs, or having exterior portions of the system exposed to cold weather.
4. Inspect joints to verify that no pipe sections or fittings have been disturbed and, consequently, loosened. Also, check mechanical supports, such as wall straps or plumbers’ tape for rigidity.
Figure 10
When terminating the vent cap near an exterior wall or overhang, maintain minimum clearances as shown in Figure 10.
23015-6-0408 Page 13
ALTERNATE ON/OFF SWITCH INSTALLATION
WIRING FROM
MILLIVOL
T GAS
VALV
E
ON/OFF
SWITCH
ASSEMBLY
Right Side Installation
Left Side Installation
ON/OFF SWITCH
ASSEMBL
Y
WIRING THE FIREPLACE
Note: Electrical wiring must be installed by a licensed electrician.
CAUTION: DISCONNECT REMOTE CONTROLS IF YOU ARE AB­SENT FOR EXTENDED TIME PERIODS. THIS WILL PREVENT ACCIDENTAL FIREPLACE OPERATION.
Installation of Alternate Surround Panel ON/OFF Switch
An ON/OFF switch and wire assembly are provided. They are included in the instruction packet. Do not cut wire or insulation on metal edges.
Note: Refer to surround panel installation section on page 15 for ad­ditional information on attachment.
Contemporary Surrounds
1. Find the coiled low voltage wire assembly and ON/OFF switch lo cated in the instruction packet.
2. Attach the flag terminal ends to the “TH/TP” and “TH” terminals on the front terminal block of the gas valve. See Figure 13.
3. Run the low voltage alternate switch wires up the back of the right or left surround panel. Then secure the wires with wire clips pro vided. See Figure 11.
-
Figure 12
Note: For right side leg installation, reverse switch position in
bracket.
3. Run the low voltage alternate switch wires up the back of the right
-
or left cast surround leg. Then secure them with the wire clips pro vided.
4. Install the switch bracket with screws as shown in Figure 12 to the back of the cast surround leg.
5. Install ON/OFF switch, and connect low-voltage wires from gas valve.
6. Attach cast surround panel assembly to the insert. Place the cast surround assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides. Lift the cast sur round assembly slightly until the bottom return flange (top panel) is positioned over the top flange on the insert. This secures the cast surround assembly to the insert without screws.
-
-
Figure 11
Insert ON/OFF switch into side panel then attach wire assembly
from valve terminals.
4. Remove the switch knockout on the side surround panel, then install the ON/OFF switch.
5. Connect the low voltage wires from the gas valve to the ON/OFF switch.
6. Attach the surround panel assembly to the insert. Place the surround panel assembly against the face of the insert and align the lower retaining tabs with the notches on the insert sides. Lift the surround panel assembly slightly until the bottom return flange (top panel) is positioned over the top flange on the insert. This secures the sur­round panel assembly to the insert without screws.
Traditional Cast Iron Surrounds
1. Find the coiled low voltage wire assembly and ON/OFF switch lo cated in the instruction packet.
2. Attach the flag terminal ends to the “TH/TP” and “TH” terminals on the front terminal block of the gas valve. See Figure 13.
Figure 13
-
23015-6-0408Page 14
SURROUND PANEL INSTALLATION
NOTE: INSTALL SURROUND PANELS
SO THAT THE TOP PANEL RETURN FLANGE SLIDE’
S OVER THE TOP FLANGE ON THE INSER
T
1” Ref.
SURROUND PANEL ASSEMBLY
ENGAGE SIDE PANEL HOOKS W
ITH THE
NOTCHES PROVIDED O
N
THE SIDE FLANGE
S
INSTALLING THE TRIM SURROUNDS
Combustible materials MUST NEVER overlap onto the front face.
WARNING: WHEN FINISHING THE FIREPLACE INSERT, NEVER OBSTRUCT OR MODIFY THE AIR INLET/OUTLET LOUVERS ON THE FIREPLACE IN SERT IN ANY MANNER.
-
Figure 15
Figure 14
23015-6-0408 Page 15
BLOWER ACCESSORY INFORMATION
The appliance, when installed must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.
U.S. Installations, follow local codes and the National Electrical Code, ANSI/NFPA No. 70.
Should this blower require servicing, the power supply must be disconnected. For rewiring of any replacement components, re­fer to Figures 16 and 17 and the parts list on page 25.
