Eco Pure EPHS, EP31, EP42 Installation And Operation Manual

Model EPHS
How to install, operate
and maintain your
Water Softener
& Whole Home Filter
Do not return system to store
If you have any questions or concerns when
installing, operating or maintaining your water
softener, call our toll free number:
1-800-693-1138
or visit www.ecopure.com
When you call, please be prepared to provide
the model and serial number of your product,
found on the rating decal, located on the rim
below the salt lid hinges.
of chlorine taste and odor, and Standard 44
for hardness reduction, efficiency and the
reduction of barium and radium 226/228, and certified to NSF/ANSI Standard 372.
Manufactured and warranted by
Ecodyne Water Systems
1890 Woodlane Drive Woodbury, MN 55125
Installation and Operation Manual
7361295 (Rev. B 6/14/17)
TABLE OF CONTENTS
Page
pecifications & Performance Claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
S
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Safety Guides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Inspect Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ater Conditioning Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
W
Installation Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
nstallation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12
I
Programming the Water Softener . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-14
Customizing Features / Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15-18
Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19-20
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21-23
Exploded View & Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-27
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Specifications & Performance Claims
This model is efficiency rated. The efficiency rating is valid only at the minimum salt dose. This system has a demand initiated regeneration (D.I.R.) feature that complies with specific performance specifications intended to min­imize the amount of regenerant brine and water used in their operation.
This water treatment system has a rated softener efficiency of not less than 3,350 grains of total hardness exchange per pound of salt (based on sodium chloride) and shall not deliver more salt than its listed rating or be operated at a sustained maximum service flow rate greater than its listed rating. This system has been proven to deliver soft water for at least ten continuous minutes at the rated service flow rate. The rated salt efficiency is measured by lab­oratory tests described in NSF/ANSI Standard 44. These tests represent the maximum possible efficiency that the system can achieve. Operational efficiency is the actual efficiency after the system has been installed. It is typically less than the rated efficiency, due to individual application factors including water hardness, water usage, and other contaminants that reduce a softener's capacity.
While testing was performed under standard laboratory conditions, actual performance of the system may vary based on local water conditions. This system has been tested according to NSF/ANSI Standard 42 for the reduction of chlorine taste and odor. The concentration of the indicated substance in water entering the system was reduced to a concentra­tion less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standard 42.
continued on next page
2
Specifications & Performance Claims
SPECIFICATIONS
Model EPHS
Model Code EPHS
4,000 @ 2.9 lbs.
1
Rated Softening Capacity (Grains @ Salt Dose)
Rated Efficiency (Grains/Pound of Salt @ Minimum Salt Dose) 4,230 @ 2.9 lbs.
Water Used During Regeneration @ Minimum Salt Dose 3.7 gal. / 1,000 grains
Total Water Used Per Regeneration @ Maximum Salt Dose 58.6 gallons
Rated Service Flow Rate 8.0 gpm
Amount of High Capacity Ion Exchange Resin 0.98 cu. ft.
Pressure Drop at Rated Service Flow 8.4 psig
Water Supply Max. Hardness 100 gpg
Water Supply Max. Clear Water Iron 3 ppm*
Water Supply Pressure Limits (minimum / maximum) 20 - 125 psi (137.9 - 861.8 kPa)
Water Temperature Limits (minimum / maximum) 40 - 120 °F (5 - 49 °C)
Minimum Water Supply Flow Rate 3 gpm (11.4 lpm)
Maximum Drain Flow Rate 2.0 gpm (7.6 lpm)
0.50 ppm
0.75 ppm
Rated Capacity at Chlorine Concentration** of: 1.0 ppm
1.5 ppm
2.0 ppm
2,280,000 gal. (8,630,000 liters)§ 1,520,000 gal. (5,750,000 liters)§ 1,140,000 gal. (4,310,000 liters)§
29,800 @ 9.3 lbs.
35,600 @ 15.6 lbs.
760,000 gal. (2,870,000 liters)§ 570,000 gal. (2,150,000 liters)§
*Capacity to reduce clear water iron is substantiated by laboratory test data. State of Wisconsin
requires additional treatment if water supply contains clear water iron exceeding 5 ppm.
§ From independent laboratory test data.
This system conforms to NSF/ANSI Standards 42 & 44 for the specific performance claims as
verified and substantiated by test data.
Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration time
based on the amount needed.
