Ecoflam MULTICALOR BROCHURE

Page 1
DUAL FUEL RANGE
MULTICALOR
www.ecoam-burners.com
Page 2
CUSTOMIZED BURNERS SOLUTIONS FOR ANY TYPE OF APPLICATION
OUR EXPERIENCE
Thanks to almost 50 years of experience in the design and production of burners, Ecoam offers a full range of blown air pressure jet burners covering an extremely wide range of power, from small products for residential heating appli­cations to high power burners dedicated to the industrial segment. Ecoam burners are renowned worldwide for providing high efciency and reliable operation with signicant ener­gy savings and feature extreme ease of installation, main­tenance and exible boiler-burner matching.
OUR MISSION
Following a philosophy of continuous improving, the R&D Laboratory is constantly working to produce better results, such as the reduced NOx level emissions. The development of new advanced combustion tech­nologies allows to propose solutions in respect of the most stringent environmental regulations and to create the perfect condition to face the new upcoming market requests, such as Ultra Low NOx performance and ErP­ready products.
OUR PRODUCT RANGE
The exibility of Ecoam solutions allows the manufacturing of highly customized products covering a range from 17 kW to 34 MW:
MAX GAS
17 - 700 kW
2
BLU
245 - 17000 kW
MAX
Light oil range
18 - 546 kW
MAIOR
Light oil range
300 - 17000 kW
MAXFLAM/OILFLAM
Heavy oil range 68 - 17000 kW
Page 3
OUR INTERNATIONAL APPROACH
Our products are designed, developed and manufactu­red in Italy, combining quality, reliability and high perfor­mance. All these features are necessary for the end-user satisfaction, which is the rst target for Ecoam. Reaching this outcome throughout its extensive worldwide network of distributors and customers has always been a challen­ging task for Ecoam, which was achieved only by deve­loping a close and personalized relationship with each customer, always taking into account the needs and the distinctive characteristics of each individual market.
OUR PROFESSIONAL TEAM
Ability to design state-of-the-art burners, manage demands of products for specic applications, ability to solve pro­blems in real time are just some of the characteristics of our technicians and engineers. But not only: Ecoam has a worldwide network of service technicians able to support the installation, the commissio­ning and the periodic maintenance activities of the burner.
MULTICALOR
Dual fuel (gas/light oil)
190 - 17000 kW
MULTIFLAM
Dual fuel (gas/heavy oil)
414 - 17000 kW
TS RANGE
All fuels
230 - 34000 kW
SPECIAL
VERSIONS
3
Page 4
Fuel Range
DUAL FUEL (GAS/LIGHT OIL) MULTICALOR
RANGE OVERVIEW
MULTICALOR 45
MULTICALOR 70
MULTICALOR 100
MULTICALOR 140
MULTICALOR 170.1
MULTICALOR 200.1
MULTICALOR 300.1
MULTICALOR 400.1
MULTICALOR 500.1
MULTICALOR 600.1
MULTICALOR 700.1
MULTICALOR 800.1
MULTICALOR 1000.1
MULTICALOR 1200.1
MULTICALOR 1500.1
MULTICALOR 1800.1
190 ... 500 kW
190 ... 700 kW
200 ... 1000 kW
250 ... 1300 kW
0 400 800 1200 1600 2000 kW
342 ... 1770 kW
414 ... 2150 kW
630 ... 3000 kW
875 ... 3900 kW
1200 ... 5000 kW
1500 ... 5800 kW
1500 ... 7500 kW
2000 ... 8500 kW
2500 ... 10500 kW
2700 ... 13000 kW
3690 ... 15000 kW
4000 ... 17000 kW
0 4000 8000 12000 16000 20000 kW
MAIN FEATURES
• Two stage version with electric
servomotor and integrated system for the regulation of air and fuel (from MULTICALOR 45 to MULTICALOR 200.1)
• Progressive version with electric
servomotor and double adjustable mechanical cam that allows air and fuel ne tuning
MULTICALOR 70 MULTICALOR 100
• Version with fully electronic Burner
