EcoSmart Burner One, Burner Two, XL900 Burner, XL700 Burner, Around Burner Installation, Operation And Maintenance Manual

...
Burner Kits INSTALLATION, OPERATION AND MAINTENANCE MANUAL
www.ecosmartre.com
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Burner Kits
Burner One Burner Two XL900 Burner XL700 Burner
Triple BurnerAround Burner
ENGLISH Burner Kits
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Please read these instructions completely before operating the EcoSmart™ Fire.
1
DEUTSCH Burner Kits
INSTALLATION, OPERATION AND MAINTENANCE MANUAL Bitte lesen Sie diese Anweisungen vor der Inbetriebnahme des EcoSmart™ Fire vollständig durch.
23
1 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V7 0910.
Testing and Compliance Statement
The EcoSmart™ Fire Collection has achieved Swedish Institute for Technical Approval in Construction (SITAC) approval.
EcoSmart Fire is TÜV certied in Germany when using Burner Two within a Firebox setting. For further information, please contact your distributor.
Instructions and specications for the EcoSmart™ Fire were tested as far as practicable to a selection of clauses from AS4553/AG103 – Australian Standard for Gas Space Heaters (closest comparable product at the
time of invention).
DANGEROUS GOODS
Denatured Ethanol is classied as a Flammable Liquid Class 1B (for Flammability) and Class 3 PGII (for Transportation) and is regulated by various standards around the world. You must familiarise yourself and
comply with these regulations in order to safely and legally store, handle, decant and use this fuel.
Reproduction of this manual in any manner, in any language, in whole or in part without prior written permission is prohibited. The Fire Company Pty Ltd reserves the right to correct any errors or misprints. We also reserve the right to alter information without notication. The information provided herein is believed to be correct but is not guaranteed.
International Patent Pending – Trademarks Pending – All Designs Registered.
ENGLISH
www.ecosmartre.com 2
ENGLISHContents
Contents
Conditions of Use 2
Warnings 3
Standard Equipment Received 4
Clearances & Installation
Ventilation & Efciency 9
How to operate the EcoSmart™ Fire 10
Purchasing your Denatured Ethanol*
Decanting your Denatured Ethanol* into the Jerry Can
Volume markings on the EcoSmart™ Burner – Slider position markings X
Decanting the fuel from the Jerry Can into the EcoSmart™ Burner
Lighting the EcoSmart™ Burner X
Regulating the ame X
Turning your EcoSmart™ Fire Off - Extinguishing the ame X
Re-igniting the EcoSmart™ Fire X
Maintenance Instructions X
Troubleshooting X
Your Warranty X
After Sales Service X
3
4
5 - 6
7 - 10
11 - 12
13
13
13
14
15
16
16
16
17
18
19
20
21
3 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V7 0910.
Conditions of Use
Congratulations on your purchase of the EcoSmart™ Fire.
The Fire Company Pty Ltd is very safety conscious. We have taken every care in designing, manufacturing and assembling your EcoSmart™ Fire to ensure it operates effectively, efciently, and safely. In return, we ask that you exercise care when using this product and follow the instructions below:
1. Before using your EcoSmart™ Fire please read all the information contained in this Installation, Operation and Maintenance Manual very carefully. It explains exactly what you need to do in order to use the product
safely and effectively.
Failure to follow these instructions could result in property damage, bodily injury or even death.
2. Children do not recognize the dangers that can arise when handling Dangerous Goods, nor do they recognize the volatility of ammable liquids when ignited. Please ensure you keep children at a safe distance and supervised at all times when operating the re.
3. For the purposes of this manual we refer to the fuel used in the EcoSmart™ Fire as Denatured Ethanol*.
*Some fuels are better than others, it’s important to source information on the best fuel in your area
from your local retailer/distributor. Visit www.ecosmartre.com to nd out what Denatured Ethanol
is called around the world.
Denatured Ethanol* is classied as a Dangerous Goods Flammable Liquid Class 3, PGII and is regulated by specic standards and rules. You must familiarise yourself with the appropriate
regulations of your country in order to safely and legally store, handle, decant and use this fuel.
