© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
Motion Sensor with Pet Immunity Installation Instructions
Product Overview
Z-Wave PlusTM enabled device which transmits upon detection of movement
Configurable to be less sensitive to the movement of small and medium size household pets
Reports tamper condition if cover is removed
Product Specifications
For indoor use only
Operating frequency: 908.42 MHz
Operating range: Up to 100 feet (30.5 meters) line-of-sight
Operating temperature: 0˚C to 49˚C, 32˚F to 120˚F (ambient temperature)
Detection radius: Maximum 45 feet (see detection region diagram)
Detection angle: 45 degrees in either direction from the sensor’s center (see detection region diagram)
Battery type: 3V Lithium CR123A
Battery life: approximately 3 years
Passive Infrared (PIR) based technology
Network Inclusion
The sensor must be added to a Z-Wave network prior to use. To include the sensor in a network, both the sensor and the network controller must
be in inclusion mode at the same time. Refer to the instructions provided by the manufacturer of your specific controller for details on initiating the
controller’s inclusion mode.
STEP ONE Start by placing the controller into inclusion mode.
STEP TWO Activate inclusion mode for the sensor by removing the battery isolation pull tab, or by inserting the battery (see next
section for battery installation tips). When the inclusion process is complete the red LED will turn on for approximately 10
seconds and then it will go out. If the LED continues to flash repeat the inclusion process.

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
STEP THREE Test the motion sensor before mounting it. Place the sensor in an unoccupied room. Leave the room for at least 4
minutes. Return to the room and pass in front of the sensor lens. The LED will flash once to indicate that motion was
detected.
Notes:
Sensor inclusion mode can also be initiated by inserting a pin or paper clip into the small round hole on the back side of the sensor.
The sensor also features a test mode so that motion detection can be tested without waiting 4 minutes. For more information refer to the “Test Mode”
section of these instructions.
Network Inclusion: Key Points to Remember
Controller inclusion mode must be activated BEFORE starting sensor inclusion mode.
The sensor can only be included into one controller network at a time, and must be excluded from one network before inclusion in another.
Removing the pull tab connects the battery and initiates sensor inclusion mode. Inclusion mode can also be initiated by removing the battery for at least 5 seconds, reinstalling the battery,
then replacing the sensor cover.
The plastic pull tab must be removed to enable sensor operation.
The sensor automatically enters inclusion mode at power-up.
Exclusion mode on the senor is initiated following the same exact procedure as inclusion.
Battery Installation Tips

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
Installation
The package contains the following:
1x Sensor
1x Sensor mounting bracket
4x screws
2x jumper
1x battery
3x pieces of adhesive tape
STEP ONE Mount bracket to wall
First attach the sensor mounting bracket to the wall using either adhesive tape OR screws (optional). For best performance mount the bracket
6.5 to 7.5 feet above the floor (2 to 2.3 meters).
Corner Mount Flush Mount

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
Note: For best results, attach adhesive tape to bracket FIRST, then position on wall. Adhesive tape is VERY STRONG so moving the bracket after attaching will be difficult.
STEP TWO Attach Motion Detector to Bracket
ADDITIONAL NOTES AND SUMMARY:
BEFORE attaching the bracket to a surface note how the bracket will need to be oriented
in order for the tab to engage the sensor. The required orientation of the sensor determines
the bracket orientation. The large clip that holds the case together is located on the TOP.
Please be advised that adhesive tape may damage the surfaces to which it is attached and
then removed from.
The sensor slides onto the bracket until the tab engages and CLICKS.
The distribution pattern of the motion detector is approximately +/- 50 degrees left and right
of center and at maximum sensitivity will reach a maximum of approximately 45 feet. See
example distribution pattern below.
Once the mounting bracket is in place, align the holes on the back of
the motion detector with the key on the bracket. Slide the sensor
down on the keys until it snaps tight.
Motion Detector Distribution Pattern

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
Adjusting the Sensitivity of the Motion Sensor
The motion sensor has sensitivity adjustment via jumper placement on a pair of pins on
the circuit board of the sensor. Refer to the battery replacement section to open the
case and find the jumper pins inside the case.
Test Mode
The amount of time it takes for the sensor to reset after motion has been detected can be
shortened for quicker motion sensor testing. To enter test mode remove the cover from the
sensor. Find the pair of metal pins on the lower right hand side of the circuit board labeled
“TEST”. Connect these two pins together using the provided jumper. Replace the sensor
cover. After approximately ten seconds the red LED will go out. The sensor is now in test
mode. In test mode the LED will flash once when motion is detected and again when motion
detector is ready again. In this mode you can wave your hand in front of the sensor or walk
around the room and see where motion is detected. Note that there must be a length of
time without motion before motion detect is enabled again. To restore normal operation,
simply remove the test jumper and replace the sensor cover.

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
What is Z-Wave?
The Z-Wave protocol is an interoperable, wireless, RF-based communications technology designed specifically for control, monitoring and status reading
applications in residential and light commercial environments. Mature, proven and broadly deployed (with over 35 million products sold worldwide), Z-Wave is
by far the world market leader in wireless control, bringing affordable, reliable and easy-to-use 'smart' products to many millions of people in every aspect of
daily life. Certified Z-Wave devices regardless of manufacturer can work together to form a Z-Wave mesh network. Always on Z-Wave devices can act as
repeaters in the mesh increasing range and redundancy.
For a more complete look at Z-Wave technology for non-technologists, and to learn more about Z-Wave's role as a key enabling technology for the Internet of
Things and connected objects, please visit www.z-wave.com.
Z-Wave Device Class and Command Class Information
This Z-Wave sensor is a Z-Wave generic Device Class of GENERIC_TYPE_SENSOR_NOTIFICATION, and a specific device class of
SPECIFIC_TYPE_NOTIFICATION_SENSOR, and the supported command classes are COMMAND_CLASS_ZWAVEPLUS_INFO, COMMAND_CLASS_VERSION,
COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_POWERLEVEL, COMMAND_CLASS_BATTERY, COMMAND_CLASS_NOTIFICATION_V4,
COMMAND_CLASS_ASSOCIATION, COMMAND_CLASS_ASSOCIATION_GRP_INFO, COMMAND_CLASS_WAKE_UP, COMMAND_CLASS_SENSOR_BINARY,
COMMAND_CLASS_CONFIGURATION, COMMAND_CLASS_BASIC.
Manufacturer Specific
Manufacturer ID: 0x014A
Product Type: 4
Product ID: 1
Factory Default