Management System available for all models
• Adjustable combustion head for easy
regulation and matching with diffe­rent combustion chambers
• Congurated and special versions
on request according to feasibility
MULTICALOR 300.1 PR/AB
4
Page 5
CONFIGURATIONS
MULTICALOR range is available in the following operation modes:
MULTICALOR Two stages in gas and in light oil MULTICALOR 45 ... 200.1
MULTICALOR ... PR/AB Two stage progressive/modulating mechanical in gas / two stages in light oil MULTICALOR 70 PR/AB ... 200.1 PR/AB
MULTICALOR ... PR Two stage progressive/modulating mechanical in gas and in light oil MULTICALOR 70 PR ... 1800.1 PR
MULTICALOR ... PRE Two stages progressive/modulating electronic in gas and in light oil MULTICALOR 70 PRE ... 1800.1 PRE
Other available congurations:
• Continuous ventilation versions
• Swirl system for ame geometry customization
• OEM and special versions on request according to feasibility
FUEL
• Natural gas (G20, G25 according to EN676)
• LPG
• Light oil (viscosity from 1,6 cSt to 6 cSt
at 20°C)
EMISSIONS
Class
1 170
2 120
3 80
All models are in compliance with EN 676 and EN 267 European Standard
Gas
NOx mg/kWh
Class
1 250
2 185 3 120
Oil
NOx mg/kWh
MULTICALOR 1200.1 PRMULTICALOR 800.1 PR
CONFORM TO
All products are built in accordance with the following directives:
• 2006/42/EC Machinery Directive
• 2014/30/UE EMC Directive
• 2014/35/UE Low Voltage Directive
• 2009/142/CEE Gas Appliances Directive
5
Page 6
Range Models
MULTICALOR 45 - 70 - 100 - 140
• Fuel: natural gas, LPG; light oil (viscosity from 1,6 cSt to 6 cSt at 20°C)
• Operation: two stages
• Emission class: Low NOx class 2 (≤120 mg/kWh) according to EN676 in gas and class 1 (≤250 mg/kWh) according to EN267 in oil
WORKING DIAGRAM
mbar 10
8
MULTICALOR 45
6
4
2
Backpressure in the combustion chamber
MULTICALOR 70
MULTICALOR 100 MULTICALOR 140
Test conditions conforming to EN676 and EN267
Temperature: 20°C
Pressure: 1013,5 mbar
Altitude: 0 m a.s.l.
0
0
200 400 600 800 1000 1200 1400 kW
Burner output
TECHNICAL DATA
Burner output (kW) Flow rate (kg/h) Power supply Motor (kW) NOx class Operation
MULTICALOR 45 190 - 500 16 - 42,2 3/230-400/50Hz 0,55 Class 2 / Class 1 2 stages
MULTICALOR 70 250 - 700 21 - 59 3/230-400/50Hz 1,1 Class 2 / Class 1 2 stages
MULTICALOR 100 300 - 1000 25,3 - 84,3 3/230-400/50Hz 1,1 Class 2 / Class 1 2 stages
MULTICALOR 140 400 - 1300 33,1 - 110 3/230-400/50Hz 2,2 Class 2 / Class 1 2 stages
OVERALL DIMENSIONS
A
D/D1E
F
G
H1
N
B C
O
M
I
L
Head lenght: D short / D1 long
*: with silencer (optional)
A B C D D1 E F G H1* I L M N O
MULTICALOR 45 1045 510 535 175 335 555 160 390 600 190 190 M10 140 165
MULTICALOR 70 1045 510 535 175 395 555 180 390 600 190 190 M10 140 165
MULTICALOR 100 1045 510 535 17 5 395 555 190 390 600 190 190 M10 140 165
MULTICALOR 140 1070 510 560 307 457 555 215 390 600 190 190 M10 140 165
6
Dimensions in mm
Page 7
Range Models
MULTICALOR 70 - 100 - 140
• Fuel: natural gas, LPG; light oil (viscosity from 1,6 cSt to 6 cSt at 20°C)
• Operation: two stage progressive or modulating with the installation of a power regulator and dedicated probes in gas operation and two
stages (AB-PR versions) or two stages progressive (PR versions) in light oil operation
• Emission class: Low NOx class 2 (≤120 mg/kWh) according to EN676 in gas and class 1 (≤250 mg/kWh) according to EN267 in oil
WORKING DIAGRAM
mbar 10
8
6
4
2
Backpressure in the combustion chamber
MULTICALOR 70 MULTICALOR 100 MULTICALOR 140
Test conditions conforming to EN676 and EN267
Temperature: 20°C
Pressure: 1013,5 mbar
Altitude: 0 m a.s.l.