The customer warrants to The Fire Company Pty Ltd that after delivery of their EcoSmart™ Fire and whilst
The Fire Company Pty Ltd retains any interest in the goods or consigned goods (as the case may be) the customer shall comply with all applicable Acts, Regulations and Laws dealing with the transport, unloading and storage of Dangerous Goods.
4. Approval from building authorities may be required. Please ensure you contact the appropriate parties before installing your EcoSmart™ Fire.
5. It is a condition of purchase that you obtain a re extinguisher ABC Monoammonium Phosphate type. These can be purchased from your distributor or independently.
6. A smoke alarm is a valuable and necessary building code requirement and an element that is compulsory in some countries for your insurance coverage. For protection against any form of re, not just your EcoSmart™ Fire, ensure you install a smoke alarm.
7. Pebbles or other refractory decorative re accessories should not be placed directly over the EcoSmart™ Burner mouth or in a manner that they interfere with the ame.
If using decorative re accessories you must:
- Ensure the decorative re accessories do not interfere with the sliding mechanism.
- Conrm quality and suitability of these re accessories to ensure they will not explode, emit carbon monoxide or fumes when exposed to extreme temperature variations.
- The re accessories must have a minimum overall size of 70mm [2.75in] so they cannot fall in the EcoSmart™ Burner at any time.
8. EcoSmart™ Burners must incorporate a protective “Twin Skin” into their setting (Note: Not applicable for
the Around Burner). The incorporation of a Top Tray (“Twin Skin”) into your setting protects against heat
transference and aids in the collection of any accidental spillage.
The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of top trays
not manufactured by The Fire Company Pty Ltd;
If you have any questions about your EcoSmart™ Fire or anything in this manual please contact your local distributor or retailer or visit www.ecosmartre.com
ENGLISH
Conditions of Use
www.ecosmartre.com 4
Warnings
1. Risk of explosion:
a) Never use any fuel other than the fuels specically identied for use in the appliance.
Never use gasoline.
b) Never ll the fuel reservoir when it is operating or still hot.
Wait up to 30 minutes after operating the replace before relling.
c) Never ll fuel reservoir in areas where ammable vapours or gas may be present.
d) Never store or transport the fuel in other than a metal or plastic container that is:
1. Acceptable for use with the specic fuel.
2. Is in the original container for the alcohol fuel.
2. Never store fuel in the living space where the re is situated.
3. Due to high surface temperatures, keep children, pets, clothing, and furniture away. The unit is hot while in operation, contact with the EcoSmart™ Fire may cause skin burns.
4. Open res consume oxygen and contain the risk of indoor air pollution. Use EcoSmart™ Fires only in
well-ventilated areas. Improper ventilation can cause serious injury or death. People with breathing problems should consult a physician before using the appliance. Refer ventilation information on page 12.
5. Do not use the EcoSmart™ Fire to heat or boil water or as a cooking appliance. Do not put wood, charcoal, paper or other combustible objects in the EcoSmart™ Fire.
6. EcoSmart™ Fires have not been tested with an unvented gas log set. To reduce the risk of re or
injury, do not install an unvented gas log set into this appliance.
7. The EcoSmart™ Fire has not been tested for use with doors. To reduce the risk of re or injury, do
not install doors.
8. It is recommended that the EcoSmart™ Fire be xed into position to avoid displacement as per
instruction provided with each model.
9. Do not dismantle the EcoSmart™ Burner.
10. Do not attach any other tank to the EcoSmart™ Burner.
11. Do not obstruct the open/close sliding mechanism of the EcoSmart™ Burner in any way as this could result in the jamming/non functionality of the shut off mechanism.
12. The shut off mechanism on the burners will become very hot during operation and will stay hot for up to 30 minutes. To avoid injury, do not touch with any parts of your body nor with any
combustible materials such as matches or ammable liquids. Always use the lighting rod provided
with your EcoSmart™ Fire to open or close the shut off mechanism.
13. The EcoSmart™ Burner should not be started if a fault is suspected or when there appears to be any damage to the burner or its housing.
14. Using the EcoSmart™ Burner without the Top Tray (Twin Skin) can result in overheating of the material which surrounds the burner. (Note: Not applicable for the Around Burner)
15. EcoSmart™ Fires must only be operated using authorised accessories & equipment.
16. EcoSmart™ Fire recommends that you use only certied EcoSmart™ Fire screens to prevent
injuries to children and pets. Children and pets should always have adult supervision and not be
left alone in a space when the replace is operating or is still hot.
