EcoSmart EL40, EL60, EL80, EL100, EL120 Installation, Operation And Maintanance Manual

ELECTRIC SERIES
INSTALLER: Leave this manuaL with the appLiance. CONSUMER: Retain this manuaL foR futuRe RefeRence.
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
98.95kg, 218.15lbs
88.75kg, 195.66lbs
EL40
44kg, 97lbs
EL80
69.15kg, 152.34 lbs
EL60
55.65kg, 122.69lbs
pLease Read these instRuctions compLeteLy befoRe opeRating the ecosmaRt™ fiRe. faiLuRe to foLLow them couLd cause a heateR maLfunction ResuLting in seRious inJuRy and/oR pRopeRty damage.
WARNING: aLL eLectRic heateRs have hot and aRcing oR spaRking paRts inside. do not use it in aReas wheRe gasoLine, paint oR fLammabLe Liquids aRe oR aRe stoRed.
this fiRepLace meets the constRuction and safety standaRds of h.u.d. foR appLication in manufactuRed homes when instaLLed accoRding to these instRuctions.
www.ecosmartre.com
ENGLISH
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information, consult a
qualied installer.
CAUTION: Do not expose the heater to the elements (such as rain, etc).
Do not place clothing or other ammable material on or near rebox. Never place any objects on the replace.
Carefully supervise young children when they are in the room
with replace.
Fireplace becomes very hot when running. Keep children and adults away from hot surfaces to avoid burns or clothing
ignition. Fireplace will remain hot for a time after shutdown.
Allow surfaces to cool before touching.
CAUTION: In order to avoid overheating, do not cover the heater.
IMPORTANT INSTRUCTIONS
When using electrical heaters, basic precautions should always be
followed to reduce the risk of re, electric shock and injury to
persons, including the following:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9m) from the front of the heater and keep them away from the sides and rear.
3. Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect power at service panel and have heater inspected by a reputable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to o and turn o power to heater
circuit at main disconnect panel.
7. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock or re, or
damage the heater.
8. To prevent a possible re, do not block air intakes or exhaust in any
manner.
9. A heater has hot and arcing or sparking parts inside. Do not use it in
areas where gasoline, paint or ammable vapors or liquids are used or
stored.
10. Use this heater only as described in this manual. Any other use not
recommended by the manufacturer may cause re, electric shock or injury to persons.
11. Do not operate any heater with a damaged cord or plug or after the heater malfunctions, has been dropped or damaged in any manner.
Return heater to authorized service facility for examination, electrical or
mechanical adjustment, or repair.
12. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container.
13. Do not run cord under carpeting. Do not cover cord with throw rugs,
runners, or the like. Arrange cord away from trac area and where it will
not be tripped over.
14. Avoid the use of an extension cord because the extension cord
may overheat and cause a risk of re. However, if you have to use an
extension cord, the cord shall be No. 12 AWG minimum size and rated not less than 1500 watts.
15. SAVE THESE INSTRUCTIONS
© Copyright 2004 - 2017 EcoSmart Inc. All rights reserved. V02JN17
POWER DATA
PRODUCT GUIDE
BOX CONTENTS
EL40 EL60 EL80 EL100 EL120
Volts/HZ Amps AC 120V/60Hz
15 Amps
AC 120V/60Hz
15 Amps
AC 120V/60Hz
15 Amps
AC 120V/60Hz
15 Amps
AC 120V/60Hz
15 Amps
Heater AC 120V/60Hz
750W/1500W
AC 120V/60Hz
750W/1500W
AC 120V/60Hz
750W/1500W
AC 120V/60Hz
750W/1500W
AC 120V/60Hz
750W/1500W
Lamps LED 12V LED 12V LED 12V LED 12V LED 12V
Rotor motor AC 120V/60Hz 4W
CCW 15/18 r/min
AC 120V/60Hz 4W
CCW 15/18 r/min
AC 120V/60Hz 4W
CCW 15/18 r/min
AC 120V/60Hz 4W
CCW 15/18 r/min
AC 120V/60Hz 4W
CCW 15/18 r/min
Shipping Size 58” x 26” x 14”
1473mm x 660mm x
356mm
78” x 26” x 14”
1981mm x 660mm
x 356mm
98” x 26” x 14”
2489mm x 660mm
x 356mm
118” x 26” x 14”
2997mm x 660mm