0
0
200 400 600 800 1000 1200 1400 kW
Burner output
TECHNICAL DATA
Burner output (kW) Flow rate (kg/h) Power supply Motor (kW) NOx class Operation
MULTICALOR 70 190 - 700 16 - 59 3/230-400/50Hz 1,1 Class 2 / Class 1 PR-AB, PR, PRE
MULTICALOR 100 200 - 1000 16,9 - 84,3 3/230-400/50Hz 1,1 Class 2 / Class 1 PR-AB, PR, PRE
MULTICALOR 140 250 - 1300 21,1 - 110 3/230-400/50Hz 2,2 Class 2 / Class 1 PR-AB, PR, PRE
OVERALL DIMENSIONS
A
D/D1E
F
G
H1
N
B C
O
M
I
L
Head lenght: D short / D1 long
Dimensions in mm
*: with silencer (optional)
A B C D D1 E F G H1* I L M N O
MULTICALOR 70 PR-AB 780 330 450 175 395 555 180 390 600 190 190 M10 140 165
MULTICALOR 100 PR-AB 780 330 450 17 5 395 555 190 390 600 190 190 M10 140 165
MULTICALOR 140 PR-AB 800 350 450 307 457 555 215 390 600 190 190 M10 140 165
MULTICALOR 70 PR 1045 510 535 17 5 395 760 180 390 600 190 190 M10 140 165
MULTICALOR 100 PR 1045 510 535 17 5 395 760 190 390 600 190 190 M10 140 165
MULTICALOR 140 PR 1070 510 560 307 457 76 0 215 390 600 190 190 M10 140 165
7
Page 8
Range Models
MULTICALOR 170.1 - 200.1
• Fuel: natural gas, LPG; light oil (viscosity from 1,6 cSt to 6 cSt at 20°C)
• Operation: two stages and two stage progressive or modulating with the installation of a power regulator and dedicated probes
• Emission class: Low NOx class 2 (≤120 mg/kWh) according to EN676 in gas and class 1 (≤250 mg/kWh) according to EN267 in oil
WORKING DIAGRAM
mbar 12
10
8
6
4
2
Backpressure in the combustion chamber
MULTICALOR 170.1
MULTICALOR 200.1
Test conditions conforming to EN676 and EN267
Temperature: 20°C
Pressure: 1013,5 mbar
Altitude: 0 m a.s.l.
