Ecobee B1338807 User Manual

Page 1
©2012 ecobee 333 Adelaide Street West | 6th Floor Toronto | Ontario | M5V 1R5 | Canada Toll free 1.877.932.6233 www.ecobee.com
MA-EMSSi-01-rev1
Page 2
EMS Si
Manual
Page 3
GETTING STARTED 1
Before You Begin 2 HVAC System Compatibility Information 3 Approvals 4 FCC Compliance Statement 4 Specications 5 Wiring Requirements 6
INSTALLING THE EMS Si 7
Step 1. Power O HVAC Equipment 7 Step 2. Remove Existing Thermostat 7 Step 3. Install the EMS Si 7 Step 4. Connect the Wiring 9 Step 5. Power On HVAC Equipment 20
NAVIGATING THE MENUS 20
Using the Navigation Buttons 20
CONFIGURING THE HVAC SETTINGS 22
Equipment 22 Thresholds 25 Reset HVAC Equipment Settings 29 Performing a Hardware Reset 29 Rebooting the EMS Si 30 Conguring Reminders and Alerts 31 Alerts 32
Page 4
AUTOMATION 34
Setting Up the Sensor Inputs 34
CONNECTING TO THE INTERNET 38
Setting Up WiFi and Obtaining a Registration Code 39 Conguring a Web Portal Account 40
USING YOUR EMS Si 42
System Mode 43 Fan 43 Weather Forecast 45 Cleaning the EMS Si 45
CONFIGURING YOUR EMSSi 46
Conguring Personal Preferences 46 Utility CPP Setting 50 WiFi 52 Creating Your Weekly Schedule 53 Using the Weekly Schedule Editor 54 Scheduling a Calendar Event 55
3-YEAR LIMITED WARRANTY 57
END-USER SOFTWARE LICENSE AGREEMENT 59
Page 5
Page 6
GETTING STARTED
Welcome
The ecobee Energy Management System Si (EMS Si) is the newest technology designed for the commercial market. It is ideal in applications where a simple programmable Thermostat does not provide adequate controls and functionality and a full-scale building automation system is too complex and cost prohibitive. The ecobee EMS Si is user-friendly, reduces a building’s operating costs, and delivers increased energy conservation.
From their EMS Web Portal, users can remotely monitor, identify, analyze and troubleshoot performance issues; manage the temperature and operational settings from a central location; and take action without having to send a technician on-site.
The ecobee EMS Si can maximize any building’s eciency, reduce energy consumption and deliver signicant cost savings
Technical Support
Our technical support team is available to answer your questions at 1.877.932.6233, or via email at support@ecobee.com.
1
Page 7
Before You Begin
This product is intended to be installed by trained service professionals.
This manual explains the procedures for installing the ecobee EMS Si. Please read it carefully before beginning the installation.
The EMS Si is designed to be mounted on the wall in a convenient location.
OK
MENU BACK
ecobee
Caution: Disconnect electric power to the HVAC
!
system before installing this product. Failure to do so could result in electric shock and/or equipment damage.
All wiring must conform to your local electrical code.
Mercury Notice: This product does not contain mercury. If you are replacing a product that does contain mercury, contact your local waste-management authority for disposal instructions. Do not discard the old product in the regular trash.
2
Page 8
HVAC System Compatibility Information
The EMS Si is designed to operate with low­voltage heating and cooling systems. It is not designed for use with line-voltage or millivolt heating and cooling systems.
The EMS Si supports:
Up to 2 heat and 2 cool stages on a
conventional system.
Up to 3 heat and 2 cool stages on a heat
pump system.
The ecobee EMS Si supports the following equipment:
Equipment Supported?
Gas/Oil/Electric heating Yes (up to two stages)
Heat pump with auxiliary heat Yes (up to three stages)
Geothermal Heat Pump Yes
Dual fuel systems Yes
Standard electric cooling Yes (up to two stages)
Boilers Yes
Sensors with dry contact outputs Yes
3
Page 9
Approvals
This product was designed and built in accordance to RoHS directive 2002/95/EC and contains no hazardous substances as dened by this directive.
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment
and receiver.
Connect the equipment to an outlet on a dierent
circuit from the receiver.
Consult the dealer or an experienced radio/TV
contractor for help.
To satisfy FCC/IC RF exposure safety requirements, a separation distance of 8 inches (20 cm) or more should be maintained between this device and persons. To ensure compliance, operation at closer than this distance is not allowed.
4
Page 10
FCC ID: WR9EBSTAT IC: 7981A-EBSTAT
Warning: Changes or modications not expressly approved by ecobee Inc. could void the user’s authority to operate the equipment.
Specications
Temperature ranges
Heat: 45 to 79 °F (7 to 26 °C) Cool: 45 to 92 °F (14 to 33 °C) Display: 40 to 100 °F (5 to 37 °C) Sensitivity: +/- 1 °F (0.5 °C) Operating: 32 to 130 °F (0 to 55 °C)
Humidity Range
Display: 20 to 90% R.H. Sensitivity: +/- 5% R.H. Operating: 5 to 95% R.H (non-condensing)
Dimensions
Thermostat: 5.5”W x 3.25”H x 1”D (139.5mm H x 82.5mm W x 25mm D)
Power
24 VAC (3VA minimum)
5
Page 11
Wiring Requirements
The following table shows the maximum wire lengths allowed:
Thermostat to HVAC Equipment
18 AWG 20 AWG 22 AWG
128 ft/380 m 80 ft/240 m 50 ft/150 m
Terminal Description and Electrical Ratings
Terminal Description Voltage Current Max
N/C Unused N/A N/A
Y 1st stage compressor 30V AC 3A
W (O/B) 1st stage heating 30V AC 3A or reversing valve changeover
G Fan 30V AC 3A
RC Cool transformer * 30V AC 3A
RH Heat transformer * 30V AC 3A
C Common 30V AC 3A
Y2 2nd stage compressor 30V AC 3A
W2 (AUX) 2nd stage heating or 30V AC 3A 1st stage auxiliary heat
R1+ Input 1+ Dry contact only
R1- Input 1- Dry contact only
R2+ Input 2+ Dry contact only
R2- Input 2- Dry contact only
* Factory jumper installed between RC and RH. Remove jumper for 2-transformer applications. See wiring diagrams for additional information.