x 356mm
138” x 26” x 14”
3505mm x 660mm
x 356mm
Model Viewing Area Firebox Dimensions Framing Dimensions
EL40 40” W x 15” H
1016mm W x 381mm H
54 3/4” W x 22 1/2” H x 11 1/2” D
1391mm W x 572mm H x 292mm D
55 3/4” W x 23” H x 12” D
1416mm W x 548mm H x 305mm D
EL60 60” W x 15” H
1524mm W x 381mm H
74 3/4” W x 22 1/2” H x 11 1/2” D
1899mm W x 572mm H x 292mm D
75 3/4” W x 23” H x 12” D
1924mm W x 548mm H x 305mm D
EL80 80” W x 15” H
2032mm W x 381mm H
94 3/4” W x 22 1/2” H x 11 1/2” D
2407mm W x 572mm H x 292mm D
95 3/4” W x 23” H x 12” D
2432mm W x 548mm H x 305mm D
EL100 100” W x 15” H
2540mm W x 381mm H
114 3/4” W x 22 1/2” H x 11 1/2” D
2915mm W x 572mm H x 292mm D
115 3/4” W x 23” H x 12” D
2940mm W x 548mm H x 305mm D
EL120 120” W x 15” H
3048mm W x 381mm H
134 3/4” W x 22 1/2” H x 11 1/2” D
3423mm W x 572mm H x 292mm D
135 3/4” W x 23” H x 12” D
3448mm W x 548mm H x 305mm D
1 x Remote
Electric Access Plate (see page 6)
L Metal Nailing Flanges
Glass Pull Tabs
Width varies (see chart below)
1/2” (13 mm)
Drywall
Stop x 4
1/2” (13 mm) Drywall Stop x 4
11 1/2” (292mm)
(all models)
22.5” (572 mm) (all models)
1 x Fire Unit
1 x L Metal Deco Trim
PRODUCT SPECIFICATIONS
3 x L Metal Nailing Flanges (with screws)
1 x Tethered Wall Control
Glass Media
*The number of bags vary by model.
HEAT
www.ecosmartre.com
ENGLISH
CAUTION: Do not locate in a moist room such as a bathroom or
laundry room.
CAUTION: Wear gloves and safety glasses for protection during installation and mainte-nance.
INSTALLATION
WARNING: If the information in these instructions is not
followed exactly, a re or explosion may result casing property
damage, personal injury or death.
WARNING - RISK OF FIRE! To prevent a possible re, do not block air intake or exhaust in
any manner. Do not use on soft surfaces where openings may
become blocked.
WARNING - RISK OF FIRE! Do not blow or place insulation against the rebox.
To reduce the risk of re do not store or use gasoline or other ammable vapors in the vicinity of this or any other heater.
CAUTION: Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet (0.9m) from the front of the heater and keep them away from
the sides and rear.
INSTALLING FIREPLACELOCATING FIREPLACE
Select a suitable location that is not susceptible to moisture and is a
safe distance from drapes, furniture and high trac areas. A qualied electrician should add a exible 15 amp 120 volt circuit per local
building codes.
Note: Follow all national and local electrical codes.
© Copyright 2004 - 2017 EcoSmart Inc. All rights reserved. V02JN17
2. Install L Metal Nailing Flanges
3. Connect hard wire to the terminal block according to the diagram below. Choose any connector type according to local building code.
1. Prepare the framed opening using wood or metal studs according to
the Framing Dimensions chart
4. Install the re unit in the framed opening with a minimum 1 ¼ (32mm)
drywall screws to secure the unit.
5. Mask the exposed re unit during the drywall process. Install drywall to the drywall stops on the perimeter of the re insert. For more
information on the drywall stops see the Product Guide on page 3. Decorate as desired.
6. After installation, user may elect to use the L Metal Deco Trim. To install, use a small amount of construction adhesive and secure to the drywall face.
INSTALLATION
H
W
D
To be performed by a qualied electrician according to local building codes.
Terminol Block
FRAMING DIMENSIONS
Model W H D
EL40 55 3/4” (1416mm) 23” (584mm) 12” (305mm)
EL60 75 3/4” (1924mm) 23” (584mm) 12” (305mm)
EL80 95 3/4” (2432mm) 23” (584mm) 12” (305mm)
EL100 115 3/4” (2940mm) 23” (584mm) 12” (305mm)
EL120 135 3/4” (3448mm) 23” (584mm) 12” (305mm)
www.ecosmartre.com
ENGLISH
OPTIONAL INSTALLATIONS Installing the Wired Touch Control
1. Locate and remove the access door on the rear right side of the
re unit.
2. Locate the Wired Touch Control directly inside the access panel. Pull
the touch control through the access panel and replace the access door. Locate the touch control anywhere within cable length.
