Ecolink Z-Wave Plus Flood/Freeze Installation Instructions Manual

© 2018 Ecolink Intelligent Technology Inc. PN: H214104 RevA
Z-Wave Plus Flood/Freeze Sensor Installation Instructions
Product Overview
Z-Wave Plus enabled device which detects flood and freeze. Reports tamper condition when cover is open
Product Specifications
Network Inclusion
The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network both the sensor and the network controller must be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the controller’s inclusion mode.
1) Verify that the Z-Wave Plus controller you are using is compatible with the Flood Freeze sensor.
2) Either mount or move the Flood Freeze sensor as close as possible to the location the sensor will remain. See installation section below.
3) Put your Z-Wave Plus Controller into add (inclusion) mode.
4) To add the sensor to an existing Z-Wave network, follow the directions to put your Z-Wave Controller into add (inclusion) mode. The Flood Freeze enters add
and remove (inclusion/exclusion) when powered on (when battery is added). If the LED starts blinking continuously, the sensor has no node ID and was not successfully added, so start step C over again. Make sure to remove the battery for 10 seconds if adding to a Z-Wave network fails.
5) If after 5 seconds the LED is not blinking, look on the Z-Wave controller’s interface for feedback on whether the sensor was added successfully. If you do not
see any feedback that the sensor was added, follow directions for removing the sensor from a Z-Wave network, and then try adding the sensor again. If you are still having problems, you may need to add additional Z-Wave listening devices in-between the controller and the sensor.
Network Exclusion
1) Any sensor can be removed from any Z-Wave Plus controller. Follow the directions to put your Z-Wave Plus Controller into exclusion mode. Please use this
procedure only when the network primary controller is missing or otherwise inoperable.
2) Open the Flood Freeze case and remove the battery for 1 seconds. Replace the battery and the controller should remove the device from the Z-Wave
network.
Network Inclusion/Exclusion: Key Points to Remember
Controller inclusion/exclusion mode must be activated BEFORE starting sensor inclusion or exclusion mode. The sensor can only be included into one controller network at a time, and must be excluded from one network before inclusion in another. The plastic pull tab must be removed to enable sensor operation. The sensor automatically enters inclusion mode at power-up. Exclusion mode on the senor is initiated following the same exact procedure as inclusion.
© 2018 Ecolink Intelligent Technology Inc. PN: H214104 RevA
LED Status
The Flood Freeze is equipped with a single LED. The state of the LED will change based on the state of the device.
Device not included = Light breathing (slow blink) Flood Detected = Single LED blink Freeze Detected = Single LED blink Case Opened = LED will remain on while case open
Factory Default
The Flood Freeze sensor factory defaults on network exclusion. Please use this procedure only when the network primary controller is missing or otherwise
inoperable.
Testing
To test the RF transmission from the mounted position you can generate a tamper by removing the cover. This will send a signal to the control panel. To test flood/water detection, place the probe in a cup of water. Placing the sensor in a freezer to test freezing may not work if the signal cannot penetrate the appliance. You may place a bag of ice over the sensor to test freeze detection. (may take upwards of 30 minutes to detect)
Replacing the Battery
When the battery is low a low battery notification will be sent to the life line nodes. To replace the battery:
1. Remove the top cover to reveal the battery. This will send a tamper signal to the lifeline nodes.
2. Replace with a Panasonic CR123A battery ensuring the + side of the battery faces as indicated on the device.
3. Re-attach the cover, you should hear a click when the cover engages properly.
Installation
The package contains the following:
1- Flood Sensor with Probe 1- Sensor Mounting Bracket 2- Screws for Sensor Mounting Bracket 1- Adhesive tape for Sensor Mounting Bracket 2- Screws for probe 1- Adhesive tape for mounting Probe.
© 2018 Ecolink Intelligent Technology Inc. PN: H214104 RevA
STEP ONE Identify Location for Sensor:
Determine where to place the probe sensor. The probe should be located where water is most likley to pool if a leak occurs.
The sensor needs to be mounted while the probe can reach the location described above.
STEP TWO Mount the Sensor:
Mount the sensor to a clean dry surface with the adheasive tape and/or the screws provided
Adhesive
Tape
Mounting
Bracket
Screws
(optional)
Sensor
© 2018 Ecolink Intelligent Technology Inc. PN: H214104 RevA
STEP THREE Mount the Probe:
Mount the probe to a clean dry surface where water is most likley to pool if a leak occurs.
ADDITIONAL NOTES AND SUMMARY:
The sensor can slide onto the mounting bracket in two different ways. To ensure that the sensor is securely fastened it is recommended that the tab on the
bracket engage the back of the sensor.
Before attaching the bracket to a surface note how the bracket will need to be oriented in order for the tab to engage the sensor. The required orientation
of the sensor determines the bracket orientation.
The sensor slides onto the bracket until the tab engages. Please be advised that adhesive tape may damage the surfaces to which it is attached.
© 2018 Ecolink Intelligent Technology Inc. PN: H214104 RevA
Z-Wave Plus Specific Information
Z-Wave Plus is a wireless mesh network and data protocol that allows devices from many different manufacturers to interoperate. This device implements Z-Wave Plus functionality, Network Wide Inclusion, and Explorer frames. This device is asleep most of the time but can respond to queries on a Wake Up Notification; however for test purposes, the device will stay awake while tampered for testing Z-Wave Plus command class functionality. The following information is intended for software engineers working on Z-Wave Plus controllers and home automation enthusiasts to integrate the Z-Wave Plus sensor into their system.