PERFORMANCE CLAIMS
Contaminant Influent Challenge Level
Barium 10 ±10% mg/L 2.0 mg/L
Radium 226/228 25 pCi/L 5 pCi/L
Substance Influent Challenge Level Reduction Requirement
Chlorine 2.0 ±10% mg/L 50%
Maxiumum Allowable
Product Water Level
Questions? Call Toll Free 1-800-693-1138 or visit www.ecopure.com
When you call, please be prepared to provide the model and serial number,
found on the rating decal, typically located on the rim below the salt lid hinges.
3
47-3/4"
41-1/2"
I
N - OUT
16-1/2"
1
9-3/4"
4
0-1/4"
FRONT VIEW SIDE VIEW
O
UT IN
3
-3/8"
16-1/2”
-3/8”
3
OUT IN
Dimensions
9-3/4”
1
40-1/4”
N – OUT
I
41-1/2”
47-3/4”
FRONT VIEW SIDE VIEW
FIG. 1
Safety Guides
= The water softener requires a minimum water flow of 3 gallons per minute at the inlet. Maximum allowable inlet
water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve if necessary (Adding a pressure reducing valve may reduce the flow). If your home is equipped with a back flow preventer, an expansion tank must be installed in accordance with local codes and laws.
= The water softener works on 24V DC electrical power, supplied by a direct plug-in power supply (included). Be
sure to use the included power supply and plug it into a nominal 120V, 60 Hz household outlet that is in a dry location only, grounded and properly protected by an overcurrent device such as a circuit breaker or fuse.
= Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adequate dis-
infection upstream or downstream of the system.
European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of accord-
ing to Waste Electrical and Electronic Equipment (WEEE) requirements. This directive or similar laws are in place nationally and can vary from region to region. Please refer to your state and local laws for prop­er disposal of this equipment.
In the state of Massachusetts: The Commonwealth of Massachusetts plumbing code 248-CMR shall be adhered to. A licensed plumber shall be used for this installation.
In the state of California: You must turn the Salt Efficiency Feature setting to ON. This may initiate more frequent recharges. However, it will operate at 4,000 grains per pound of salt or higher. To turn on the Salt Efficiency Feature, follow the instructions in the “Salt Efficiency” section of this manual.
Do not return the water softener to store.
If you have any questions, or there are missing parts or damage, please call Toll Free 1-800-693-1138 or visit www.ecopure.com
When you call, please be prepared to provide the model and serial number, found on the rating decal, typically located on the rim below the salt lid hinges.
4
Inspect Shipment
The parts required to assemble and install the water softener are included with the unit. Thoroughly check the water softener for possible shipping damage and
arts loss. Also inspect and note any damage to the
p shipping carton.
Packing List
Bypass Valve
Cover Lock
(for shipping only)
Drain Hose
Rim Insert
(for shipping only)
Remove and discard (or recycle) all packing materials. To avoid loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use
hem.
t
Installation
Adaptors
Grommet
Hose Clamps
Adaptor Elbow
Clips
(including 1 spare)
FIG. 2
Water Conditioning Information
IRON
Iron in water can cause stains on clothing and plumb­ing fixtures. It can negatively affect the taste of food, drinking water, and other beverages. Iron in water is measured in parts per million (ppm). The total* ppm of iron, and type or types*, is determined by chemical analysis. Four different types of iron in water are:
= Ferrous (clear water) iron = Ferric (red water) iron = Bacterial and organically bound iron = Colloidal and inorganically bound iron (ferrous or
ferric)
Ferrous (clear water) iron is soluble and dissolves in water. This water softener will reduce moderate amounts of this type of iron (see specifications).** Ferrous (clear water) iron is usually detected by taking a sample of water in a clear bottle or glass. Immediately after taking, the sample is clear. As the water sample stands, it gradually clouds and turns slightly yellow or brown as air oxidizes the iron. This usually occurs in 15 to 30 minutes.
When using the softener to reduce Ferrous (clear water) iron, add 5 grains to the hardness setting for every 1 ppm of Ferrous (clear water) iron. See "Set Water Hardness Number" section.
Ferric (red water), and bacterial and organically bound irons are insoluble. This water softener will not remove ferric or bacterial iron. This iron is visible
immediately when drawn from a faucet because it has oxidized before reaching the home. It appears as small cloudy yellow, orange, or reddish suspended particles. After the water stands for a period of time, the particles settle to the bottom of the container. Generally these irons are removed from water by filtra­tion. Chlorination is also recommended for bacterial iron.
