Ecoboil EC 30 Installation And Maintenance Instructions Manual

Page 1
Water boilers | Water chillers | Boil/Hot units | Boil/Hot/Chill units | Parts & Accessories
EC 30 Arctic Chiller
Automatic Under Bench Water Chillers
Installation and maintenance instructions
Please read prior to installation
Important
This unit must be installed by an authorised plumber
or AS/NZS 3500.4.2
Do not turn on power to this chiller until water is flowing
from the tap
Please leave these instructions with the owner
WHAT’S IN THE BOX:
1 x EC 30 Chiller Unit 1 x UBFKI 10C Filter Kit (kit includes EC 02 Chiller/Filter Tap and EB FMP 350 kPa PLV)
Page 2
Prior to installation
• This unit is intended to be installed underneath a conventional kitchen sink. However as a refrigeration unit it relies upon air exchange to function properly, ensure adequate ventilation is provided.
• When fitting this unit in a cupboard leave 25mm in the front and back of the unit and 50mm either side of the unit.
• Only Teflon tape to be used where necessary. Under no circumstances is plumbing paste to be used.
Product Information
• The 350 kPa Pressure Limiting Valve supplied must be fitted.
• Do not tip chiller unit on its side or end, if this has happened
reposition and wait 30 minutes for the oils to return.
• We recommend changing the filter cartridge every 12 months.
• The condenser should be periodically cleaned with a brush air
hose or vacuum cleaner. Disconnect the power supply during cleaning.
• If the supplied power cord is damaged, it must be replaced by an electrician.
• Temperature control is adjustable, with a cooling capacity of 2-12 degrees Celsius.
Installation Instructions
1. Do not plug in the unit or turn on the power until the installation
process is complete.
2. Position the unit underneath the sink so that the chiller air-intake
is as close as possible to the front of the cupboard. The cupboard floor which extends past the toe-board must have a slot cut into it to provide the necessary ventilation (preferably at least 20mm wide by 3/4 the width of the cupboard door).
3. Ensure the connecting lines are thoroughly flushed to remove all
foreign matter before connection to the chiller.
4. Position the tap in the desired location. Drill an 11mm hole to fit.
5. Secure the 10” Water Filter, with the bracket and screws
provided, to the cupboard wall in a handy position relative to the
Page 3
Main water line as shown in the diagram, taking careful note of the flow direction.
6. Use the quick fit ends to connect the blue 1/4” line
7. Now connect the hose to the Filter Tap to the units as follows:
a. Connect the 1/4” pipe from the tap to the chiller outlet port. b. Connect the 1/4” pipe from the filter outlet to the chiller inlet. c. Connect the 1/4” pipe from the filter inlet to the 350 kPa PLV. d. Connect to the mains water supply using Plumber’s Mate fitting provided.
8. Open tap until water is flowing from the spout. Once the water
is flowing freely out of the tap plug in the unit to a standard 3 Pin 10 Amp Power Socket and switch on the power. Allow 20 minutes for the initial chill cycle before using.
9. Check for leaks at all connections.
Page 4
Trouble Shooting
SYMPTOM CAUSES ACTION
Water not cold No power supply
Thermostat
Loss of gas
Failed fan
Check and test power supply
Not set correctly
Contact Supplier
Contact Supplier
Slow water flow Old water filter
Blocked PLV
Replace filter cartridge
Contact Supplier for a service
No water Water has been
turned off
Blocked filter
Check Mains water supply
Replace filter cartridge.
Water boilers | Water chillers | Boil/Hot units | Boil/Hot/Chill units | Parts & Accessories
For more information about Ecoboil and our products,
visit our website or contact us:
Ecoboil Appliances Limited
Phone 09 238 2209
Fax 09 282 4073
Mail P.O. Box 940, Pukekohe 2340
Web www.ecoboil.co.nz