BLOWER ACCESSORY Operation
The fireplace insert is equipped with a factory installed blower accessory that includes a fan control switch, plus a rheostat (speed control). The speed control knob is located behind the lower louver at the right side of the insert. From a cold start, the temperature activated fan control switch will normally take 5-10 minutes to heat up and energize the blower. Once the blower is energized, adjust the blower speed control as desired, then replace the lower louver. When the insert is shut off, it may take 30-40 minutes for the heated unit to dissipate (cool down) enough for the blower to shut off automatically. Note: The blower shut off times will vary on blower speed and BTU input level setting control by adjustment of the HI/LO knob located on the gas valve.
Blower removal instructions
Servicing or removal of the blower system must be performed by a qualified service person. If the blower assembly (Item 45, page 24) must be replaced, the following steps are recommended for removal:
Figure 16
1. Turn off gas and disconnect the electrical supply.
2. Remove the glass door assembly.
3. Remove the log set.
4. Remove the front surround panel assembly by lifting upward and outward to detach.
5. Remove the 5/16” x 2-1/2” center bolt that retains the Vent Slide plate assembly.
6. Remove the insert from the fireplace cavity by pulling forward on the insert, and at the same time, sliding the vent plate rearward until disengaged.
7. As the insert is moved outward, the gas line may need to be disconnected at the insert shut off valve. If so, make sure the main gas line is shut off that supplies gas to the insert.
8. Once the insert is pulled out, the blower assembly can be removed by locating the (6) screws on the lower back of the insert that retains the blower base plate.
9. When the screws are removed, gently pull the blower assembly outward.
10. Disconnect the two ¼” wire terminals from the motor.
11. Remove the (4) screws that retain the blower assembly to the base plate, and set blower aside.
12. Install the replacement blower, and re-install the insert by reversing above steps.
Figure 17
23015-6-0408Page 16
LOG PLACEMENT
BACK
LOG
LEFT TWIG
RIGHT
TWIG
RIGH
T
CENTER
LOG
RIGHT FRONT
LOG
LEFT FRONT
LOG
LEFT
CENTER
LOG
Before you begin: This fireplace insert is supplied with a set of seven ce ramic fiber logs. Do not handle these logs with your bare hands. Always wear gloves to prevent skin irritation from ceramic fibers. After handling logs, wash your hands gently with soap and water to remove any traces of fiber.
The positioning of logs is critical to safe and clean operation of this fireplace. Sooting and other problems may result if the logs are not properly and firmly positioned in the fireplace. Refer to Figure 18 and Figure 19 and corresponding WARNING when completing following log placement steps.
1. Remove top louver, grasp louver, lift and pull forward.
2. Lower bottom louver, lift and hinge forward.
3. Release two glass frame spring clamps at bottom of the glass door assembly.
4. Swing the bottom of the glass door outward approximately 10-15 degrees, then grasping the edges, gently lift upward to remove the door assembly, and set aside.
5. Remove the foam packaging that contains the log set from inside the firebox.
6. Carefully unpack the logs and twigs. Spread them out for easy identification.
7. Begin with the front left and front right logs. Place these so that they are centered left to right on the front log support ledge. The flat bottoms will rest on top of the front log support ledge, and they must be position all the way forward and touching the back of the grate tangs. Important: The front right log has a small knot as shown in Figure 18.
8. Next install the large rear log. It will be centered left to right and placed all the way to the back of the firebox, on top of the rear log support. Note: DV25IN models incorporate two small tabs in the rear log support that keep the back log positioned correctly. DV33IN models have one small tab in the rear log support to ensure the back log is in the correct position. The DV35IN models will have two tabs bent forward in the rear log support to ensure proper left to right positioning of the log, plus one small tab near the center that keeps the back log from shifting forward.
9. Locate the center left log. It will have two locator pin holes on the bottom flat surface. Align the two holes with the two left pins on the burner assembly. Make sure this log is not raised up off of the burner. The flat bottom surface must be completely resting flat on the top of the burner surface.
10. Install the center right log. It will also have two locator pin holes on the bottom flat surface. Align these two holes with the two right pins on the burner assembly. Make sure this log is not raised up off of the burner. The flat bottom surface must be completely resting flat on the top of the burner surface.
11. Add the right twig by placing the locator pin hole on the bottom of the twig with the pin on top of the center right log. The tip of the right twig will rest on top of the rear log near the right end.