6
Page 12
INSTALLING THE EMS Si
There are 5 steps to install the ecobee EMS Si:
Step 1. Power O HVAC Equipment
Step 2. Remove Existing Thermostat
Step 3. Install the EMS Si
Step 4. Connect the Wiring
Step 5. Power On HVAC Equipment
Step 1. Power O HVAC Equipment
Before disconnecting the existing thermostat, or installing the EMS Si, disconnect the power to the heating and air conditioning equipment.
Step 2. Remove Existing Thermostat
Disconnect the wires to the existing thermostat and remove it from the wall (if you are installing the EMS Si in the same location).
Step 3. Install the EMS Si
The ideal location for the thermostat is approximately 5 ft (1.5 m) above oor level in the main living area.
Do not install the thermostat:
Close to sources of heat such as incandescent lights
Near supply heating/cooling sources
In direct sunlight
On exterior, non-insulated or poorly insulated walls
In the kitchen or other areas of potentially high heat and/or
humidity
7
Page 13
In an area that could restrict air ow
To install the thermostat:
1. Gently separate the backplate from the thermostat.
2. Place the thermostat backplate on the wall. Make sure that any existing wires can be inserted through the opening for the wiring.
3. Using the backplate as a template, mark the location of the mounting holes on the wall as shown below.
W2
AUX
W
Y N/C
GRCRHCY2R1+R1-R2+R2-
O/B
The solid color indicates mounting holes
4. Move the backplate out of the way and make holes where indicated in step 3. The mounting holes can accommodate a #6 pan-head screw. It is recommended to use the included fasteners to ensure proper tting of the front housing.
5. Use the included drywall plugs (or other suitable anchors) to ensure the thermostat can be mounted securely to the wall.
6. Fasten the backplate to the wall using the screws provided (or other suitable screws).
8
Page 14
Step 4. Connect the Wiring
You need to use low-voltage cable to connect the thermostat to the HVAC equipment. Check the wiring diagrams on pages 8 to 17 for the number of wires required.
Note: There is a factory installed jumper between R/H and R/C. Ensure any unused wires do not have exposed bare copper conductors.
To connect the thermostat to the equipment:
1. Connect the wires as shown in the wiring diagrams.
2. Attach the EMS Si to the backplate. Ensure that the pins on the thermostat align with the terminal block on the backplate.
Wiring Diagrams
The following diagrams show how to connect the thermostat terminals to various HVAC equipment.
9
Page 15
1-stage AC
1-stage Furnace
24V
C
EMS Si Thermostat
Y
W
G
R
HUM
C
W2
AUX
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Single stage heat/cool
10
Page 16
2-stage AC
1-stage Furnace
Y1
Y2
R
C
EMS Si Thermostat
Y
W
G
R
HUM
C
W2
AUX
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Single stage heat, dual stage cool
11
Page 17
1-stage AC
24V
C
EMS Si Thermostat
2-stage Furnace
Y1
W1
G
W2
R
Y2
HUM
C
W2
AUX
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Dual stage heat, single stage cool
12
Page 18
2-stage Furnace
2-stage AC
Y1
Y2
R C
EMS Si Thermostat
Y1
W1
G
W2
R
Y2
HUM
C
W2
AUX
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Dual stage heat, dual stage cool
13
Page 19
1-stage Heat Pump
O
W2
Y
R C
EMS Si Thermostat
Air Handler
O
W
Y/Y2
G
R
C
W2
AUX
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Single stage heat pump with auxiliary heat
14
Page 20
2-stage Heat Pump
O
Y1
W2
Y2
R
C
EMS Si Thermostat
Air Handler
O
W
Y/Y2
G
R
C
W2
AUX
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Dual stage heat pump with auxiliary heat
15
Page 21
Boiler
R
C
W
EMS Si Thermostat
Air Handler
Y1
Y2
R
C
G
1-stage AC
24V
C
W2
AUX
* Remove RH/RC factory jumper
C terminal to be connected to heating
transformer common
16
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Boiler with air handler and single-stage cool
Page 22
2-stage Boiler
R
C
W2 W1
EMS Si Thermostat
Air Handler
Y1
Y2
R
C
G
1-stage AC
24V
C
W2
AUX
GRCRHCY2R1+R1-R2+R2-
* Remove RH/RC factory jumper
C terminal to be connected to heating
transformer common
Dual stage boiler with air handler and single stage cool
W
YN/C
O/B
17
Page 23
2-stage AC
RR
Air Handler
Y1
Boiler
R
C
Y2
C G
Y1
Y2
C
W
EMS Si Thermostat
W2
AUX
* Remove RH/RC factory jumper
C terminal to be connected to heating
transformer common
18
W
YN/C
GRCRHCY2R1+R1-R2+R2-
O/B
Single stage boiler with air handler, dual stage cool
Page 24
2-stage Boiler
RR
R
C
W1
W2
EMS Si Thermostat
Air Handler
Y1
Y2
C
2-stage AC
Y1
Y2
C
G
W2
AUX
GRCRHCY2R1+R1-R2+R2-
O/B
* Remove RH/RC factory jumper
C terminal to be connected to heating
transformer common
Dual stage boiler with air handler, dual stage cool
W
YN/C
19
Page 25
OK
Step 5. Power On HVAC Equipment
After you’ve completed the wiring, you can apply power to the heating and air conditioning equipment. The EMS Si receives power from the equipment and will automatically power on.
NAVIGATING THE MENUS
The EMS Si has an easy-to-read color screen that displays all the information you need to congure the thermostat. Use the navigation buttons on the right to quickly change the temperature, access features, and congure settings.
Using the Navigation Buttons
The navigation buttons located on the right of the EMS Si let you select options and control the EMS Si.
(up) On the Home screen, press to
increase the temperature set point by 1°F (0.5°C). For menus, press to move up.
(down) On the Home screen, press to
decrease the temperature set point by 1°F (0.5°C). For menus, press to move down.
◀ (left) On the Home screen, if Auto mode is
enabled, press to switch between heat and cool set points. For menus, press to go back to the previous screen.
20
Page 26
(right) On the Home screen, if Auto mode
is enabled, press to switch between heat and cool set points. For menus, press to choose the currently highlighted option.
