
INSTALLATION INSTRUCTIONS
LED E-DD SERIES
CAUTIONS
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety
precautions should always be followed including the
following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1. DANGER- Risk of shock- Disconnect power before
installation.
DANGER – Risque de choc – Couper l’alimentation
avant l’installation.
2. SUITABLE FOR WET LOCATIONS.
CONVIENT AUX EMPLACEMENTS MOUILLES.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
FIGURE 1
Document: Date
Created By: ECO#
1. Install xture cover plate to conduit using either knockout.
2. Use xture to mark the location for the lag bolts on
mounting surface.
3. Install two lower lag bolts into mounting surface, allowing
the head of each bolt to remain 1/4” (6.4 mm) from
mounting surface.
4. Wire black xture lead to the incoming hot lead and the
white xture lead to the incoming neutral (Common) lead.
Attach bare copper or green ground xture lead to the
incoming ground lead.
5. Slide xture onto two lag bolts from Step 3 and install third
lag bolt in top slot of xture. Secure all lag bolts.
6. Secure cover plate with (2) machine screws, washers and
nuts.
7. Install the photo-control by aligning the arrow on the top
of the photo-control with the arrow on the photo-control
socket and inserting pins into the socket. Twist photocontrol clockwise until the arrow on the photocontrol is
pointing north. (Photocontrol must be rotated at least 1/8
turn to properly lock in place).
NOTE: Improper installation of the photo-control may result
in damage to the photo-control.
LPN00532X0001A0_A
TMT 008325
2017-9-26
E-DD SERIES-
DIRECT MOUNTED
DIRECT MOUNTING
FIGURE 2- Direct Mounting Components
FIGURE 3- Photo-control Installation
www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409

INSTALLATION INSTRUCTIONS
LED E-DD SERIES
FIGURE 4
E-DD SERIES-
ARM MOUNTED
ARM MOUNTING
E-DD0 Series- Require use of E-ACADD1 Kit
E-DD1 Series- Necessary arm mounting
components included with fixture
Document: Date
Created By: ECO#
FIGURE 6- Photo-control Installation
LPN00532X0001A0_A
TMT 008325
2017-9-26
FIGURE 5: Arm Mounting Components
1. Loosely install (2) carriage bolts with lock washers and nuts
into wall mount bracket.
2. Install wall mounting bracket to mounting surface with (4)
Lag bolts a provided.
3. Insert short end of arm into mounting bracket. Adjust to
desired direction and tighten carriage bolts.
4. Feed (Customer Supplied) Ground wire up through arm.
5. Feed black and white xture wires down through arm.
6. Using (2) Hex bolts and arm bracket, secure housing to
arm.
NOTE: When installing the housing on to the arm, allow
1/4” (6.4 mm) spacing between end of arm and the housing
to prevent ground wire from being pinched.
7. Install (1) green ground screw onto arm bracket at location
marked “GND” and tighten ground screw to ground wire.
8. Wire black xture lead to the incoming hot lead and the
white xture lead to the incoming neutral (Common) lead.
9. Install the photo-control by aligning the arrow on the top
of the photo-control with the arrow on the photo-control
socket and inserting pins into the socket. Twist photocontrol clockwise until the arrow on the photocontrol is
pointing north. (Photocontrol must be rotated at least 1/8
turn to properly lock in place).
NOTE: Improper installation of the photo-control may result
in damage to the photo-control.
FCC NOTICE
CAUTION: Changes or modications not expressly approved could
void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area
is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
CAN ICES-005 (A)/NMB-005 (A)
www.e-conolight.com | 888.243.9445 | FAX: 262.504.5409