12. Add the left twig by placing the locator pin hole on the bottom of the twig with the pin on top of the center left log. The long branch of the left twig will rest in a small groove on top of the rear log. This groove is near the left end of the rear log.
Note: Decorative Rock is not included with the Fireplace Insert, however it may be purchased separately and placed only on the firebox floor. Do Not place decorative rock or rock wool on the logs or burner assembly.
-
13. Replace the glass door assembly onto the fireplace insert.
14. Secure the glass door with the two spring clamps located under the firebox.
15. Re-install the upper and lower louver assemblies by aligning the end tabs with the slots provided in the outer face flanges of the insert.
Figure 18
Warning: Failure to position the parts in accordance with this dia gram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.
Figure 19
Note: Center the front two logs on the front log support ledge. Then make
sure they are positioned all the way forward and touching the back edges of the grate tang uprights. The bottom of the two front logs are flat and must sit on top of the front log support ledge.
-
23015-6-0408 Page 17
OPERATING INSTRUCTIONS
750 Millivolt System
The standing pilot (750 millivolt system) is a continuous burning pilot. The pilot remains ON even when the main burner is OFF.
When you ignite the pilot, the thermopile produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operate an additional one (1) to two (2) minutes before you turn the gas control knob from the PILOT position to the ON position. This time period allows the millivolts (electrical current) to build-up to a sufficient level allowing the gas control to operate properly.
1. Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in control compartment behind the door assembly.
CAUTION: During the initial purging and subsequent lightings, never allow the gas valve control knob to remain depressed in the “pilot” position without pushing the piezo ignitor button at least once every second.
2. During the operating season, leave the control valve knob in the “ON” position. This will allow the pilot flame to remain lit. Turn the burner flame on or off with the fireplace REMOTE/OFF/ON switch, wall switch or remote controls.
NOTE: The gas control valve allows you to increase or decrease the height of the main burner flame. The control valve has a pressure regulator with a knob as shown in Figure 20. Rotate the knob clockwise to “HI” to increase the flame height and counterclockwise to “LO” to decrease the flame height.
3. When the operating season is over, turn the switch to “OFF” and the control valve to “OFF”. The system, including the pilot light, will be shut down.
REMOTE/OFF/ON
Initial Lighting
Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amount of air will be in the lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and operate satisfactorily.
Subsequent lightings of the appliance will not require such purging if the gas valve is not turned to “OFF.”
Pilot Flame (Figure 21)
The thermopile/thermocouple (standing pilot) tips should be covered with flame.
Figure 21
Figure 20
The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the fireplace.
23015-6-0408Page 18
STANDING PILOT LIGHTING INSTRUCTIONS
FOR YOUR SAFETY READ BEFORE LIGHTING
WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. Before lighting smell all around the appliance area for gas.
Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.
What To Do If You Smell Gas
• Do not try to light any appliance.
• Do not touch any electrical switch;
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
LIGHTING INSTRUCTIONS
1. Stop! Read the safety information above.
2. Set REMOTE/OFF/ON switch to OFF.
3. Turn off all electric power to the appliance (if applicable).
4. Lower bottom louver assembly.
5. Push in gas control knob slightly and turn clockwise to "OFF."
Note: Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly. Do not force.
6. Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you then smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.
7. Find pilot - Follow metal tube from gas control. The pilot is behind the burner on the right side.
8. Turn gas control knob counterclockwise
to "PILOT."
• If you cannot reach your gas supplier, call the fire depart ment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by hand, don't try to repair it; call a qualified service technician. Force or attempted repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.
9. Push in control knob all the way and hold in. Repeatedly push the piezo ignitor button until the pilot is lit. Continue to hold the control knob in the for about one (1) minute after the pilot is lit. Release knob, and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 9.
If the control knob does not pop up when released, STOP and IMMEDIATELY call a qualified service technician or gas supplier.
If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.
10. Turn gas control knob counterclockwise to "ON."
11. Close bottom louver assembly.
12. Turn on all electric power to the appliance (if applicable).
13. Set REMOTE/OFF/ON switch to desired setting.
-
TO TURN OFF GAS TO FIREPLACE
1. Set REMOTE/OFF/ON switch to OFF.
2. Turn off all electric power to the appliance if service is to be performed (if applicable).
3. Lower bottom louver assembly.
23015-6-0408 Page 19
4. Push in gas control knob slightly and turn clockwise to "OFF." Do not force.
5. Close bottom louver assembly.
STANDING PILOT WIRING
For Standing Pilot Ignition Wiring
Appliance Requirements
WARNING: DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DE STROYED.