OK On a menu screen, press OK to choose
the currently highlighted option. If a conguration option is selected, pressing OK will keep its new value and return back to the previous screen.
MENU Pressing MENU displays a list of all
available options. If a menu is currently displayed, pressing MENU will cancel any unsaved changes and return to the Home screen.
BACK On a menu screen, press BACK to go
back to the previous screen.
On-Screen Keyboard
If you need to type in any information, an on­screen keyboard will appear. To enter a letter or number, move to the character by pressing the arrow keys and then press OK to select it.
Select
make a mistake, press
To keep your changes, select your changes, press BACK.
to enter capital letters; select
to enter commonly used symbols. If you
to delete the text .
. To cancel
MENU
BACK
21
Page 27
To congure the equipment settings:
From the Home screen, press MENU.
Select Settings
Installation Settings.
Select Equipment.
Congure the devices connected to the EMS Si.
22
CONFIGURING THE HVAC SETTINGS
The rst step after installing the EMS Si is to congure the settings for the various devices (such as a furnace or air conditioner) that are being connected.
Equipment
The Equipment settings let you congure the devices connected to the thermostat.
Heat Pump
This section lets you congure a heat pump with up to 2 heat/2 cool stages plus an auxiliary heat source.
Geothermal heat pump Select Yes if you are
using a geothermal heat pump. This helps the thermostat determine optimum performance and default settings. If you select No, the system will optimize the settings for an air-to­air heat pump.
OB energize on cool If you choose Yes, the
reversing valve output (O/B terminal) will activate when there is a call for cooling. If you select No, the relay will activate when there is call for heat.
Min Cycle O Time Congures the minimum
compressor o time between cycles (240 to 900 seconds).
Min Outdoor Temp Disables the compressor
when the outside air temperature reaches the congured minimum setting. This performs two functions. It prevents the compressor
Page 28
from running when the outdoor temperature is too low, thus resulting in damage to the compressor. You can also set this value to determine when you want the auxiliary heat (if installed) to engage to help meet the set temperature. The temperature range is adjustable from 0 to 65 °F (–17.8 to 18.3 °C) or can be completely disabled. Note: You need an internet connection for this feature to operate properly.
Allow HP with Aux Heat If you select Yes
and there is a source of auxiliary heat, it will turn on in addition to the heat pump. The heat pump will be energized for the rst 30 minutes. If, after 30 minutes, the set point has not been met, the auxiliary heat will be energized to assist the heat pump in meeting the load.
If you select No, the heat pump will be
energized for up to 2 hours. If after 2 hours the set point has not been met, the thermostat will shutdown the heat pump and energize the auxiliary heat to meet the set point. This option should also be used for installation where the heat pump evaporator coil is downstream from the source of auxiliary heat.
This setting is only available the Comp to
Aux Temp Delta and Comp to Aux Runtime settings are both set to Auto (default)
23
Page 29
Furnace
Allows you to enable and congure up to a 2-stage conventional heat source. If you have selected a heat pump as your primary source, this feature allows you to congure the 1st stage of auxiliary heat connected to the system.
Furnace Type Allows you to congure the
type of furnace. This helps the thermostat optimize its algorithms based on the type of fuel and typical characteristics of the chosen system. Choose the option that best represents the type of heating system installed.
Heat Fan Control Congures the furnace fan
to be controlled by the EMS Si or the HVAC system during heat cycles. Normally the HVAC system controls the fan during heat cycles.
Air Conditioner
Congures up to 2 stages of air conditioning. If you require a second stage, you must enable the Y2 relay.
24
Page 30
Thresholds
This section congures the temperature and time thresholds associated with the heating and cooling equipment.
You must congure the Equipment settings (page 10) before setting the thresholds. Only the applicable threshold settings will be displayed (i.e. if no air conditioner is congured, you will not see the options related to air conditioners).
Allow Auto Heat/Cool
Enabling this option allows the user to select auto change-over as a system mode.
Heat/Cool Min Delta
The minimum dierence between the heat mode set temperature and the cool mode set temperature when the system mode is in auto change-over. The delta is adjustable from 2 to 10 °F (1.1 to 5.5 °C). The default value is 5 °F (2.8 °C).
Compressor Settings
Min Cycle O Time Congures the
compressor o time between cycles. This ensures the compressor does not short cycle (which could aect the operating life of the system). This time is adjustable from 240–900 seconds.
Min Outdoor Temp Congures the minimum
outside air temperature at which the compressor will be disabled. This performs two functions. It prevents the compressor from running when the outdoor temperature is too low, thus resulting in damage to the compressor. You can also set this value to determine when you want the auxiliary heat
To congure threshold settings:
From the Home screen, press MENU.
Select Settings
Installation Settings.
Select Thresholds.
Congure the temperature threshold settings.
25
Page 31
(if installed) to engage to help meet the set temperature. The temperature range is adjustable from 0 to 65 °F (–17.8 to 18.3 °C) or can be completely disabled. Note: You need an internet connection for this feature to operate properly.
Aux Heat Settings
Max Outdoor Temperature Congures the
maximum outdoor temperature threshold. Above this level, the auxiliary heat will not be activated. The temperature is adjustable from 0 to 80 °F (26.5 °C) in increments of 0.5°F (0.5°C). The default value is 70°F (21°C).
Common Heat/Cool Settings
Heat Dierential Temp The minimum
dierence between the current temperature and set temperature before the system calls for heat. A smaller dierence means shorter cycle times, whereas a larger dierence results in longer cycle times. The temperature range is adjustable form 0 to 3 °F (-17.5 to 26.5 °C) in
0.5°F (0.5°C) increments.
Heat Dissipation Time The amount of time
the fan will run after the heat set point has been reached and the call for heat has been turned o. Running the fan for a period of time allows for any heated air left in the ducts to circulate throughout the home. The time is adjustable from 0 to 900 seconds. The default value is 30 seconds.
Cool Dierential Temp The minimum
dierence between the current temperature and set temperature before the system calls for cool. A smaller dierence means shorter cycle times, whereas a larger dierence results
26
Page 32
in longer cycle times. The temperature range is adjustable from 0 to 3 °F (0.3 to 1.7 °C) in
0.5°F (0.3°C) increments.
Cool Dissipation Time The amount of time
the fan will run after the cool has been turned o. Running the fan for a period of time allows for any cooled air left in the ducts to circulate throughout the home. The time is adjustable from 0 to 900 seconds. The default value is 30 seconds.
