q Read all steps and guides carefully before installing and using your premium main faucet water
filtration system. Follow all steps exactly to correctly install. Reading this manual will also help you to
get all the benefits from the filtration system.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate
q
disinfection before or after the system. This system is certified for cyst reduction and may be used on
disinfected waters that may contain filterable cysts.
q All plumbing should be done in accordance with local codes and requirements. In Massachusetts,
plumbing code 248 CMR 3.00 and 10.00 shall be adhered to. Consult with your licensed plumber.
q The premium main faucet water filtration system works on water pressures of 30 psi (minimum) to
100 psi (maximum). If your house water pressure is over the maximum, install a pressure reducing
valve in the water supply pipe to the filtration system.
q Do not install the filtration system outside, or in extreme hot or cold temperatures. Temperature of
the water supply to the filtration system must be between 40°F and 100°F. Do not install on hot water.
Specifications & Dimensions
Supply Water Pressure Min. - Max.30 - 100 psi (207 - 689 kPa)
Supply Water Temperature Min. - Max.40 - 100 °F (4 - 38 °C)
Rated Service Flow1.85 gallons per minute (7.0 liters per minute)
Inlet - Outlet3/8" quick connect fittings and tubing included
1”
14-1/2”
Questions? Call Toll Free 1-800-693-1138 or visit www.ecopure.com
When you call, please be prepared to provide the model number and date code, found inside the top cover.
4”
3-1/2”
3
FIG. 1
1"
Parts & Tools
Included:
ilter head / bracket
= F
= Top cover
= Filter cartridge
= Tubing
= Bag containing installation parts and mounting screws
Not Included:
= Slotted and Phillips screwdrivers
= Pliers and adjustable jaw wrench
= Tubing cutter
= Electric drill
= Thread sealing tape
Typical Undersink Installation
Locate the water filter housing on the cold water supply pipe, under the sink, to filter the cold water.
Refer to the following drawing.
filtered water
HOTCOLD
shutoff valve
faucet
SINK
INLET
water supply
OUTLET
1”
3/8” tubing
from cold
INLET
yellow collar on
push-in fitting
mounting
screws (2)
3/8” tubing
to faucet
OUTLET
blue collar on
push-in fitting
NOTE: Be sure to allow a minimum space of 1-1/2” under
the system for removing the filter cartridge to change it.
4
FIG. 2
Loading...
+ 7 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.