STANDING PILOT WIRING DIAGRAM
Optional Wall Switch
Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace valve pigtails.
-
WARNING: DO NOT CONNECT THE 110-120 VAC TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC TION WHEN SERVICING CONTROL. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
-
23015-6-0408Page 20
STANDING PILOT TROUBLESHOOTING
With proper installation and maintenance, your new Direct Vent Gas Fireplace will provide years of trouble-free service. If you do experience a problem, refer to the Trouble Shooting Guide below. This guide will assist a qualified service person in the diagnosis of problems and the corrective action to be taken.
1. Spark ignitor will not light pilot after repeated triggering of piezo ignitor button.
a. Defective ignitor (no spark electrode) —Check for spark at electrode and pilot; if no spark and
electrode wire is properly connected, replace ignitor. b. No gas or low gas pressure. —Check remote shut off valves from fireplace. Usually
there is a valve near the main. There can be more than one
(1) valve between the fireplace and main. —Low pressure can be caused by a variety of situations
such as a bent line, too narrow diameter of pipe, or low line
pressure. Consult with plumber or gas supplier. c. No LP in tank. —Check LP (propane) tank. Refill tank.
2. Pilot will not stay lit after carefully following lighting instructions.
a. Defective thermocouple. —Check that pilot flame impinges on thermocouple. Clean
and/or adjust pilot for maximum flame impingement.
—Ensure the thermocouple connection at the gas valve is
fully inserted and tight (hand tight plus 1/4 turn). Faulty thermocouple if reading is below specified minimum of 15 millivolts.
—Disconnect the thermocouple from the valve, place one
millivolt meter lead wire on the end of the thermocouple and the other millivolt meter lead wire on the thermocouple copper wire. Start the pilot and hold the valve knob in. If the millivolt reading is less than 15 millivolt, replace the
thermocouple. b. Defective valve. —If thermocouple is producing more than 15 millivolts,
replace faulty valve.
3. Pilot burning, no gas to burner, valve knob “ON”, REMOTE/ OFF/ON switch “ON.”
a. REMOTE/OFF/ON switch, wall switch, remote control or
wires defective.
—Check REMOTE/OFF/ON switch and wires for proper
connections. Place jumper wires across terminal at switch. If burner comes on, replace defective switch. If OK, place jumper wires across switch wires at gas valve-if burner
comes on, wires are faulty or connections are bad. b. Thermopile may not be generating sufficient millivolts. —If the pilot flame is not close enough physically to the
thermopile, adjust the pilot flame. —Be sure the wire connections from the thermopile at the
gas valve terminals are tight and the thermopile is fully
inserted into the pilot bracket. —Check the thermopile with a millivolt meter. Take the
reading at TH-TP & TP terminals of the gas valve. The meter
should read 350 millivolts minimum, while holding the valve
knob depressed in the
PILOT position, with the pilot lit, and
the REMOTE/OFF/ON switch in the OFF position. Replace the faulty thermopile if the reading is below the specified minimum.
—With the pilot in the ON position, disconnect the thermopile
leads from the valve. Take a reading at the thermopile leads. The reading should be 350 millivolts minimum. Replace the
thermopile if the reading is below the minimum. c. Defective valve. —Turn valve knob to ON. Place REMOTE/OFF/ON switch
to ON. Check with millivolt meter at thermopile terminals.
Millivolt meter should read greater than 200 millivolts. If the
reading is okay and the main burner does not ignite, replace
the gas valve. d. Plugged main burner orifice. —Check main burner orifice for blockage and remove.
4. Frequent pilot outage problem.
a. Pilot flame may be too high or too low, or blowing (high),
causing pilot safety to drop out. —Clean and adjust flame for maximum flame impingement on
the thermocouple. Follow lighting instructions carefully.
5. The pilot and main burner extinguish while in operation.
a. No LP (Propane) in tank.