Advanced Settings
These options customize how long each stage will run before the next stage turns on. You may also program when a particular stage is turned on based on the temperature delta between the set temperature and the current temperature.
Reverse Staging If enabled, the thermostat
will cycle down from the higher stages so that as it approaches set point it will only be running in stage 1. The HVAC equipment will start in stage 1. As the stage 1 temperature delta is exceeded, the second stage will engage. Once the equipment has brought the current temperature back to within the heat or cool dierential setting, stage 2 will disengage and stage 1 will remain running until the set point is meet.
Stage 2 Temp Delta The minimum dierence
between the current temperature and the set temperature that will activate the auxiliary heat (regardless if the maximum run time of the previous stage was reached). Options are Auto (default) and 1 to 10 °F (0.6 to 5.6 °C).
Stage 1 Max Runtime The maximum amount
of time stage 1 will run before engaging the
27
Page 33
next stage. Options are Auto (default) and 10 to 120 minutes.
Comp to Aux Temp Delta The maximum
amount of time this stage will run before engaging the next stage. Options are Auto (default) and 1 to 10 °F (0.6 to 5.6 °C).
Comp to Aux Runtime The minimum
dierence between the current temperature and the set temperature that will activate this stage (regardless if the maximum run time of the previous stage was reached). Options are Auto (default), Disabled, and 1 to 10 °F (0.6 to
5.6°C).
Cool Min On Time Sets the minimum
equipment run time in cool mode: 1 to 20 min (default is 5 min).
Heat Min On Time Sets the minimum
equipment run time in heat mode: 1 to 20 min (default is 5 min).
Temp Correction
Lets you program an oset between the real temperature at thermostat and the displayed temperature. If you nd that the temperature where the thermostat is located does not represent the room temperature, change the oset to compensate for the dierence. The correct temperature is adjustable from +/- 10°F in 0.5°F (0.3°C) increments.
Installer Code
To prevent accidental modications to the installation settings, you can enable a 4-digit installer code. This code is pre-programmed to
3262.
28
Page 34
Test Equipment
These options let you test the wiring and connections of the devices connected to the thermostat by turning them on or o.
The equipment will turn o when you exit the menu.
Warning: Compressor protection and
!
minimum run-time features are not enforced while in this mode.
Reset HVAC Equipment Settings
You can quickly restore all HVAC equipment
settings on the EMS Si back to their factory defaults. Any user setting (not related to the equipment installed) will remain unchanged.
If you need to reset the entire thermostat back to its original factory default settings, including user settings and registration, select Reset All
Settings instead.
Performing a Hardware Reset
In rare circumstances, static electricity or power surges may interrupt the operation of the thermostat, forcing a hardware reset.
To test the equipment:
From the Home screen, press MENU.
Select Settings
Installation Settings.
Select Test Equipment.
Select OK.
Test the equipment connected to the thermostat by turning each component on and o.
To reset the EMS Si:
From the Home screen, press MENU.
Select Settings Reset.
Select HVAC Equipment
Settings.
Select Ye s.
29
Page 35
Rebooting the EMS Si
You can reboot the EMS Si by pressing the physical hardware reset button, located through an opening in the bottom left corner of the EMS Si. Rebooting will not alter programming or conguration options.
Reset button
30
Page 36
Conguring Reminders and Alerts
The Reminders and Alerts list displays the reminders and alerts described below.
HVAC Service
The HVAC Service (maintenance) reminder generates an alert telling the homeowner that regularly scheduled maintenance is required.
This alert, along with technician contact information can be displayed on the screen. If homeowners register their thermostats, the reminders will be emailed to them and be displayed in the web portal.
You can set the Last Service date, turn the Reminder On or O, and to set the Frequency of the maintenance interval in months.
Furnace Filter
Generates an alert for cleaning or changing the lter. You can set the Last Filter Change date, turn the Reminder On or O, and set the Frequency of the maintenance interval.
UV Lamp
Sets the reminder period for cleaning or replacing the UV lamp. You can set the Last Lamp Change date, turn the Reminder On or O, and set the Frequency of the maintenance interval.
To congure Reminders and Alerts
From the Home screen, press MENU.
Select Reminders and
Alerts.
Congure the Reminder and Alert settings as required.
31
Page 37
Alerts
The EMS Si can generate alerts if the temperature in the home goes over or under a pre-programmed level. This protects the home from damage due to freezing and/or excessive heat.
This alert, along with optional technician contact information will be displayed on the screen. If the homeowner registers the thermostat, the alert will be emailed to them and be displayed in the web portal.
Low Temp Alert Sets the temperature at which
the thermostat will generate a Low Temperature Alert. The range can be:
O – no alert will be generated.
Set temperature range of 35 to 68 °F (1.5 to
20 °C).
High Temp Alert Sets the temperature at which
the thermostat will generate a High Temperature Alert. The range can be:
O – no alert will be generated.
Set temperature range of 60 to 104 °F (15.5
to 40 °C).
Display Alerts on Thermostat
Select No if you do not want any of the alerts to be displayed on the EMS Si screen. Alerts will continue to be displayed on the web portal and sent via email.
32
Page 38
Enable Heating/Cooling Alerts
Select No to disable alerts for heat/cool error conditions. If disabled, alerts indicating that the system failed to heat or cool will not be appear in the screen, web portal, or emails.
List of Alerts
Below is a complete list of alerts. Depending on your conguration, some of these may not apply.
Furnace Air Filter
UV Lamp
Low Temp Alert
High Temp Alert
Heat Not Responding
Cool Not Responding
Maintenance Reminder
Auxiliary Heat Run Time
Auxiliary Outdoor Temperature
Furnace lter needs to be cleaned or changed.
UV lamp needs to be changed.
Temperature in the home is too low.
Temperature in the home is too high.
The system has failed to heat the home.
The system has failed to cool the home.
HVAC system due for regular maintenance.
Auxiliary heat source is running too often.
Your EMS Si auxiliary heat has been called to run when the outdoor temperature exceeds the programmed set point.
33
Page 39
To congure sensors and automation
From the Home screen, press MENU.
Select Settings
Installation Settings.
Select Sensors.
Select the dry contact you want to view or edit.
