Econ 1515, 1514, 1516 Installation & Operation Manual

Installation & Operation Manual
Proven Quality since 1892
Content
1. ERIKS operating companies
3. Requirements for maintenance staff
4. Transport and storage
5. Function
6. Application
7. Installation
8. Maintenance
9. Service and repair
10. Assembly
11. Possible danger
12. Troubleshooting
13. Removal
1. ERIKS operating companies
ECON safety relief valves are being delivered by several ERIKS operating companies on a worldwide basis. In this manual these will be referred to as ‘ERIKS’, the individual terms of delivery of the ERIKS operating company having executed the order are applicable.
2. Product description
The ECON safety relief valves have very precise fabricated sealing surfaces and conductivity, to guaranty a good function. For this reason, safety relief valves have to be handled very careful. The marking makes the identification of the valve easier and contains:
- size
- set pressure
- maximum temperature Tmax
- heat number
- ECON logo + figure number
- year of fabrication
- CE marking and identification number of the inspection authority
3. Requirements for maintenance staff
The staff assigned to assembly, operating and maintenance tasks should be qualified to carry out such jobs and in any circumstance, ensure personal safety
4. Transport and storage
Transport and storage should always be carried out with the disc complete closed and the safety relief valve should be protected against external forces, influence and destruction. The safety relief valve should be stored in an unpolluted space and should also be protected against all atmospheric circumstances. There should be taken care of the temperature and humidity in the room, in order to prevent condensate formation.
5. Function
ECON safety relief valves have as function to protect the system against excessive pressure. At a safety relief valve, the following pressures can occur:
- Working pressure, the pressure in the system
- set pressure, the adjusted pressure at which the safety relief valve under normal use circumstances is opening. The forces on the disc are in balance.
- colt test pressure, the adjusted static inlet pressure, at which the safety relief valve on the test bench starts to open.
- back pressure, the sum of pressure built up in the vent line when relief and the pressure in the vent line when this is part of a system with a higher pressure than the ambient pressure.
Measured pressures are barg pressures.
ECON safety relief valves Fig. 1514, 1515 and 1516 www.eriks.com Rev. 4
Installation & Operation Manual
Fig.1514
Fig.1515
Fig.1516
Max./min. allowable Pressure P (bar)
20/0
42/0
130/0
200/0
Max./min. allowable Temperature T (°C)
160/0
200/0
200/0
20/0
Proven Quality since 1892
For a correct working of the safety relief valve, the outlet of the system may certainly not give any back pressure (OPEN outlet).
Rules for the pressure relief valves under pressure.
6. Application
ECON safety relief valves with threaded connection are mainly applied in the process industry as a relief valve for thermal expansion. Suitable for gasses and liquids. This type of safety valve is also suitable as an overflow for the use of extreme conditions e.g. aggressive or abrasive media, it is recommended to mention this at the ordering stage, to verify whether the valve is suitable. The installation designer is responsible for the safety relief valve selection, suitable for the working conditions. The valves are unsuitable, without written permission of an ERIKS company, to apply for hazardous media as referred into Regulation (EC) No 1272/2008.
7. Installation
During the assembly of the ECON safety relief valves, the following rules should be observed:
- make sure before an assembly that the safety relief valves were not damaged during the transport or storage.
- make sure that the applied safety relief valves are suitable for the working conditions, medium used in the plant and the right system connections, according to pressure and temperature limits as per the tag plate.
- before plant startup, especially after repairs carried out, flash out the pipeline, before installing the safety relief valves.
- de safety relief valves should always be mounted side up, as mentioned by the vertical flow direction (pressure under the disc).
- the body part which contains the spring and the adjustable bolt, may not be isolated, because otherwise the spring gets to warm.
- the interior of the safety relief valve and pipeline must be free from foreign particles.
- the vent line should be for liquids mounted sloped. For gasses and damps the vent line should be mounted slightly rising.
- the relief opening must be so located, that there cannot be any danger, because of the blow-off pressure.
- install pipelines so that damaging transverse, excessive vibrations, bending and tensional forces are avoided.
- the joints on the pipeline must not cause additional stress resulted from excessive tightening, user shall select proper gaskets according the working temperature, working pressure and medium.
- the safety relief valves can’t be operated, because they are working on the overpressure of the medium.
8. Maintenance
Before starting any service jobs, make sure that the medium supply to the pipeline is cut off, pressure was decreased to ambient pressure, the pipeline is completely cleaned and ventilated and the plant is cooled down. Always keep safety instructions in mind and take all personal safety precautions.
During maintenance, the following rules should be observed:
- always keep personal safety precautions in mind and always use appropriate protection e.g. clothing, masks, gloves etc.
- be alert that the temperature still can be very high or low and can cause burns.
- check the safety relief valve on all possible leaking possibilities.
ECON safety relief valves Fig. 1514, 1515 and 1516 www.eriks.com Rev. 4