17. For maximum safety, only use the lighting rod and the lighter provided with your EcoSmart™ Fire
to ignite the replace. Using matches or other lighters can result in serious injury. Do not smoke while igniting the re or within 1500mm [59.1in] of operating the replace.
18. The use of any tting other than those available from or recommended by The Fire Company Pty Ltd
for the EcoSmart™ Firebox and Burner is not permitted.
19. Make sure that there is always an air gap of 20mm [0.8in] around the Firebox for ventilation. Do not pack air gaps with insulation or other materials and do not remove air spaces.
ENGLISH
5 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V7 0910.
WarningsENGLISH
20. The Fire Company Pty Ltd does not accept responsibility for any damage which occurs if the EcoSmart™ Fire is used for purposes other than those for which it is intended, or if it is incorrectly
operated or repaired by unqualied persons.
21. The EcoSmart™ Fire is not intended to operate continuously. To avoid heat expansion and potential splitting of the timber framework in Designer Range models please ensure that the model is allowed to cool down completely for 3 hours after use.
22. The Fire Company Pty Ltd recommends that the quantity of Denatured Ethanol poured into the
burner be burnt until empty rather than extinguishing the re early. Extinguishing the re early
will result in a larger amount of residual fumes in the EcoSmart™ Burner and a more volatile re­ignition.
When fumes are combined with excess fuel it could be a hazardous to people who are unaware of
the EcoSmart™ Fire operation and its condition of use (e.g smokers). Ensure only those who have read the instructions attempt to operate the burner.
23. An inherent danger with denatured ethanol is that the ame produced is almost invisible in normal daylight conditions or rst lit. Being difcult to see, an inexperienced person can easily assume the burner is empty and needs lling. It is potentially lethal to attempt to rell the EcoSmart™
burner when it is still lit. The result could easily be an explosion.
If it is necessary to rell the burner, assume it is still burning and go through the normal procedure of
pushing the slider to the off position using the lighting rod to extinguish the re as instructed on page
17. Wait 30 minutes after the re has died, then check carefully if the burner is at room temperature, before relling and follow the instructions on page 16 carefully.
24. NEVER leave a re unguarded.
If you have any questions regarding any of the above important safety information please contact your distributor or The Fire Company Pty Ltd.
Please store these warnings in a safe place for future reference.
Warnings
www.ecosmartre.com 6
Standard Equipment Received
Standard Equipment Received
Please ensure that all items have been received. The Burner Kit includes the minimum equipment required
to operate the EcoSmart™ Fire safely.
Accompanying Compulsory Accessories
Burner Kits Top Tray Manual Jerry Can Lighting Rod Lighter
1 x Burner One 1 1 1 1 1
1 x Burner Two 1 1 1 1 1
1 x XL900 Burner 1 1 1 1 1
1 x XL700 Burner 1 1 1 1 1
1 x Around Burner NA 1 1 1 1
1 x Triple Burner 1 1 3 1 1
Burner
The Burner is the core product of the EcoSmart™ Fire being the chamber that houses the fuel.
Burner One
h 112mm x w 290mm x d 290mm h [4.4in] x w [11.4in] x d [11.4in]
Burner Two
h 78mm x w 290mm x d 290mm h [3.1in] x w [11.4in] x d [11.4in]
XL900 Burner
h 119mm x w 908mm x d 193mm h [4.68in] x w [35.7in] x d [7.6in]
XL700 Burner
h 119mm x w 700mm x d 193mm h [4.68in] x w [27.56in] x d [7.6in]
Around Burner
h 156mm x 366 h [6.2in] x [14.4in]
Triple Burner
h 114mm x w 901mm x d 320mm h [4.5in] x w [35.7in] x d [12.6in]
ENGLISH
7 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V7 0910.
Standard Equipment ReceivedENGLISH
All EcoSmart™ Burners must incorporate a protective “Twin Skin” into their setting. Off the shelf models from the Designer Range, Renovator Range and Grate Range include a built in “Twin Skin” and therefore will not include a Top Tray as an accessory. (NOTE: Not applicable for the Around Burner.)