Congure the sensor settings as required.
To create a new action, select Add New Action.
AUTOMATION
The EMS Si can be congured to perform actions based on the status of its 2 dry contact inputs.
You can have multiple actions per input. You can also have the same input perform dierent actions when it is open or closed. For example, if a window sensor is open, you can congure the system to adjust the temperature set point and disable the AC.
Setting Up the Sensor Inputs
The EMS Si system supports 2 dry contact inputs (R1 and R2). In order to use them, you need to ensure they are correctly congured.
Name
To enable, simply enter a name for this input (i.e. Door sensor). To disable this input, delete the name.
Type
Denes the type of input (only Dry Contacts are supported in this version).
Actions...
Lets you to view the current state and edit action options for a sensor. To add a new action, select
Add New Action.
State Congure if the circuit (contact) is Open
or Closed.
Type Select the action to perform from the
list:
34
Page 40
Do Nothing No specic action will occur.
Switch to Occupied* Switches the system
to the Occupied program when the input is activated.
Switch to Unoccupied* Switches the
system to the Unoccupied program when the input is activated.
* The Economizer and/or Occupancy relay
outputs, if congured, will also be switched to the appropriate state when this input is congured and activated.
Shutdown Compressor The compressor
(both for AC or Heat pump) will shutdown and remain shutdown until this input is cleared
Shut down AC The air conditioning system
will shutdown and will remain shutdown until this input has cleared
Adjust Temperature The heat and/
or cool set points will be adjusted by a preprogrammed amount. It will revert back to the original set point when the input has cleared.
Turn On Fan The fan will be set to On. It
will revert back to its original settings when the input is cleared.
Disable Auxiliary Heat The auxiliary heat
equipment will be disabled. It will be re­enabled when the input is cleared.
Shutdown All HVAC All equipment will be
disabled. It will be re-enabled when the input is cleared.
Disable All Heat All heat equipment will
be disabled. It wil be re-enabled when the
35
Page 41
input is cleared.
Send Alert Enables the system to send an
alert when the input has been activated.
Send Update Log Enables the system to log
when this input is activated.
Activation Delay Congures time delay from
when the input detects the active state to when the action programmed in the Type section is performed by the system. For example, if you connect a door sensor to the input and program a 5 minute activation delay, the door will need to open and remain open for 5 minutes before the thermostat takes action.
Deactivation Delay Congures a time delay
from when the input detects the inactive state to when the system reverts back to its normal operating conditions. For example, if you connect a door sensor to the input and program a 5-minute deactivation delay. The door will remain closed for 5 minutes before the thermostat will revert back to the normal operating condition.
Min Action Duration Congures the
minimum amount of time the system will perform this action. This timer will run its course regardless of whether the input has reverted back to its normal state and the deactivation timer has expired. This option is useful for applications where you want to run a device (i.e., fan or compressor) for a minimum amount of time after the input has been activated rather then using the deactivation delay. This ensures the fan or motor does not short cycle.
36
Page 42
If Adjust Temperature is chosen as the Type you will also be presented with the following options:
Decrease Heat Temp Allows you to program
the number of degrees that the heat set temperature will be adjusted by once an input has been activated. A positive number increases the heat set point and a negative number decreases the heat set point
Increase Cool Temp Allows you to program
the number of degrees that the cool set temperature will be adjusted by once an input has been activated. A positive number increases the cool set point and a negative number decreases the cool set point.
In both cases this oset will apply to the
set point temperature at the time of the activation of the input. As the system switches between program periods (i.e., occupied, unoccupied, etc) this oset will be maintained. Once the input has been switched back to the inactive state the set temperature will revert back to the normal limits.
Delete this Action Removes the congured
action.
37
Page 43
CONNECTING TO THE INTERNET
Connect your EMS Si to the Internet so you can control it from your own personalized, secure ecobee Web Portal, smartphone, or tablet.
From the Web Portal, you can:
Program, congure and control your EMS Si.
Control your EMS Si from anywhere you have
Internet access (including smartphones and tablets).
Use local weather data to maximize energy
savings.
Receive important alerts and reminders about
your heating and cooling system.
Note: To connect your system to your personalized ecobee Web Portal you must have a broadband Internet connection and a wireless 802.11 b/g/n (WiFi) home network.
38
Page 44
Setting Up WiFi and Obtaining a Registration Code
The EMS Si uses your home WiFi network to
connect to the Internet. First, enable WiFi on the EMS Si (see instructions to the right).
The EMS Si will display a list of available networks, along with an indication of the signal strength (the more bars, the better) and whether encryption is used.
If your home network is not listed, or if the signal strength is very low, try adjusting the antenna on your wireless router. If that doesn’t improve the signal, try moving your router closer to the EMS Si.
Once your network has been detected, select it from the list. If the network is encrypted, you will be asked to enter a password for that network. This is the password you created when the wireless router was rst set up.
After you provide the password, your EMS Si will automatically connect to the Internet. A chain link on the screen indicates you have established a connection with the ecobee web servers.
Write down the registration code as you will need it when conguring your Web Portal account. You can leave the code displayed on
the screen while you continue with the next step.
To set up WiFi:
From the Home screen, press MENU.
Select Register Thermostat.
Select Continue.
Select WiFi Settings.
Select WiFi Radio
Enabled.
Select your network from the list.
If prompted, enter your network password.
The EMS Si will automatically connect to the Internet and display a registration code.
Write down the registration code; you will need it in the next step.
39
Page 45
Having Trouble?
If you are having trouble connecting to the Internet or nding your WiFi network, you may need to congure your network parameters manually. See WiFi on page 52.
Conguring a Web Portal Account
After setting up WiFi on your EMS Si and obtaining the registration code, you need to congure your Web Portal account.
1. From a web browser on a PC, visit
www.ecobee.com and click on the LOGIN link.
2. Click REGISTER THERMOSTAT.
3. Click the EMS Si.
4. Click Create a new account.
(If you already have a Web Portal, click Register
to an existing account, enter your email address
and password, and proceed to step 6).
40
Page 46
5. Enter your address, contact, and user account information. Click Submit.
Your EMS Si is now registered. You can now monitor and control your EMS Si from the Web Portal or from your smartphone or tablet.