Check LP (Propane) tank. Refill fuel tank. b. Inner vent pipe leaking exhaust gases back into system. —Check for leaks. c. Glass too loose, gasket leaks in corners after usage. —Be certain glass assembly is installed correctly. d. Horizontal vent improperly pitched. —The horizontal vent cap should slope down only enough
to prevent any water from entering the unit. The maximum
downwards slope is 1/4 inch. e. Bad thermopile or thermocouple. —Replace if necessary. f. Improper vent cap installation. —Check for proper installation and freedom from debris or
blockage.
6. Glass soots, and/or soot deposits collected on logs.
a. Flame impingement on logs incorrect. —Check and adjust log position. See Page 17. Contact
Empire Comfort Systems, Inc. b. Debris around throat of main burner. —Inspect the opening at the base of the main burner. It is
imperative that NO material be placed in this opening.
7. Flame burns blue and lifts off main burner.
a. Insufficient oxygen being supplied. —Check to make sure vent cap is installed properly and free
of debris. Make sure that vent system joints are tight and
have no leaks. —Check to make sure that no material has been placed at
the main burner base.
23015-6-0408 Page 21
INSERT MAINTENANCE AND SERVICE
Although the frequency of servicing and maintenance will depend on use and the type of installation, you should have a qualified service technician perform an appliance checkup at the beginning of each heating season. Specific guidelines regarding each appliance maintenance task are listed below.
IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR APPLIANCE.
Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician. Task: Brush or vacuum the control compartment, fireplace logs
and burner areas surrounding the logs.
Checking Flame Patterns, Flame Height Frequency: Periodically. By: Qualified service technician/Home owner. Task: Make a visual check of your fireplace’s flame patterns.
Make sure the flames are steady - not lifting or floating. The thermopile/thermocouple (standing pilot) tips should be covered with flame. See Figure 21.
Checking Vent System Frequency: Before initial use and at least annually thereafter,
more frequently if possible.
By: Qualified service technician/Home owner. Task: Inspect the external vent cap on a regular basis to ensure
that no debris is interfering with the flow of air. Inspect entire vent system for proper function.
Cleaning Logs
Use a soft brush attachment on a vacuum cleaner to gently remove dust or soot deposits from logs and burner.
Cleaning Glass Door Frequency: After the first 3 to 4 hours of use. As necessary after
initial cleaning.
By: Home owner. Task: Remove and clean glass after the first 3 to 4 hours of use.
After the initial cleaning, clean as necessary. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner.
NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners.
Glass Door Replacement
Do not operate the fireplace insert if the high-temperature ceramic glass is cracked or broken. Do not attempt to replace the ceramic glass panel. A complete replacement glass door assembly should be ordered as listed in the Parts List on page 25, if needed. Do not use substitute materials for replacement of glass door components. Do not abuse the glass door by striking the glass. Do not abuse the glass door by slamming or forcing the door shut. When installing the glass door assembly, place the top door flange over the firebox top, center left to right, then gently swing the door bottom inward and secure with the two (2) spring loaded door latches.
23015-6-0408Page 22
Decorative Mission Louver
Decorative Leaf Louver
Decorative Arch Louver
STD Louvers 45 Deg
STD Contemporary Surround
Cast Iron Traditional Surround
Bottom Cover
DECORATIVE ACCESSORIES
The following accessory parts can be obtained from your Empire Comfort Systems dealer. If you need additional information beyond what your dealer can furnish, contact Empire Comfort Systems Inc., Nine Eighteen Freeburg Ave., Belleville, Illinois 62220.
Black
Gold Finish
Hammered Pewter
Brushed Stainless
Black Black Black (Standard)
Black
Gold Finish
Hammered Pewter
Brushed Stainless
Black
Gold Finish
Hammered Pewter
Brushed Stainless
Gold Finish
Hammered Pewter
Brushed Stainless
Black Used to finish off bottom of insert and surround panels when installed in a fireplace without a flush hearth extension. Can be used with traditional cast iron or contemporary surround kits.