0
0 400 800 1200 1600 2000 2400 kW
Burner output
TECHNICAL DATA
Burner output (kW) Flow rate (kg/h) Power supply Motor (kW) NOx class Operation
MULTICALOR 170.1 342 - 1770 29 - 150 3/230-400/50Hz 3 Class 2 / Class 1 2 stages, PR-AB, PR, PRE
MULTICALOR 200.1 414 - 2150 35 - 182 3/230-400/50Hz 4 Class 2 / Class 1 2 stages, PR-AB, PR, PRE
OVERALL DIMENSIONS
A
E
H1
D/D1
F
O
N
G
I
O
0
1
2 3
0
1
2
CB
M
SUNTEC
I
L
Head lenght: D short / D1 long
*: with silencer (optional)
A B C D D1 E F G H1* I L M N O
MULTICALOR 170.1 965 395 570 290 490 700 250 420 680 240 240 M14 125 250
MULTICALOR 200.1 990 420 570 290 490 700 270 420 680 240 240 M14 125 250
MULTICALOR 170.1 PR/AB 950 400 550 290 490 770 250 420 680 240 240 M14 125 250
MULTICALOR 200.1 PR/AB 950 400 550 290 490 770 270 420 680 240 240 M14 125 250
MULTICALOR 170.1 PR 1030 520 510 290 490 820 250 420 680 240 240 M14 125 250
MULTICALOR 200.1 PR 1030 520 510 290 490 820 270 420 680 240 24 0 M14 125 250
8
Dimensions in mm
Page 9
6000 kW
Range Models
MULTICALOR 300.1 - 400.1 - 500.1 - 600.1
• Fuel: natural gas, LPG; light oil (viscosity from 1,6 cSt to 6 cSt at 20°C)
• Operation: two stage progressive or modulating with the installation of a power regulator and dedicated probes
• Emission class: Low NOx class 2 (≤120 mg/kWh) according to EN676 in gas and class 1 (≤250 mg/kWh) according to EN267 in oil
WORKING DIAGRAM
mbar 25
20
15
10
MULTICALOR 300.1
5
Backpressure in the combustion chamber
0
0
1000 2000 3000 4000 5000
Burner output
MULTICALOR
400.1
MULTICALOR
500.1
MULTICALOR
600.1
Test conditions conforming to EN676 and EN267
Temperature: 20°C
Pressure: 1013,5 mbar
Altitude: 0 m a.s.l.
TECHNICAL DATA
Burner output (kW) Flow rate (kg/h) Power supply Motor (kW) NOx class Operation
MULTICALOR 300.1 630 - 3000 53 - 253 3/400/50Hz 5,5 Class 2 / Class 1 PR, PRE
MULTICALOR 400.1 875 - 3900 74 - 330 3/400/50Hz 7,5 Class 2 / Class 1 PR, PRE
MULTICALOR 500.1 1200 - 5000 101 - 423 3/400/50Hz 11 Class 2 / Class 1 PR, PRE
MULTICALOR 600.1 1500 - 5800 126 - 490 3/400/50Hz 15 Class 2 / Class 1 PR, PRE
OVERALL DIMENSIONS
D/D1E
F
O
N
G
H1
I
O
A
B C
0
1
2 3
0
1
2
M
SUNTEC
I
L
Head lenght: D short / D1 long
Dimensions in mm
*: with silencer (optional)
A B C D D1 E F G H1* I L M N O
MULTICALOR 300.1 1230 610 620 330 530 900 290 471 74 6 315 315 M16 195 250
MULTICALOR 400.1 1230 610 620 345 545 900 320 471 74 6 315 315 M16 195 250
MULTICALOR 500.1 1200 590 610 355 555 1000 320 570 965 330 330 M16 195 250
MULTICALOR 600.1 1200 590 610 355 555 1000 320 570 965 330 330 M16 195 250
9
Page 10
Range Models
MULTICALOR 700.1 - 800.1 - 1000.1 - 1200.1
• Fuel: natural gas, LPG; light oil (viscosity from 1,6 cSt to 6 cSt at 20°C)
• Operation: two stage progressive or modulating with the installation of a power regulator and dedicated probes
• Emission class: Low NOx class 2 (≤120 mg/kWh) according to EN676 in gas and class 1 (≤250 mg/kWh) according to EN267 in oil
WORKING DIAGRAM
mbar 40
32
24
MULTICALOR 800.1
MULTICALOR 700.1
16
8
Backpressure in the combustion chamber
MULTICALOR
1000.1
MULTICALOR 1200.1
Test conditions conforming to EN676 and EN267
Temperature: 20°C
Pressure: 1013,5 mbar
Altitude: 0 m a.s.l.