Colloidal and inorganically bound iron is of ferric or fer­rous form that will not filter or exchange out of water. This water softener will not remove colloidal iron. In some instances, treatment may improve colloidal iron water. Colloidal iron water usually has a yellow appearance when drawn. After standing for several hours, the color persists and the iron does not settle, but remains suspended in the water.
SEDIMENT
Sediment is fine, foreign material particles suspended in water. This water softener will not remove sedi­ment. This material is most often clay or silt. Extreme amounts of sediment may give the water a cloudy appearance. A sediment filter installed upstream of the water softener normally corrects this situation.
* Water may contain one or more of the four types of
iron and any combination of these. Total iron is the sum of the contents.
** Capacity to reduce clear water iron is substantiated
by WQA test data.
5
Installation Requirements
LOCATION REQUIREMENTS
Consider all of the following when selecting an installa­tion location for the water softener.
Do not locate the water softener where freezing
=
temperatures occur. Do not attempt to treat water over 120ºF. Freezing temperatures or hot water damage voids the warranty.
= To condition all water in the home, install the water
softener close to the water supply inlet, and upstream of all other plumbing connections, except outside water pipes. Outside faucets should remain on hard water to avoid wasting conditioned water and salt.
= A nearby drain is needed to carry away regenera-
tion discharge (drain) water. Use a floor drain, laundry tub, sump, standpipe, or other options (check your local codes). See "Air Gap Requirements" and "Valve Drain Requirements" sections.
= The water softener works on 24V DC electrical
power, supplied by a direct plug-in power supply (included). Provide nearby a 120V, 60 Hz electrical outlet in accordance with NEC and local codes.
= Always install the water softener between the water
inlet and water heater. Any other installed water conditioning equipment should be installed between the water inlet and water softener (See Figure 4 below).
= Avoid installing in direct sunlight. Excessive sun
heat may cause distortion or other damage to non­metallic parts.
PLUMBING CODES
All plumbing must be completed in accordance with national, state and local plumbing codes.
In the state of Massachusetts: The Commonwealth of Massachusetts plumbing code 248-CMR shall be adhered to. A licensed plumber shall be used for this installation.
AIR GAP REQUIREMENTS
A drain is needed for regeneration water (See Figure
3). A floor drain, close to the water softener, is pre­ferred. A laundry tub, standpipe, etc. are other drain options. Secure valve drain hose in place. Leave an air gap of 1-1/2” between the end of the hose and the drain. This gap is needed to prevent backflow of sewer water into the water softener. Do not put the end of the drain hose into the drain.
1-1/2”
air gap
FLOOR DRAIN
Drain Hose
1-1/2”
air gap
Drain Hose
1-1/2”
air gap
LAUNDRY TUBSTANDPIPE
Drain Hose
FIG. 3
THE PROPER ORDER TO INSTALL WATER TREATMENT EQUIPMENT
Untreated Water to
Cold Water
to House
Hot Water
to House
Outside Faucets
Water
Heater
Softener
Water
Optional
Sediment
Filter
City Water Supply
Pressure
Tank
Well Water Supply
OR
Well
Pump
FIG. 4
6
Installation Requirements
VALVE DRAIN REQUIREMENTS
Using the flexible drain hose (included), measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible drain hose, a rigid valve drain run must be used. Purchase a com­pression fitting (1/4 NPT x 1/2 in. minimum tube) and 1/2" tubing from your local hardware store. Plumb a rigid drain as needed (See Figure 6).
NOTE: Avoid drain hose runs longer than 30 feet.
Avoid elevating the hose more than 8 feet above the floor. Make the valve drain line as short and direct as possible.
1/4” NPT
Thread
Clip
Cut barbs from drain fit-
ting (pull clip to remove
1/4 NPT Threads
Barbs
fitting from valve)
Barbs for 3/8” I.D. Tubing
Hose Clamp
Drain Hose
FIG. 5
Compression Fitting.
1/4 NPT x 1/2” O.D.
Tube (not included)
1/2” Outside Dia.
Copper Tube
(not included)
FIG. 6
INLET / OUTLET PLUMBING OPTIONS
Always install either a single bypass valve (provided), as shown in Figure 7, or, if desired, parts for a 3 valve bypass system (not included) can be purchased and assembled, as shown in Figure 8. Bypass valves allow you to turn off water to the softener for mainte­nance if needed, but still have water in house pipes.
Pipe fittings must be 3/4” minimum.