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
To restore this sensor to factory default settings, follow the instructions in this manual to exclude this sensor from the Z-Wave network. Upon completion of
removal from the network the sensor will restore itself to factory default settings automatically. Use this procedure only in the event that the network primary
controller is missing or otherwise inoperable.
Keeping Awake for Testing and Configuration
To save power, this sensor sleeps most of the time and is therefore not awake to receive messages from a gateway for testing. Removing the top case from the
sensor will put in device into a tampered mode in which the sensor will stay awake and able to receive messages. Most of the time an end user would not do
this, but if the sensor needs to be configured after inclusion, an end user can follow the instructions below for sending Wake-Up notifications.
Association
This sensor has two Association groups of 5 nodes each. Group one is a lifeline group who will receive unsolicited messages relating to motion detection
notifications, case tampering notifications, low-battery notifications, and sensor binary reports. Group 2 is intended for devices that are to be controlled i.e.
turned on or off (on only by default) with a Basic Set. On inclusion the controller should put its node ID in group 1 but not group 2.
Network Wide Inclusion
This sensor also supports Network Wide Inclusion such that the Sensor can be included into the Z-Wave network over the mesh network and not directly near
the main controller. This mode is automatically activated after regular inclusion was not successful.
Motion Detection
Unknown Location(0x08)
1 Yes via Notification Set of notificationType
(0x07) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Sensor Binary Report of 0xFF
Yes via Configuration Command Class
Parameter Number: 2
Size: 1
A Configuration Value: 0xFF (On) / 0x00 (Off)
1 Yes via Notification Set of notificationType
(0x07) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Sensor Binary Report of 0x00
1 Yes via Configuration Command Class

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
A Configuration Value: 0xFF (On) / 0x00 (Off)
By factory default this feature is disabled and must
be enabled via Configuration Command Class.
2 Yes via Configuration Command Class
Parameter Number: 1
Size: 1
A Configuration Value: 0xFF (On) / 0x00 (Off)
Parameter Number: 2
Notification Report of Home Security (0x07),
Tampering product cover removed (0x03)
Yes via Notification Set of notificationType
(0x07) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Up Notification Command Class
Notification Report of Power Management (0x08),
Replace battery now (0x0B)
Yes via Notification Set of notificationType
(0x08) and status of 0x00: This type of
notification turned off
0xFF: This type of notification turned on
Wake-Up Notification
The sensor will wake up every so often and when the case is closed to send a Wake-Up Notification to allow the life line master node controller that the sensor is
now available for any queued messages that the controller may have for the sensor. The time between Wake-Up Notifications can be configured with the WakeUp Notification command class to be between 1 hour and 1 week with interval steps of 200 seconds.
Configuration
The sensor has two configuration parameters. Parameter 1 configures the sensor to send or not send Basic Set commands of 0x00 to nodes in Association group
2 turning the devices off when the sensor is in a restored state (i.e. motion not detected). By default the sensor does NOT send Basic Set commands of 0x00.
Parameter 2 configures the sensor to either to send or not to send Sensor Binary Report commands to Association Group 1 when the sensor is faulted and
restored. If the controller is fully compatible with the Notification Command Class thereby making the Sensor Binary Reports redundant, the controller can
disable the Sensor Binary Report Commands completely. The following table shows the values to enable and disable the two configuration parameters.

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04
Configuration Value: 0x00
(Default) Sensor does NOT send Basic Sets to Node IDs in Association Group
2 when the sensor is restored (
Configuration Value: 0xFF
Sensor sends Basic Sets of 0x00 to nodes in Association Group2 when sensor is restored.
Configuration Value: 0x00
(Default) Sensor sends Senso
r Binary Reports when sensor is faulted and restored for backwards compatibility in
addition to Notification Reports.
Configuration Value: 0xFF
Sensor will send only Notification Reports and NOT Sensor Binary Reports w
hen the sensor is faulted and restored.
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Re-orient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment to an outlet on a different circuit from the receiver
Consult the dealer or an experienced radio/TV contractor for help.
Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void the user’s authority to operate the equipment.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et appareil
doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement de la dispositif.
FCC ID: XQC-PIRZ1 IC: 9863B-PIRZ1 Warranty
Ecolink Intelligent Technology Inc. warrants that for a period of 3 years from the date of purchase that this product is free from defects in material and workmanship. This warranty does not apply to damage caused by
shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper maintenance, failure to follow instructions or as a result of any unauthorized modifications.
If there is a defect in materials and workmanship under normal use within the warranty period Ecolink Intelligent Technology Inc. shall, at its option, repair or replace the defective equipment upon return of the equipment
to the original point of purchase.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink Intelligent
Technology Inc. neither assumes responsibility for, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this
product. The maximum liability for Ecolink Intelligent Technology Inc. under all circumstances for any warranty issue shall be limited to a replacement of the defective product. It is recommended that the customer check
their equipment on a regular basis for proper operation.

© 2015 Ecolink Intelligent Technology Inc. PN PIR -ZWAVE2 R1.04