3. The wiring of the Wired Touch Control cannot be located near high
voltage wires (110V) as this may eect performance of the touch
control. Keep all high voltage power at least 12” (305mm) from the touch control and touch control wiring. The touch control includes 12 feet of wiring. Do not add or remove or cut the wiring.
Indicator Lights
When all indicator lights are o, touching any button will only show the
status. Once the indicator lights are on you can begin operation. Touch the power button to turn the machine on. This will be indicated by 1 orange LED light. The Heat button can be pressed multiple times and
will turn on low, high and o in that order. The Backlight button turns on high, medium, low and o in that order.
The unit is hardwired and has no main switch. (Caution: If servicing this
unit, turn o power at the main circuit breaker.) An optional tethered
wall control switch is included, refer to installation instructions to relocate the tethered wall control switch to a wall location.
The included Wired Touch Control functions in the same manner as the buttons on the tethered wall control switch.
INSTALLATION
The status light above shows that the power is on and the heater is on low.
The status light above shows that the power is on and the heater is on high
When the switch turns on, this orange
pilot lamp is always on. It shows the re is
energized.
Power
Heat
Backlight
© Copyright 2004 - 2017 EcoSmart Inc. All rights reserved. V02JN17
HEAT
OPERATION
Installing Optional Log Set
1. Remove the inner glass panel by rst removing the 2 screws in the nger pull tabs (nger pull tabs are located on the top of the glass
panel.) Tilt the glass face down about 45 degrees and remove the glass. Store the glass panel upright (not on it’s face) in a safe place.
CAUTION: There are locator pins on the bottom of the glass panel.
Lift gently to avoid damaging the pins and unit face
2. Follow the instructions included with the optional log set.
Finger pull tabs
1. Press to turn unit on / o
2. Press to dim ame
3. Press to change ame from
orange to blue
4. Press to brighten ame
1
2
3
4
Remote
The On/O button toggles the unit on or o. The Color button toggles the ame image from orange to blue. The Dimmer button will lower the brightness of the ame, the Bright button will make the re image
brighter. Press the Heat down arrow to set the heat to low, press the Heat up arrow to set the heat to high. Press either of these buttons
twice to turn the heat o.
www.ecosmartre.com
ENGLISH
MAINTENANCE
ITEM PHOTO DESCRIPTION
ESF.1.EL.P.PCB
Electric Printed circuit board
ESF.1.EL.P.LCD
Electric LCD Touch Control
ESF.1.EL.P.REM.IRC
Electric Remote Control IR Receiver
ESF.1.EL.P.TRA
Electric Transformer
ESF.1.EL.P.HF.RH
Electric Right hand Heater Fan
ESF.1.EL.P.HF.LH Electric Left hand Heater Fan
ESF.1.EL.P.HTR
Electric Heater
ESF.1.EL.P.MTR
Electric Spindle Motor
ESF.1.EL.P.LED40
Electric LED 40
ESF.1.EL.P.LED60 Electric LED 60
ESF.1.EL.P.LED80 Electric LED 80
ESF.1.EL.P.LED100 Electric LED 100
ESF.1.EL.P.LED120 Electric LED 120
ESF.1.EL.P.REM
Electric Remote Control
ESF.1.EL.P.GL40
Electric Innerglass 40
ESF.1.EL.P.GL60 Electric Innerglass 60
ESF.1.EL.P.GL80 Electric Innerglass 80
ESF.1.EL.P.GL100 Electric Innerglass 100
ESF.1.EL.P.GL120 Electric Innerglass 120
ESF.1.ELP.TWS
Electric Wired Touch Control
SERVICE PARTS
© Copyright 2004 - 2017 EcoSmart Inc. All rights reserved. V02JN17
MAINTENANCE
ITEM PHOTO DESCRIPTION
ESF.1.EL.P.MDT40
Electric Metal Deco Trim 40
ESF.1.EL.P.MDT60 Electric Metal Deco Trim 60
ESF.1.EL.P.MDT80 Electric Metal Deco Trim 80
ESF.1.EL.P.MDT100 Electric Metal Deco Trim 100
ESF.1.EL.P.MDT120 Electric Metal Deco Trim 120
FREQUENTLY ASKED QUESTIONS
Q. How do you program the remote control? A. The remote comes pre-programmed. No programming is necessary.
Q. What distance can the remote be used from the replace?
A. Optimal distance for the remote control is within 20 feet (6 meters) of
the replace.
Q. Can you turn on the replace via the touch screen and o via the
remote (or vise versa)?
