EST Install and User Guide
07.2019
21/28
www.ecoer.com
Manufacturer reserves the right to change specifications or designs without notice.
System Types List
Type Descriptions Application Required Terminals
0 Cool only ESI (AC only)
C, RC, Y1, G
1 W2
Gas or Oil Furnace
C, RH, W2, G
Hot Water Boiler
C, RH, W2
2 Cool only + W2 ESI (AC only) + Furnace
C, RC, Y1, W2, G
3 Cool only ESI + Air Handler
C, RC, Y1, O, G
4 Heat only ESI + Boiler/(Furnace)
C, RH, Y1, *O, W2, (G)
5 Heat only (2 Stage) No
C, RH, Y1, Y2 , O, *W2, G
6 1H/1C ESI + Air Handler
C, RH, Y1, O, G, *W2
7 2H/1C No
C, RH, Y1, Y2 , O, G, *W2
8 1H/1C ESI + Air Handler
See following Pages
9 1H/1C (G/G2) ESI + E series Air Handler
10
(Default)
2H/1C
ESI + Air Handler
ESI + Gas Furnace
11 2H/1C (G/G2) ESI + E series Air Handler
12 Cool only (G/G2)
AC only + E series Air Handler
13 Cool only (G/G2) + W2
Remarks:
ESI- Ecoer Smart Inverter condensing unit
* means optional connection