Re-registering the EMS Si
There are times when you may need to re­register your EMS Si. For example, if you are a new homeowner who has just moved to a home with an existing EMS Si. To re-register your EMS Si, reset the registration and redo the registration process.
To reset your registration:
From the Home screen, press MENU.
Select Settings Reset.
Select Reset Registration.
Conrm the reset by selecting Yes.
41
Page 47
USING YOUR EMS Si
The bright, easy-to-read screen on your EMS Si makes it simple to review and adjust the settings any time you want.
Adjusting the Temperature
You can easily adjust the temperature without changing the EMS Si’s programming by pressing the arrow keys when the Home screen is displayed.
Press to increase the temperature set point
by 1°F (0.5°C).
Press to decrease the temperature set
point by 1°F (0.5°C).
If the EMS Si is set to Auto mode, press to
select the Cool setting.
If the EMS Si is set to Auto mode, press to
select the Heat setting.
Once you’ve adjusted the temperature, the screen indicates that you are currently holding the set temperature rather than running a program.
The EMS Si will hold the new temperature for the duration you specied in the Hold Action option during the initial setup (see Hold Action on page
15) or until you press OK.
If you are using Auto mode, note that there is a minimum dierence allowed between heat and cool set temperatures. The system will prevent you from setting the temperatures to within these limits. See the EMS Si Installation Manual for information about conguring the minimum temperature dierence settings.
42
Page 48
System Mode
This menu sets your system to use heat, cool, or
auto mode:
Cool The system will turn on the air
conditioner when the current temperature rises above the set temperature.
Heat The system will turn on the heat when
the current temperature drops below the set temperature.
Auto The system is in Auto-changeover
mode and will activate the heating or cooling systems to keep your home within the desired range of set temperatures.
Auxiliary Heat Only The system will only
use the auxiliary or back-up heat source to maintain the heat set point temperature (only appears if auxiliary heat is congured).
O The system is o and will only display the
current temperature.
To change system mode:
From the Home screen, press MENU.
Select System Mode.
Select your temperature mode: Heat, Cool, Auto or O.
Fan
This menu displays the current furnace fan
setting:
On Forces the fan to run continuously,
regardless of the weekly schedule programming. The fan will also run if the system mode is O.
Auto Turns on the fan when the system is
heating or cooling your home, or to satisfy the minimum fan “on” time.
When you switch between Auto and ON in fan
control, the EMS Si will prompt you with the following:
To change fan settings:
From the Home screen, press MENU.
Select Fan.
Congure your fan settings.
43
Page 49
Hold 2 hours The fan will switch to this
setting but revert back to weekly schedule after 2 hours.
Hold 4 hours The fan will switch to this
setting but revert back to weekly schedule after 4 hours.
Indenite The fan will switch to this setting
and will only revert back if you do so manually .
Until Next Transition The fan will switch to
this setting but will revert back when the program switches to the next period.
Update Schedule The fan will update the
current schedule with this new fan setting.
After the fan mode is changed and you return
to the home screen, the EMS Si will indicate that it is in a Hold state. The temperature setting will also be set to Hold. Press OK to revert the fan mode back to the weekly schedule fan and temperature settings.
M inimum “On” Time Sets a minimum amount
of time per hour that the furnace fan will run. This improves air circulation and results in a more consistent temperature than with the Auto setting while being more cost-eective than the On setting.
44
Page 50
Weather Forecast
Displays the current outdoor temperature and weather conditions for your registered location.
Note that when you register, it’s important to select your location accurately, as ecobee will use your local weather data to optimize your heating and cooling. You must register your EMS Si for this feature to operate.
Cleaning the EMS Si
You can clean the EMS Si’s screen by spraying water or any mild, non-abrasive household cleaner on to a clean cloth. Wipe the surface of the screen with the dampened cloth.
Note: Do not spray any liquids directly onto your EMS Si.
To view the weather forecast:
From the Home screen, press MENU.
Select Weather Forecast.
Press OK to switch between the 4-day and 24-hour forecast.
45
Page 51
To congure personal Preferences:
From the Home screen, press MENU.
Select Settings
Preferences.
Adjust each option to your personal preferences.
CONFIGURING YOUR EMSSi
This section describes how congure the personal preferences, temperature settings, and operation of your EMS Si. There are three key steps:
Congure Personal Preferences
Set up Reminders and Alerts
Create your Weekly Schedule
Note: You can also congure your EMS Si from your personalized Web Portal. Simply open a web browser, go to ecobee.com, and log in.
Conguring Personal Preferences
The Preferences menu has settings for personalizing your EMS Si.
Name
You can customize the name of your EMS Si to suit your needs (i.e. Main Floor). This is useful if you have multiple systems or zones. You can view and edit your EMS Si name in the About menu on your EMS Si and also in your online Web Portal.
Temperature Display
Select Temperature Display to select Fahrenheit (°F) or Celsius (°C).
46
Page 52
Date and Time
Select Date & Time to:
Set the current date. Set the current time. Select a 12-hour or 24-hour time format. Select your time zone. Enable or disable daylight savings
adjustments.
If you are connected to the Internet, the time and date are programmed automatically.
Brightness
The color screen has adjustable backlight brightness. You can control the intensity when the screen is active (i.e., when you are pushing buttons) and when the display is in standby mode (idle screen).
Select Brightness to:
Set the Active brightness intensity.
Set the Standby (idle screen) brightness
intensity.
Set the minimum time the EMS Si will stay in
active brightness before switching to standby brightness.
Hold Action
Whenever you manually adjust the set temperature, the EMS Si will indicate you are in a “Hold” mode. You can select how long the EMS Si will hold the new temperature before reverting back to the regular program:
47
Page 53
Hold 2 hours
Hold 4 hours
Until next transition Thermostat will hold
temperature until the next program period.
Indenite Thermostat will hold temperature
until you press OK.
Update Schedule When you adjust the set
temperature, the system will update the temperature in the Weekly Schedule for the current period.
Ask Me Every time you adjust the set
temperature you will be asked which of the options you would like to choose.
Quick Save Settings
In Quick Save mode, your system will automatically increase (in cool mode) or decrease (in heat mode) the temperature set point by the pre-congured amount.
Quick Save mode can only be activated from the Web Portal or from the ecobee smartphone/ tablet application.