Use:
= Copper pipe = Threaded pipe = PEX (Crosslinked Polyethylene) pipe = CPVC plastic pipe = Other pipe approved for use with potable water
IMPORTANT: Do not solder with plumbing attached to
installation adaptors and single bypass valve. Soldering heat will damage the adaptors and valve.
Outlet
Valve
SINGLE BYPASS VALVE
Pull out for “Service” (Soft water)
Push in for “Bypass”
3 VALVE BYPASS
Bypass
Valve
From Water
Softener
To Water
Softener
FIG. 7
Inlet Valve
FIG. 8
7
ard Water
H
Controller
Plug-in Power Supply
Salt Storage Tank
Overflow Hose*
To
Grommet
Valve
rain
D
o Outside
T
Faucets
H
lamp
C
Drain
lbow
E
ose
H
Clamp
Installation Instructions
TYPICAL INSTALLATION
e
p
ose
i
P
r
e
t
a
W
n
i
a
M
ater Softener
W Valve
Valve Drain Hose*
Secure Valve Drain Hose in place over Floor Drain
Conditioned Water
Clips
Inlet
Lubricated
O-ring
Outlet
Pipe
1” NPT Sweat Adaptor (not included)
1” NPT Threaded Adaptor
O-ring
Single Bypass Valve
*Do not connect the
water softener valve drain hose to the salt storage tank overflow hose.
TURN OFF WATER SUPPLY
1. Close the main water supply valve, located near the
well pump or water meter.
2. Shut off the electric or fuel supply to the water heater.
3. Open all faucets to drain all water from house pipes.
NOTE: Be sure not to drain water from the water
heater, as damage to the water heater ele­ments could result.
ASSEMBLY
1. EcoPure models are factory assembled. During
installation, unsnap and remove the top cover, together with the salt lid, to expose the softener valve assembly. Set them aside to prevent damage. Check the brinewell to be sure it is secured and ver­tical (See Figure 11).
2. Install the brine tank overflow grommet and elbow into the 13/16” diameter hole in the back of the salt storage tank wall.
Floor Drain
MOVE THE UNIT INTO PLACE
1. Move the water softener into the desired location.
IMPORTANT: Do not place shims directly under the salt
2. Visually check and remove any debris from the water
3. Make sure the turbine assembly spins freely in the
4. If not already done, put a light coating of silicone
5. Push the single bypass valve into the softener valve
IMPORTANT: Be sure the clips snap firmly into place so
1-1/2” air gap
NOTE: See “Air Gap Requirements” section.
NOTE: Water Softener shown with Salt Lid
and Top Cover removed
FIG. 9
Set it on a solid, level surface.
storage tank to level the softener. The weight of the tank, when full of water and salt, may cause the tank to fracture at the shim.
softener valve inlet and outlet ports.
"out" port of the valve (See Figure 10).
grease on the single bypass valve o-rings.
as far as it will go. Snap the two large holding clips into place, from the top down as shown in Figures 12 & 13.
the single bypass valve will not pull out.
8
Installation Instructions
COMPLETE INLET AND OUTLET PLUMBING
Measure, cut, and loosely assemble pipe and fittings from the main water pipe to the inlet and outlet ports of
he water softener valve. Be sure to keep fittings fully
t together, and pipes squared and straight.
Be sure hard water supply pipe goes to the water sof­tener valve inlet side.
NOTE: Inlet and outlet are marked on the water sof-
tener valve. Trace the water flow direction to be sure hard water is to inlet.
IMPORTANT: Be sure to fit, align and support all
plumbing to prevent putting stress on the water softener valve inlet and outlet. Undue stress from misaligned or unsup­ported plumbing may cause damage to the valve.
Complete the inlet and outlet plumbing for the type of pipes you will be using.
Turbine
Turbine Support Assembly
alt Lid
S
Brinewell
Cover
Brinewell
Stand
Tube
Float Stem
Brine Valve
Top Cover
Nozzle & Venturi
Assembly
Brine Tank
verflow
O
Grommet
Brine Tank
Overflow
Elbow
13/16” Hole
Brine Tubing
Salt Storage Tank
FIG. 11
Valve Outlet
FIG. 10
Correct Assembly
Clip
Outside diameter
of water softener
valve inlet & outlet
Clip
Channel
Outside diameter of clip channel on single bypass valve
Single Bypass Valve
FIG. 12
FIG. 13
NOTE: Be sure all 3 tabs of the clip go through the matching
holes on the water softener valve inlet or outlet, and fully into the channel on the single bypass valve. Make sure that the tabs are fully seated.
9
Loading...
+ 19 hidden pages