Burner One Top Tray
h 114mm x w 320mm x d 320mm [4.5in] x [12.6in] x [12.6in]
XL900 Burner Top Tray
h 103.8mm x w 899mm x d 184mm h [4.1in] x w [35.4in] x d [7.2in]
XL700 Burner Top Tray h 103.8mm x w 691mm x d 184mm h [4.1in] x w [27.2in] x d [7.2in]
Burner Two Top Tray h 114mm x w 320mm x d 320mm h [4.5in] x w 12.6in] x d [12.6in]
Triple Top Tray h 114.2mm x w 901mm x d 320mm h [4.5in] x w [35.5in] x d [12.6in]
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Please read these instructions completely before operating the EcoSmart™ Fire.
Burner Kits
Burner One Burner Two XL Burner Triple Burner Around Burner
Installation, Operation and Maintenance Manual
In order to obtain optimal and safe results from your EcoSmart™ Fire, we recommend carefully reading the
entire instruction manual.
297mm x 210mm x 8mm [11.7in] x [8.3in] x [0.3in]
Jerry Can with Spill Proof Spout (CARB Regulation compliant)
This 4.75 Litres [11⁄4 Gal] Jerry Can has been chosen for its unique safety features. It provides an automatic
stop ow, a fast ow rate, a locking thumb button control, and a self-venting system. The Jerry Can will allow
safe storing/decanting of the Denatured Ethanol* used for the EcoSmart™ Fire.
Due to safety regulations the Jerry Can provided with this package comes without fuel.
220mm x 185mm x 235mm [8.7in] x [7.3in] x [9.3in]
Lighting Rod
This long slender piece of stainless steel with a small return at the end enables you to safely adjust the slider position on the EcoSmart™ Burner at any time. It is also used for the ignition procedure.
657mm x 28mm x 23mm [25.9in] x [1.1in] x [0.9in]
Lighter*
This rellable butane lighter perfectly compliments the modern style of the EcoSmart™ Fire as well as
supporting the safe ignition of the lighting rod. The length of the lighter further enhances the management of the lighting process.
* Due to safety regulations the butane lighter provided with this package comes without fuel. Small re-charge cans of butane gas with the necessary connections can be purchased from your hardware store. Lighter image is indicative only, the model included may vary from time to time.
185mm x 15mm x 15mm [7.3in] x [0.6in] x [0.6in]
www.ecosmartre.com 8
ENGLISHClearances & Installation
Clearances & Installation
The installation & clearances guidelines below are provided as a general overview only. Detailed installation specications are available for each individual model of the EcoSmart™ Fire range and should have been referred to and taken into account prior to your purchase. To ensure the installation complies with our Compulsory Installation & Clearance Requirements please contact The Fire Company Pty Ltd or one of its representatives for a copy of the relevant specication to be sent to you.
The Around Burner is primarily intended for outdoor use. All other Burners are primarily intended for indoor use, however when any Burner is used outdoors, it is important that the Burner be positioned in a large open space ensuring that the nearest combustible (trees, branches, umbrellas, ceilings etc) are a minimum of 2000mm [78.74in] away in all weather conditions (for example, on windy days where there is movement in branches, the clearance must still be met). When not in use it is recommended that you protect the model from water damage or corrosion by covering. Burner Covers are available. When used indoors, ensure that the mouth of the ame is positioned a minimum of 1500mm [59.1in] away from curtains, ammable materials and other sources of ignition. Be aware of drafts.
Clearances
INSERTING WITHIN A FIREBOX SETTING The EcoSmart™ Burner can only be tted into a rebox that has minimum clearances as outlined below.
Burner Kits
Metric mm / Imperial [in]
Firebox Width Firebox Depth Overhead Rear Front
Burner One & Burner Two
650
[25.6]
365
[14.4]
650
[25.6]
30
[1.2]
45
[1.8]
XL900 Burner
1100
[43.3]
350
[13.78]
500
[19.7]
40
[1.6]
50
[2.0]
XL700 Burner
900
[35.4]
350
[13.78]
500
[19.7]
40
[1.6]
50
[2.0]
Around Burner
650
[25.6]
365
[14.4]
650
[25.6]
30
[1.2]
45
[1.8]
Triple Burner
1200
[49.6]
500
[19.7]
750
[29.5]
40
[1.6]
65
[2.6]
Custom made reboxes must:
- be made out of a non-combustible material such as stainless steel;
- be constructed to accommodate a Top Tray or “Twin Skin” (NOTE: Not applicable for the Around Burner);
- have built in spacers of 20mm [0.8in] on all sides to ensure that it does not sit directly against any combustible materials and an air gap is incorporated for insulation around the box construction.