Access Control
You can protect your EMS Si so that certain features will require the user to enter a 4-digit access code. Use the arrow keys to highlight a number and then press OK. When you are done, select Save. The access control will be required once the idle screen is displayed.
To disable this feature, delete the number by selecting
multiple times.
48
Page 54
You can also congure the level of access control:
Restrict All Access Unauthorized users will
only be able to view the home screen and the weather information.
Restrict Details Access The code is required
to access the Details screen.
Restrict Program Access The code is
required to view and modify the EMS Si’s Weekly Schedule.
Restrict Vacation Access The code is
required to view and create a Vacation.
Restrict QuickSave The code is required to
exit QuickSave mode from the Web Portal.
In all cases, once the code is enabled, it will be required to access any of the list items in the Settings menu, with the exception of the About screen. Once a valid code has been entered on the EMS Si, access to restricted features will be allowed until the EMS Si backlight timer has expired.
Temperature Range
You can congure the EMS Si so only a specic heat and/or cool set point range is permitted.
Heat Temp Range Press or ▼ select the
maximum heat set point then press OK. Users will not be able to set the EMS Si to a temperature above this limit.
Cool Temp Range Press or ▼ to select the
minimum cool set point and then press OK. Users will not be able to set the EMS Si to a temperature below this limit.
49
Page 55
Recovery Options
Recovery options allow the EMS Si to learn how your heating and cooling system works, taking into account infrastructure, weather and historical operating performance so that your home is a comfortable temperature as soon as you walk in the door.
Smart Recovery Heat The EMS Si will start
heating at the optimum time to ensure the set point is reached at the programmed time.
Smart Recovery Cool The EMS Si will start
cooling at the optimum time to ensure the set point is reached at the programmed time.
Random Start Heat Programming a time
in this section will produce a random delay when there is call for heat. In applications with multiple heating systems, this prevents all the systems from activating at the same time (thus creating a peak power demand). Press or to select a delay time and then press OK.
Random Start Cool Programming a time
in this section will produce a random delay when there is call for cooling. In applications with multiple cooling systems, this prevents all systems from activating at the same time, (thus creating a peak power demand). Press or to select a delay time and then press OK.
Utility CPP Setting
This section is only applicable if your utility company is running a Critical Peak Pricing program that you have agreed to be a part of. Contact your local electrical utility company for information about programs in your area.
50
Page 56
CPP Response
Your utility may send voluntary events to your EMS Si. You can choose to Always Accept these events. In which case, you would just be notied that an event is in progress. Or if you choose Ask
Me, when the Utility issues an event, you will be
asked if you want to participate.
If you do not acknowledge the event prior to the start, the system will default to yes.
Preferred Strategy
During a Critical Peak Pricing event the Utility may select an energy saving strategy, or allow you to use your preferred strategy. Select from one of the options as your preferred energy saving strategy to be used during Critical Peal Pricing events.
Absolute Temperature Set a specic heat
and cool set point to be used when an event is initiated by the Utility company. If the set point at the time of the event is more favorable (lower in heat mode or higher in cool mode) than what you have programmed, the EMS Si will use the more favorable set point for the duration of the event.
Relative Temperature Program a
temperature set back (heat) or set forward (cool) from your existing set point. For example, if you program a 4 °F set forward, and your current cool set point is 76 °F, during an event your EMS Si set point will change to 80 °F until the event has expired.
System O If this option is selected, the EMS
Si will turn o heating and cooling for the duration of this event.
51
Page 57
To congure WiFi manually:
From the Home screen, press MENU.
Select WiFi.
Adjust the network options for your home network.
Duty Cycle This option allows you to
program the maximum amount of time the system will run during a 1 hour period. For example, if you select 30%, the air conditioner will run for a maximum of 18 (0.3 x 60) minutes regardless of whether the set point has been met. 0% essentially turns the system o, whereas 100% runs the system at full capacity.
WiFi
The EMS Si supports WiFi 802.11 b/g/n. Use the Advanced Conguration option in the WiFi menu to congure your network parameters. Choose the network from the list or manually add a new one (i.e. if your network does not broadcast its SSID).
You will then be able to view and congure the following network parameters:
DHCP (select Disabled to use a static IP
Address; if unsure, leave DHCP Enabled)
SSID
Encryption (WEP, WEP128, WPA, or WPA2)
Password (if encryption is used)
WiFi Channel
IP Address and IP Subnet
Gateway
Primary and Secondary DNS
If you need to specify your EMS Si’s MAC address in your router’s conguration, you can obtain it from the About menu.
52
Page 58
Creating Your Weekly Schedule
Your heating and cooling needs change depending on the time of day and day of the week. For example, if there’s no one in the house during the workday you might want to let the temperature go up in the summer, to reduce energy used by the air conditioning system, and down in the winter, to reduce heating energy.
By default, the EMS Si includes two congurable periods:
Occupied Represents the period when the
building or area is occupied.
Unoccupied Represents the period when the
building or area is unoccupied.
The EMS Si learns how your building’s heating and cooling equipment perform. Intelligent algorithms combine weather data, your HVAC equipment run times and occupancy schedules to optimize performance and maximize energy savings.
To view your weekly schedule:
From the Home screen, press MENU.
Select Weekly Schedule.
Your weekly schedule is shown on the screen.
To edit your weekly schedule:
Display your Weekly
Schedule.
Press OK.
Select the Day.
Select the Time, Heat or
Cool Setting.
or to adjust the
Press the value. Press
toggle between columns.
Press OK.
Select Save and Continue.
Select any other days of the week that will also use the new settings. Use the navigation keys to switch between days and press OK to select a day.
Select Continue. The new schedule is displayed on the screen.
◀ or ▶ to
53
Page 59
To add a new period:
Display the schedule for a day and select Add New.
Select Create New Item.
Enter a name for the new period and select Save.
If your house is in-use during this period, select
Yes ; otherwise select No.
Select Enable.
Select the new time and press OK.
The new period is added.
If your schedule changes, you can quickly and easily update the EMS Si settings on the device itself or online through your Web Portal.
Using the Weekly Schedule Editor
The Weekly Schedule editor lets you to set specic times, temperatures and furnace fan settings for each day of the week.
If your system is enabled for auto change-over mode, the heat and cool set temperatures will automatically be adjusted to ensure a minimum dierence.