A. Yes.
Q. How long will the LED lights last? A. LED Lamps have a life span of up to 20 years.
Q. Can the sensitivity of the touch screen be adjusted? A. Yes, but only by the factory. Not just any technician will be able to
adjust the touch screen sensitivity.
Q. Can the replace be installed outside?
A. No. Please review the entire safety chapter before installing this
replace.
Q. Does the replace need to be on a dedicated 15 amp circuit?
A. Yes.
Q. What thickness of sheetrock should be used for the recessed
installation?
A. 1/2” (13mm) or 5/8” (16mm).
Q. How often do the batteries in the remote need to be replaced? A. Annually, possibly more with heavy use.
Q. Is there a remote receiver in the replace that requires batteries? A. No, only the remote transmitter requires batteries. The rest of the
replace operates entirely o the main power supply
www.ecosmartre.com
ENGLISH
MAINTENANCE
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Flame is not visible when unit is turned on
A. Wiring is loose
A. Disconnect unit from power source and inspect for loose connections
B. Motherboard is defective B. Replace motherboard
Fireplace lights up but there is no ame image
A. Wiring for motor is loose
A. Disconnect unit from power source and inspect for loose connections from motor
B. Motor is defective B. Replace motor
Fireplace is squeaking when ame image is on
A. Fireplace spindle/ rod is contacting to metal
A. Apply lithium grease or any standard grease to contacts with rod and metal
B. Motor is defective B. Replace motor
Nothing comes on (touch screen, etc.)
A. Breaker tripped or circuit has no power
A. Reset breaker, test circuit for power
B. Internal component is frozen and needs to be reset
B. Turn power o at the main breaker for 20
seconds. Turn power back on.
C. Defective component
C. Qualied service technician needs to re­place motherboard, transformer or LCD touch control.
Touch Screen Comes on - then nothing
A. Fireplace is not plum to the wall (there is space between the touch screen and fascia)
A. Reposition the replace in the installation so the glass fascia rests rmly to the replace
touch controls. Check that fascia is seated correctly on pins
B. Fireplace was installed with the power in “on” position
B. Turn the main breaker to the “o” position for 30 seconds. Next ip the breaker back into
the “on” position for 20 seconds for complete reboot of touch control.
C. Not operating touch control properly with
nger
C. Press at part of nger rmly on the touch
screen and apply moderate pressure
D. Loose connection on motherboard
D. Check functions with remote control. if functional, check connections on motherboard
E. Motherboard is defective E. Replace Motherboard
Fireplace turns o and will not turn back on
A. Fireplace has overheated and safety disc has snapped or circuit breaker has tripped
A. Turn the main circuit breaker to the “o”
position for 30 seconds. Next, turn the breaker back to the “on” position. Unit will reboot and safety disc will reset. Ensure there are no obstructions to the air inlet or air outlet
areas around the replace.
Can operate replace functions with touch
controls but not remote control
A. Low Batteries
A. Replace batteries in remote control with 2 AA batteries
B. Not aiming control correctly
B. Aim remote control to the upper right of the viewing area where sensor is located
C. Remote control defective C. Replace remote control
D. Remote Sensor is defective D. Replace remote sensor inside replace
Heater does not provide heat when on
A. Wiring is loose
A. Disconnect unit from power source and inspect for loose connections
B. Thermal snap disc has been tripped
B. Turn the main breaker to the “o” position for 30 seconds. Next ip the breaker back into
the “on” position.
C. Heater core is defective C. Replace Heater Core
TROUBLESHOOTING
© Copyright 2004 - 2017 EcoSmart Inc. All rights reserved. V02JN17
MAINTENANCE
CLEANING AND MAINTENANCE INSTRUCTIONS
There is very little maintenance involved with your electric replace.
Please follow the few points below:
• On a semi-annual basis unplug the machine from it’s power source
and wait for the heating element to cool, remove the glass face of
the replace and dust the re unit with a dry cloth. Be careful not to
brush any wires that may be exposed as you do this.
• To clean the glass face of the replace simply use your desired glass
cleaner with paper towels.
• To clean the air inlets/outlets, wipe with a soft cloth or the nozzle of a
vacuum cleaner
• Dust can easily build up around the heater area under the appliance.
Take particular care to clean this area on a regular basis to prevent buildup.
WIRING DIAGRAM
EcoSmart Inc.
5875 Green Valley Circle, Suite 100 Culver City, CA 90230 P + 1 (888) 590.3335 E info@ecosmartre.com
V02JN17
Loading...