23015-6-0408 Page 23
INSERT PARTS VIEW
1
2
3
4
5
6
7
8
9
10
11
13
14
15
16
17
19
20
21
22
23
24
25
26
27
28
29
30
31
33
34
35
36
37
38
39
40
41
7
12
32
42
43
18
44
45
46
48
47
49
23015-6-0408Page 24
INSERT PARTS LIST
PART NUMBER INDEX NO. DV25IN33L(N,P) DV33IN33L(N,P) DV35IN33L(N,P) DESCRIPTION
1 22950 22950 22950 GUIDE, FLUE CONNECTOR 2 23309 23211 23211 VENT SLIDE PLATE ASSEMBLY 3 R9188 R9188 R9188 GASKET, TOP 4 R9192 R9196 R9199 BRICK PANEL, BACK 5 R9195 R9198 R9201 BRICK PANEL, RIGHT 6 R9194 R9197 R9200 BRICK PANEL, LEFT 7 20448 20448 20448 BRICK LINER BRACKET 8 22951 22972 22972 FIREBOX BAFFLE 9 22958 22976 22990 LOG SHELF 10 23303 23006 23320 GLASS DOOR & FRAME ASSEMBLY 11 23329 17169 17127 LOUVER ASSEMBLY 12 23158 23160 23160 LOG SUPPORT, FRONT 13 23315 23024 23024 GRATE TANG / BRACKET ASSEMBLY 14 R3435 R3435 R3435 WIRE ASSEMBLY 15 R3436 R3436 R3436 SWITCH, REMOTE/OFF/ON 16 R2708 R2708 R2708 IGNITER, PIEZO 17 23159 23161 23504 LOG SUPPORT, REAR 18 23521 23521 23521 FLAME SHIELD, RIGHT 19a R7612 R7612 R7612 PILOT ASSEMBLY, SIT (NAT) 19b R7611 R7611 R7611 PILOT ASSEMBLY, SIT (LP) 20 R9189 R9189 R9189 GASKET, PILOT 21 R5676 R5676 R5676 AIR SHUTTER 22 P253 P253 P253 FITTING, ORIFICE ANGLED 23a P286 P270 P244 ORIFICE, MAIN BURNER (NAT) 23b P214 P210 P245 ORIFICE, MAIN BURNER (LP) 24 23311 23017 23017 BURNER ASSEMBLY 25 22959 22959 22959 VALVE BRACKET 26 22739 22738 22738 TUBING ASSEMBLY 27 22973 22973 22973 SHIELD, VALVE 28a R7577 R7577 R7577 VALVE, SIT GAS (NAT) 28b R7578 R7578 R7578 VALVE, SIT GAS (LP) 29 22953 22953 22953 PIEZO BRACKET 30 16223 16223 16223 SPRING RETAINER ASSEMBLY 31 N/A 23690 23690 FLAME SHIELD, LEFT 32 M163 M163 M163 GASKET, FLUE CONNECTOR 33 23009 23009 23009 FLUE CONNECTOR ASSEMBLY 34 R9257 R9219 R9219 LOG, RIGHT FRONT 35 R9258 R9220 R9220 LOG, RIGHT CENTER 36 R9260 R9252 R9252 TWIG, RIGHT 37 R9261 R9253 R9253 TWIG, LEFT 38 R9255 R9217 R9217 LOG, BACK 39 R9259 R9251 R9251 LOG, LEFT CENTER 40 R9256 R9218 R9218 LOG, LEFT FRONT 41 R9268 R9268 R9268 WIRE ASSEMBLY - SWITCH 42 R2522 R2522 R2522 SWITCH, ON / OFF 43 18879 18879 18879 RHEOSTAT ASSEMBLY (SPEED CONTROL) 44 R7649 R7649 R7649 CONTROL, FAN 45 R9211 R9211 R9211 BLOWER ASSEMBLY (MOTOR W/HOUSING) 46 22954 22954 22954 BRACKET, BLOWER 47 R2204 R2204 R2204 CORD SET 48 R7591 R7591 R7591 FLEXLINE W/SHUTOFF VALVE 49 R9644 R9644 R9644 VIBRATION PAD
USE ONLY MANUFACTURER’S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.
23015-6-0408 Page 25
HOW TO ORDER REPAIR PARTS
Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer.
All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give all this information .
Fireplace Number Part Description
Fireplace Serial Number Part Number
Type of Gas (Propane or Natural)
Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.
Shipments contingent upon strikes, fires and all causes beyond our control.
Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-2623
SERVICE NOTES
23015-6-0408Page 26
SERVICE NOTES
23015-6-0408 Page 27
EMPIRE
EMPIRE
Comfort Systems
Empire Comfort Systems Inc. 918 Freeburg Ave. Belleville, IL 62220
If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer.
www.empirecomfort.com
23015-6-0408Page 28