The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of custom made or privately commissioned Fireboxes.
Burner One & Burner Two
XL900 Burner XL700 Burner
Around Burner
Triple Burner
9 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V7 0910.
Clearances & Installation
INSERTING WITHOUT A FIREBOX SETTING: When creating a custom built setting the following dimensions must be adhered to at all times.
The Fire Company Pty Ltd recommends using the Burner in a rebox manufactured by The Fire
Company Pty Ltd only. The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of custom made or privately commissioned Fireboxes.
A re extinguisher is a compulsory accessory.
Burner Kits Overhead
Metric mm
Imperial [in]
Front
Metric mm
Imperial [in]
Sides
Metric mm
Imperial [in]
Rear
(Only if Non-combustible)
Metric mm
Imperial [in]
Nearest
Combustible Radius
Metric mm
Imperial [in]
Burner One & Burner Two
1500
[59.1]
45
[1.8]
600
[23.6]
30
[1.2]
600
[23.6]
XL900 & XL700 Burners
1500
[59.1]
65
[2.6]
600
[23.6]
40
[1.6]
600
[23.6]
Around Burner
2000
[78.7]
45
[1.8]
600
[23.6]
30
[1.2]
600
[23.6]
Triple Burner
1800
[70.9]
65
[2.6]
600
[23.6]
40
[1.6]
600
[23.6]
Warning: The rear wall should be a non combustible material. If the rear wall is combustible, a distance of 600mm [23.6in] must be allowed for.
ENGLISH
CONVERTING AN EXISTING FIREPLACE: If inserting an EcoSmart™ Burner into an existing masonry replace, utilise the damper within the existing replace in order to keep the heat from escaping through the ue.
min
[23.6]
600mm
min
[23.6]
600mm
min [1.2]
30mm
min [1.8]
45mm
min
[23.6]
600mm
Around Burner Triple Burner
XL900 and XL700 BurnersBurner One & Burner Two
www.ecosmartre.com 10
ENGLISHClearances & Installation
Installation Requirements
There are many different variations available for installing the EcoSmart™ Burner. In all cases, the EcoSmart™ Burner must:
- be installed into non-combustible material ONLY – for example stainless steel, concrete, brick, stone;
- only be installed after all gas connections or pipelines in the area are disconnected and made safe by an appropriately qualied and licensed professional;
- be installed into a xed and secure position before lling, lighting and operating;
- be operated in a xed position. EcoSmart™ Burners are not meant to be relocated as relocating creates the risk of accidental fuel spillages. If you relocate the Burner, make sure that there is no accidental
spillage before you ignite the Burner. The Fire Company Pty Ltd is not liable for any damages arising from fuel spillages due to relocating the Burner;
- be installed into a level platform;
- not be installed directly beside or near wallpaper, laminate, veneer or any surface that has not been re rated (the heat will impact the material). Refer to product specication of wallpaper, laminate, veneer or glue for heat tolerances;
- be installed into a setting that has a straight back – the incorporation of angled backs alters the aerodynamics of the ame environment and could lead to an unstable ame behaviour;
- be tted within a “Twin Skin”, such as a Top Tray (NOTE: Not applicable for the Around Burner).
- be positioned so the mouth of the ame is a minimum of 1500mm [59.1in] away from curtains, ammable materials and other sources of ignition. Be aware of drafts.
As a general guide we recommend that:
- any furniture items or ttings directly above or beside the EcoSmart™ Fire installation be deemed suitable for heat tolerances by their manufacturer e.g Plasma Screens, wallpaper, laminates, veneers, glues, reconstituted materials;
- a heat reective panel made of non combustible material (ideally stainless steel) be installed as the surround and top of the replace setting to assist in heat distribution. The Fire Company Pty Ltd is not
liable for any injuries or damages sustained through the use of panels not manufactured by The Fire Company Pty Ltd;
- glass or mirrored surfaces near the EcoSmart™ Fire installation must be toughened.