0
0
2000 80004000 10000 120006000 14000 kW
Burner output
TECHNICAL DATA
Burner output (kW) Flow rate (kg/h) Power supply Motor (kW) NOx class Operation
MULTICALOR 700.1 1500 - 7500 126 - 634 3/400/50Hz 15 Class 2 / Class 1 PR, PRE
MULTICALOR 800.1 2000 - 8500 169 - 718 3/400/50Hz 18,5 Class 2 / Class 1 PR, PRE
MULTICALOR 1000.1 2500 - 10500 211 - 887 3/400/50Hz 22 Class 2 / Class 1 PR, PRE
MULTICALOR 1200.1 2700 - 13000 228 - 1099 3/400/50Hz 37 Class 2 / Class 1 PR, PRE
OVERALL DIMENSIONS
E
H1
D/D1
F
O
G
N
A
B
0
I
1 2
O
3
0
1 2 3
C
SUNTEC
M
I
L
Head lenght: D short / D1 long
A B C D D1 E F G H1* I L M N O
MULTICALOR 700.1 137 0 740 630 470 - 1640 420 775 1270 460 460 M20 195 232
MULTICALOR 800.1 137 0 74 0 630 470 - 1640 420 775 1270 460 460 M20 195 232
MULTICALOR 1000.1 1 370 74 0 630 47 0 - 1640 420 775 1270 460 460 M20 195 232
MULTICALOR 1200.1 1430 800 630 47 0 - 1640 450 775 1270 460 460 M20 195 232
10
Dimensions in mm
*: with silencer (optional)
Page 11
SUNTEC
1
0
2 3
I
O
1
0
2
M
L
I
D / D1E
N
O
D / D1E
B C
A
A
H1
H1
F
F
G
N
G
O
B C
A
SUNTEC
1
0
2 3
I
O
1
0
2
B C
A
Range Models
MULTICALOR 1500.1 - 1800.1
• Fuel: natural gas, LPG; light oil (viscosity from 1,6 cSt to 6 cSt at 20°C)
• Operation: two stage progressive or modulating with the installation of a power regulator and dedicated probes
• Emission class: Low NOx class 2 (≤120 mg/kWh) according to EN676 in gas and class 1 (≤250 mg/kWh) according to EN267 in oil
WORKING DIAGRAM
mbar 40
32
MULTICALOR 1500.1
24
16
8
Backpressure in the combustion chamber
MULTICALOR 1800.1
Test conditions conforming to EN676 and EN267
Temperature: 20°C
Pressure: 1013,5 mbar
Altitude: 0 m a.s.l.
0
0
2000 80004000 10000 12000 14000 160006000 18000 20000 kW
Burner output
TECHNICAL DATA
Burner output (kW) Flow rate (kg/h) Power supply Motor (kW) NOx class Operation
MULTICALOR 1500.1 3690 - 15000 312 - 1268 3/400/50Hz 45 Class 2 / Class 1 PR, PRE
MULTICALOR 1800.1 4000 - 17000 338 - 1437 3/400/50Hz 55 Class 2 / Class 1 PR, PRE
I
OVERALL DIMENSIONS
DE
B C
F
O
N
H1
G
L
M
Dimensions in mm
Head lenght: D short / D1 long
*: with silencer (optional)
A B C D D1 E F G H1* I L M N O
MULTICALOR 1500.1 1700 800 900 590 - 1910 550 1320 1670 619 619 M20 210 320
MULTICALOR 1800.1 1770 870 900 590 - 1910 550 1320 1670 619 619 M20 210 320
11
Page 12
HEAD OFFICE: Via Roma, 64 31023 Resana (TV)
Company subject to the direction and coordination of Ariston Group, Via A. Merloni, 45 - 60044 Fabriano (AN) - Italy
REGISTERED OFFICE: Viale A. Merloni, 45 60044 Fabriano (AN)
Tel.: +39 0423 719500 Fax: +39 0423 719580 Email: export@ecoam-burners.com
Version 1.2 - 01/02/2022
ECOFLAM Bruciatori S.p.A. reserve the right to make any adjustments, without prior notice, which is considered necessary or useful to its products, without affecting their main features.
www.ecoam-burners.com
Loading...