Device Classes
Generic Device Class
GENERIC_TYPE_SENSOR_NOTIFICATION
Specific Device Class
SPECIFIC_TYPE_NOTIFICATION_SENSOR
Command Classes
COMMAND_CLASS_ZWAVEPLUS_INFO
v2
COMMAND_CLASS_VERSION
v2
COMMAND_CLASS_MANUFACTURER_SPECIFIC
v2
COMMAND_CLASS_DEVICE_RESET_LOCALLY
v1
COMMAND_CLASS_POWERLEVEL
v1
COMMAND_CLASS_BATTERY
v1
COMMAND_CLASS_NOTIFICATION_V5
v5
COMMAND_CLASS_SENSOR_BINARY_V2
V2
COMMAND_CLASS_ASSOCIATION
v2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
v1
COMMAND_CLASS_WAKE_UP
v2
Manufacturer ID
MFG_ID_ECOLINK ( 0x014A )
Product Type
0x05
Product ID
0x0F
© 2018 Ecolink Intelligent Technology Inc. PN H214104 Rev - A
Z-Wave Plus Command Class Notification
These notifications are sent unsolicited to the lifeline Association group.
Notification Type Event
Cause
Water (0x05)
Water Detected (0x02)
Probe submerged in water
Water No longer Detected (0x04)
Probe no longer submerged in water
Home Security (0x07)
Tampering, Product Cover Removed (0x03)
Case Tampered
Event Inactive (0x00)
Case Restored to Closed Position
Power Management (0x08)
Replace Battery Soon (0x0A)
Battery is Getting Low
Replace Battery Now (0x0B)
Battery Needs Replacing
Z-Wave Plus Command Class Sensor Binary
© 2018 Ecolink Intelligent Technology Inc. PN H214104 Rev - A
These notifications are sent unsolicited to the lifeline Association group.
Notification Type
Event
Cause
Water (0x06)
Water Detected (0xFF)
Probe submerged in water
Water No longer Detected (0x00)
Probe no longer submerged in water
Freeze (0x07)
Freezing Temperature Detected (0xFF)
Temperature nearing Freeze Point
Freeze no longer detected (0x00)
Temperature no longer near Freezing
Z-Wave Plus Command Class Association
The Flood Freeze sensor supports one association group with up to 5 nodes. All notifications, and events are sent to association group one (lifeline).
© 2018 Ecolink Intelligent Technology Inc. PN H214104 Rev - A
Association
This sensor has one Association groups of 5 nodes. Group one is a lifeline group who will receive unsolicited messages relating to flood/freeze notifications, case tampering notifications, low-battery notifications.
Network Wide Inclusion
This sensor also supports Network Wide Inclusion such that the Sensor can be included into the Z-Wave network over the mesh network and not directly near the main controller. This mode is automatically activated after regular inclusion was not successful
Wake-Up Notification
The sensor will wake up every so often and when the case is closed to send a Wake-Up Notification to allow the life line master node controller that the sensor is now available for any queued messages that the controller may have for the sensor. The time between Wake-Up Notifications can be configured with the Wake­Up Notification command class to be between 1 hour and 1 week with interval steps of 200 seconds. The sensor will also send a wakeup notification whenever the case is closed.
ENGLISH
GUARANTEE TERMS AND CONDITIONS
© 2018 Ecolink Intelligent Technology Inc. PN H214104 Rev - A
UNIVERSAL ELECTRONICS / ECOLINK warrants to the original purchaser that this product will be free from defects in materials and workmanship under normal and correct use for a period of 2-year from the date of original purchase. This product will be repaired or if necessary replaced free of charge if it has been proven to be defective within the 2-year warranty period. The forwarding costs are on the account of the owner; the costs of returning the product are on the account of UNIVERSAL ELECTRONICS / ECOLINK.
This warranty does not cover damage or failures caused by products or services not supplied by UNIVERSAL ELECTRONICS / ECOLINK, or which result from not mounting the product according to manual instructions. This also applies when the product has been modified / repaired by others than UNIVERSAL ELECTRONICS / ECOLINK or if a fault is the result from accident, misuse, abuse, neglect, mishandling, misapplication, faulty installation, improper maintenance, alteration, modifications, fire, water, lightning, natural disasters, wrong use or carelessness.
To obtain warranty service during the warranty period, please notice that we need your original purchase receipt so that we may establish your eligibility for service. If you have bought this product for purposes which are not related to your trade, business or profession, please remind that you may have legal rights under your national legislation governing the sale of consumer goods. This guarantee does not affect those rights.
• Please ensure a minimum distance of 5 cm around the apparatus for sufficient ventilation.
• Please ensure that the ventilation is not impeded by covering the product with items such as newspapers, tablecloths, curtains, etc.
• Do not place near naked flame sources, such as lighted candles.
• To reduce the risk of fire or electric shocks do not expose this apparatus to rain or moisture, dripping or splashing.
• Use the apparatus only in moderate climates (not in tropical climates).
© 2018 Ecolink Intelligent Technology Inc. PN H214104 Rev - A
CAUTION NOTICE
CAUTION RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. ONLY USE THE SUPPLIED BATTERIES OR MAKE SURE THEY ARE 100% COMPATIBLE. DISPOSE OF USED BATTERIES OBSERVING ENVIRONMENTAL PROTECTION RULES.
DECLARATION OF CONFORMITY
Hereby, Universal Electronics BV declares that the radio equipment type XXXXXXX is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: xxxxxxxxxxxxxxxx
RECYCLING / WEEE DIRECTIVE
This product bears the selective sorting symbol for waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19 / EU in order to be recycled or dismantled to minimize its impact on the environment. User has the choice to give this product to a competent recycling organization or to the retailer when user buys a new electrical or electronic equipment.
Z-WAVE CERTIFICATION
This product is Z-Wave certified. The Z-Wave Certification # is ZCXX-XXXXXXX. For more information, please visit www.z-wave.com
This product is covered by one or more claims of patents found at: http://sipcollc.com/patent-list
Loading...