SPACERS: All Burners have built in spacers on all external sides. Do not pack with insulation or other materials, as the air spacers are required for ventilation.
A re extinguisher is a compulsory accessory.
11 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V7 0910.
Clearances & Installation ENGLISH
Top Tray
The incorporation of a Top Tray (“Twin Skin”) into your setting protects against heat transference and aids in the collection of any accidental spillage. If utilising one that is not supplied by The Fire Company Pty Ltd then it must undergo a “water tight” test prior to inserting the EcoSmart™ Burner into place.
The Fire Company Pty Ltd is not liable for any injuries or damages sustained through the use of Top Trays not manufactured by The Fire Company Pty Ltd;
When installing multiple Burners a maximum of three (3) Burners may be installed into the one “Twin Skin” (excluding the XL Burner which can only have one (1) Burner per Top Tray). It is imperative that when installing multiple burners you consider strongly the impact of any accident and minimise it wherever possible.
The Top Tray (“Twin Skin”) when included with the Burner Kits are to be tted directly into the burner shelf from above. The Burner is then inserted into the Top Tray setting and sits ush - as illustrated below.
The size of the cut-out should not give more than 5mm [0.196in] clearance.
Cut Out
Top Tray
[35]
888mm
[6.8]
173mm
[4.24]
107.9mm
XL Burner
Cut Out
Top Tray
[26.7]
680mm
[6.8]
173mm
[4.24]
107.9mm
XL Burner
Around Burner
CutOut
min
[12.6]
320mm
min
[6.3]
160mm
Around Burner: A Top Tray is not required. The
Around Burner tray is “formed” which
eliminates the need for welding and
therefore the risk of leaks.
Cut Out
Top Tray
[34.6]
880mm
[11.7]
298mm
[4.7]
120mm
Triple Burne
r
Burner Kits Cut Out Dimensions (SUPPLIED Top Tray)
Height x Width x Depth - Metric mm, Imperial [in]
Cut Out Dimension (EXCLUDING SUPPLIED Top Tray)
Height x Width x Depth - Metric mm, Imperial [in]
Burner One
120 x 298 x 298 [4.7 x 11.7 x 11.7]
120 x 275 x 275 [4.7 x 10.8 x 10.8]
Burner Two
120 x 298 x 298 [4.7 x 11.7 x 11.7]
120 x 275 x 275 [4.7 x 10.8 x 10.8]
XL900 Burner 123 x 888 x 173 [4.8 x 35 x 6.8] 120 x 885 x 166 [4.7 x 34.8 x 6.5]
XL700 Burner 123 x 680 x 173 [4.8 x 26.7 x 6.8] 120 x 677 x 166 [4.7 x 26.6 x 6.5]
Around Burner NA 160 x 320 x 320 [6.3 x 12.6 x 12.6]
Triple Burner 120 x 880 x 298 [4.7 x 34.6 x 11.7]
All setting must incorporate the supplied Triple Tray
XL900 Burner
XL700 Burner
www.ecosmartre.com 12
ENGLISHVentilation & Efciency
Ventilation
& Efciency
Ventilation
EcoSmart™ Fires do not require any form of permanent xture or tting, such as a ue for ventilation, a permanent connection or any kind of xed utility for fuel supply.
Denatured Ethanol* is safe to burn indoors without venting, because its main by-products are carbon dioxide,
water steam and heat.
In a house of typical construction, that is, one that is not of unusually tight construction due to heavy insulation
and tight seals against air inltration, an adequate supply of air for combustion and ventilation is provided through inltration. However, if the heater is used in a small room where less than (A) of air space is provided for each (B) per hour of heater rating (considering the maximum burner setting), the door(s) to adjacent room(s) should be kept open or a window to the outside should be opened at least (C) to guard against potential build up of indoor air pollution. Do not install or operate in a bathroom or any other small room.
Burner Kits (A)
Cubic Meter m
3
Cubic Feet [ft3]
(B)
BTU
(C)
Metric mm Imperial [in]
Minimum room size
Burner One
5.7
[200]
1000
25.4 [1]
The room cannot be less than 70m
3
[2472ft3] per burner.
