ECOLINE TV7094, TV7091 Installation Instructions Manual

Day/Night Speed dome camera /
LCD-keyboard
INSTALLATION INSTRUCTIONS
TV7094
TV7091
1
Preface
thank you for purchasing this ECOLINE digital surveillance camera. You made the right decision in choosing this state-of-the-art technology.
This product complies with the current standards of domestic and European regulations. The CE has been proven and all related certifications are available from the manufacturer upon request.
To maintain this status and to guarantee safe operation, it is your obligation to observe these operating instructions!
This ECOLINE speed dome camera is used in combination with video sources (cameras) and recording devices (VHS or digital recorders) for the purpose of property surveillance. It enables the user to build up a flexible and wide ranging surveillance. Enclosed in a weatherproofed housing it is the ideal outdoor protection. Furthermore the ECOLINE speed dome camera offers 6 alarm inputs which interact with the camera position. Through its adjustable rotation speed, 360° endless rotation, 180° tilt angle and 128 preset position, the camera offers an easy setup and a comfortable usage.
Precautions
It must be ensured that the ECOLINE speed dome camera and connected components are kept free of moisture (cellars and similar surroundings are to be strictly avoided). Use of this product for other than the described purpose may lead to damage of the product. Non­compliant use may also be hazardous (e.g. short circuit, fire, electrical shock). The power unit is suitable for operation on the public power network with 230 Volt / 50 Hz (1.5A) alternating current.
No part of the product may be changed or modified in any way. Connection to the public power network is subject to country-specific regulations. Please be aware of applicable regulations in advance.
To avoid fire and injury, please observe the following:
Securely fasten the device
at a dry location in the building.
Ensure sufficient air
circulation.
Do not expose the device
to temperatures less than ­10°C or more than 50°C.
The device is designed for
indoor use only or for outdoor use with the suiteable outdoor housing.
Humidity must not exceed
90% (non-condensed).
Ensure that the voltage is
disconnected when
performing work on the device.
Please observe the following regulations to ensure trouble-free operation of your device:
The ECOLINE speed dome
camera is supplied with 12VDC power by an external transformer.
The transformer should be
connected to the 230VAC building mains by means of a separate, electrically protected line.
Connection work to the
building mains is subject to country-specific regulations.
2
General:
Improper or careless installation work may lead to faults and poor image quality. Therefore please read
the instructions very carefully and follow the installation instructions for lines and components precisely.
3
Content
SCOPE OF DELIVERY..................................................................................................................................5
IN CASE OF OUTDOOR INSTALLATION OF THE SPEED DOME, USE AN OUTDOOR HOUSING. ........5
OVERVIEW ..................................................................................................................................................7
SYMBOL DESCRIPTION ..............................................................................................................................7
COMPONENT AND STRUCTURE DESCRIPTION .......................................................................................8
CAMERA SETTING ......................................................................................................................................9
TERMINAL FOOT CONNECTION, DATA LINE AND SIGNAL LINE REGULATION ................................ 11
INSTALLATION OF THE SPEED DOME CAMERA.................................................................................... 12
BACK PANEL TERMINALS........................................................................................................................ 14
OPERATION.............................................................................................................................................. 15
KEYBOARD BUTTONS .............................................................................................................................. 17
SET PRESET...................................................................................................................................... 17
GO PRESET..................................................................................................................................... 18
AUTO PAN...................................................................................................................................... 18
AUTO FOCUS................................................................................................................................. 19
FOCUS CONTROL ......................................................................................................................... 19
IRIS CONTROL................................................................................................................................ 19
ALARM MANAGEMENT.......................................................................................................................... 21
ALARM INPUT................................................................................................................................. 21
ALARM OUTPUT ............................................................................................................................. 21
STOP ALARM CONDITION............................................................................................................ 21
OSD OPERATIONAL DESCRIPTION........................................................................................................ 22
SIMPLE OPERATIONAL REFERENCE TABLE............................................................................................ 25
CONNECTING PELCO-KEYBOARD (KBD200A/KBD300A) .................................................................. 26
TROUBLE SHOOTING............................................................................................................................... 29
TECHNICAL DATA ................................................................................................................................... 30
4
Scope of delivery
Packaging
ECOLINE speed dome camera
Power unit with connection cable
Installation guides
In order to control the speed dome camera, use the keyboard (TV7091)

In case of outdoor installation of the speed dome, use an outdoor housing.

5

(TV7092) (TV7093)

6

Overview

Speedy response with 26 times continuous
Electronic Zoom
Auto Iris and Manual Iris Control
Advanced DSP Camera, including Auto White Balance, Backlight Compensation and
Auto Iris Control.
360° Continuous Pan Rotation.
128 Preset Points Setup.
Continuous Auto Focus
Variable Speed 1°~300°/Sec
Horizontal Rotation of 180°.
Built in 6 Alarm Inputs and one Relay Output
Two types of Alarm out signal are provided: NO and NC.
Remote Control via RS-485
Connects up to 127 Speed Dome Cameras.
Supports PELCO protocol (D and P protocol)
PC Control is applicable after transformation using the Communication Interface has
been completed.
auto-focus zoom lens and 10 times
12VDC Power Input (AC100
Suitable for installation on different occasions; can be installed outside (with outdoor
dome housing), flush mount on a ceiling or in the ceiling with only the dome showing
UVV certified
240V, 50Hz or 60Hz)

Symbol description

Function keys are shown by, framed capital boldface print letters.
Example: ENTER , AUTO FOCUS , etc.
Function key “+” indicates the order sequence.
Example: 2 8 + ENTER meaning, press the function key “ 2 “, ” 8 ”, and then ENTER .
_ :001 DEVICE
; indicate messages from the device and is shown on the control
⎢ ⎣
keyboard
LCD display.
⎤ ⎥
.
n” indicates the ID number of the nth device (ID numbers ranges from 001~127).
7

Component and structure description

(2)
(1)
(3)
(4)
(1) Elektronic Alarm input or output / Video input / Power input terminal (2) Elektronic ID position setup (3) Elektronic Embellish Cover (4) Mechanic Machine housing (5) Camera
module
Transparent cover / Black housing
(5)
8

Camera setting

SW1: ID number setting
DIP switch setting according to ID number:
Connection of up to 127 Speed Dome Cameras, each camera has its own ID number. Please setup each camera with its own ID number. Else the system is not able to differentiate between the different camera modules. Start with ID number
001.
DIP-Schalter SW1
Setting an ID to 000 will lead the display to print DEVICE N/A .
9
SW2: Protocol setup
Setup
DIP switch number
#4 #3 #2 #1 Off Off Off Off YOKO Off Off Off On PELCO Off Off On Off Reserviert Off Off On On Reserviert
* Speed dome automatically detects the type of PELCO Protocol. No switch settings are required to set D and P Protocols.
SW3: Baud rate settings
Setup
DIP switch number
#4 #3 #2 #1 Off Off Off Off 9600 BPS Off Off Off On 4800 BPS (P) Off Off On Off 2400 BPS (D) Off Off On On 19200 BPS
* Setup for YOKO-protocol: SW2: Off Off Off Off, SW3: Off Off Off Off
Applied protocol
Baud-Rate
10