Burner Two
5.7
[200]
1000
25.4 [1]
The room cannot be less than 25m
3
[1000ft3] per burner.
XL900 Burner
5.7
[200]
1000
25.4 [1]
The room cannot be less than 110m
3
[3884ft3] per burner.
XL700 Burner
5.7
[200]
1000
25.4 [1]
The room cannot be less than 100m
3
[3531ft3] per burner.
Around Burner
5.7
[200]
1000
25.4 [1]
The room cannot be less than 70m
3
[2472ft3] per burner.
Triple Burner
17.1
[604]
3000
76.2 [3]
The room cannot be less than 210m
3
[7416ft3].
Multiple Burners may be installed into a replace setting however the ventilation requirements must be
adhered to at all times.
13 © Copyright 2004 - 2011 The Fire Company Pty Ltd. All rights reserved. V7 0910.
Ventilation & EfciencyENGLISH
Efciency
The EcoSmart™ Fire is efcient because it is ueless which means all the heat stays in the room rather than most of it being ued outside as residual emissions.
You can turn the Burner on and off as desired. You can control the intensity of the ame through its
regulatory mechanism.
XL Burner: Not applicable.
These features allow you to control the amount of heat being generated and the quantity of Denatured
Ethanol* used.
Burner Kits Volume
Capacity
Thermal
Output Net
Heats
on Average
Fuel Consumption Burning Time
MAX setting
Burner One
5 Litres 1
1
⁄4 Gallons
14 Mj/h 13,000 BTU
3.5 Kw/h
Over 35m
2
OR 376.74ft
2
0.64 Ltr/hr OR 0.17 Gal/hr on MAX
0.49 Ltr/hr OR 0.13 Gal/hr on MED
0.28 Ltr/hr OR 0.074 Gal/hr on MIN
7 hours 25 minutes
Burner Two
2 Litres
1
⁄2 Gallon
10.09 Mj/h 9,570 BTU
2.8 Kw/h
Over 25m
2
OR 269ft
2
0.49 Ltr/hr OR 0.13 Gal/hr
3 hours 30 minutes
XL900 Burner
10 Litres 2
3
⁄5 Gallons
20.22 Mj/h 19,163 BTU
5.62 Kw/hr
Over 60m
2
OR 645ft
2
1 Ltr/hr OR 0.26 Gal/hr
When the XL Burner reaches 2 Litres OR 1⁄2 Gal of fuel, the ame becomes progressively smaller and burns for longer.
10 hours
XL700 Burner
8 Litres 2
1
⁄10 Gallons
15.69 Mj/h 14,869 BTU
4.36 Kw/hr
Over 50m
2
OR 538ft
2
0.77 Ltr/hr OR 0.2 Gal/hr
When the XL Burner reaches 2 Litres OR 1⁄2 Gal of fuel, the ame becomes progressively smaller and burns for longer.
9 hours
Around Burner
5 Litres 1
1
⁄4 Gallons
13.35 Mj/h 12,650 BTU
3.71 Kw/h
Over 50m
2
OR 538.2ft
2
When used indoors.
0.66 Ltr/hr OR 0.17 Gal/hr 7 hours
Triple Burner
3 x 5 Litres 3 x 11⁄4 Gallons
42 Mj/h 39,000 BTU
2.87 Kw/h
Over 105m
2
OR 1130.22ft
2
0.64 Ltr/hr OR 0.17 Gal/hr on MAX per burner
0.49 Ltr/hr OR 0.13 Gal/hr on MED per burner
0.28 Ltr/hr OR 0.074 Gal/hr on MIN per burner
7 hours 25 minutes
These values are indicative only and may vary depending on the model purchased, installation and denatured ethanol used.
Fuel Type
The EcoSmart™ Fire Burners are fuelled by a renewable energy source called Denatured Ethanol.
Some fuels are better than others, it’s important to source information on the best fuel in your area from your local retailer/distributor. Visit www.ecosmartre.com to nd out what Denatured Ethanol is called around the world.
Thermal Efciency
All EcoSmart™ Fire Burners have a Thermal Efciency of over 90%.
Loading...
+ 33 hidden pages