Adding New Periods
To accommodate for your varying schedule you can add additional program periods in your week. For example if you come home for lunch during the week or want dierent settings for the weekend, you would simply add one of the existing periods at the allocated time and day or create a completely new one.
Disable a Period
To disable a period entirely, select the period’s
Time and then select Disable.
54
Page 60
Scheduling a Calendar Event
The EMS Si’s Calendar Event feature helps you conserve energy while you are away for extended periods of time. It also ensures your building is comfortable when you return.
A calendar event includes a name, start date and time, as well as the end date and time. You can enter any number of uniquely named vacations. Other vacation features to choose from include:
ecobee optimize
Select Yes to have the EMS Si automatically set your Heat Temperature, Cool Temperature, System Mode and Furnace Fan settings to maximize energy conservation.
Select No to manually congure Heat Temperature, Cool Temperature and Fan settings. These settings will be remembered the next time you create a calendar event.
Is Occupied
Select Yes, if during the calendar event the building or area will be occupied.
Heat Temperature
Programs the set temperature when the system is in Heat mode (i.e., when the furnace is on). Set a lower temperature to save energy.
To schedule a calendar event:
From the Home screen, press MENU.
Select Calendar Events.
Select Add Event.
Enter a Name.
Enter the Start and End dates and times of your calendar event.
Cool Temperature
Programs the set temperature when the system is in Cool mode (i.e., when the air conditioner is on). Set a higher temperature to save energy. You can also choose to turn o your cooling system while you are away to save more energy.
55
Page 61
Fan
Toggles the fan setting between ON and Auto.
ON The fan runs all the time regardless of
programming or if there is a call for heat or cool. The fan will also run if the System Mode is OFF.
Auto This option turns the furnace fan on but
only when the system is heating or cooling your home, or to satisfy the minimum fan run time as programmed.
Fan Min On Time This feature allows you to
determine a minimum time per hour that the furnace fan will run. It results in increased air circulation and a more consistent temperature within the home, and is more cost eective than choosing the ON fan setting.
In either mode, the EMS Si will ensure that when your calendar event ends, the EMS Si will revert to the regular settings.
Note: If you were running your regular program prior to the start of your calendar, on your return, the EMS Si will restore your building to those settings. If you were in Hold mode prior to the start of your calendar event, the EMS Si will restore the home to whatever the set temperature was just prior to your calendar event.
56
Page 62
Delete Event
You can delete individual or all calendar events:
To remove an individual vacation event,
display the details about the vacation event, then select Delete Event Yes .
To remove all vacation events, display the
Calendar Event menu and select Delete All
Yes.
3-YEAR LIMITED WARRANTY
ecobee warrants that for a period of three (3) years from the date of purchase by the consumer (“Customer”), the ecobee EMS Si (the “Product”) shall be free of defects in materials and workmanship under normal use and service. During the warranty period, ecobee shall, at its option, repair or replace any defective Products, at no charge. Any replacement and/ or repaired device are warranted for the remainder of the original warranty or ninety (90) days, whichever is longer.
If the product is defective, call Customer Service at 1-877-932-6233. ecobee will make the determination whether a replacement product can be sent to you or whether the product should be returned to the following address: ecobee Customer Service, 333 Adelaide Street West, 6th Fl., Toronto, ON M5V 1R5, Canada. In the event of a failure of a Product, Customer may:
(a) if Customer did not purchase the Product directly from ecobee, contact the third party contractor from whom the Product was purchased to obtain an equivalent replacement product, provided the contractor determines that the returned Product is defective and Customer is otherwise eligible to receive a replacement product;
(b) contact ecobee directly for service assistance at
57
Page 63
1-877-932-6233 and ecobee will make the determination whether an advance equivalent replacement Product can be sent to Customer with return shipping supplies (in which case a hold shall be put on Customer’s credit card for the value of the replacement Product until ecobee has received the defective Product). Product should be returned to the following address: ecobee Customer Service, 333 Adelaide Street West, 6th Fl., Toronto, ON M5V 1R5, Canada. If the returned Product is found by ecobee to be defective and Customer is otherwise eligible to receive a replacement product, no amount shall be charged to Customer’s credit card; or
(c) ship the defective Product directly to ecobee, in which case Customer shall contact ecobee directly at 1-877-932-6233, so ecobee can make the required shipping arrangements. Upon receipt of the defective Product, ecobee will ship an equivalent replacement product to Customer, provided the returned Product is found by ecobee to be defective and Customer is otherwise eligible to receive a replacement product.
This warranty does not cover removal or reinstallation costs and shall not apply if the damages were found to be caused by something other than defects in materials or workmanship, including without limitation, if the Product:
was operated/stored in abnormal use or maintenance conditions;
is repaired, modied or altered, unless ecobee expressly
authorizes such repair, modication or alteration in writing;
was subject to abuse, neglect, electrical fault, improper handling, accident or acts
of nature;
was not installed by a licensed Heating Ventilating and Air Conditioning (HVAC)
contractor; or
was installed improperly.
ecobee’s sole responsibility shall be to repair or replace the Product within the terms stated above. ECOBEE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some US states and Canadian provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
ecobee’s responsibility for malfunctions and deects in materials and workmanship is limited to repair and replacement as set forth in this warranty statement. All express and implied warranties for the product, including but not limited to any implied warranties and conditions of merchantability and tness for a particular purpose, are limited to the three-year duration of this limited warranty. No warranties, whether express or implied, will apply after the limited warranty period has expired. Some US states and Canadian provinces do not allow limitations on how long an implied
58
Page 64
warranty lasts, so this limitation may not apply.
ecobee neither assumes responsibility for nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product.
This warranty gives you specic rights, and you may also have other rights which vary from jurisdiction to jurisdiction. If you have any questions regarding this warranty, please write ecobee Customer Service, 333 Adelaide Street West, 6th Floor, Toronto, Ontario M5V 1R5, Canada.
END-USER SOFTWARE LICENSE AGREEMENT
Please read the following carefully, as this end user software license agreement (“EULA”) is a legal agreement between ecobee Inc., having its place of business at 333 Adelaide Street West, 6th oor, Toronto, ON, M5V 1R5 Canada, (“ecobee”) and you (either an individual or the entity that you represent and referred to in this agreement as “licensee”), The original purchaser of ecobee product (The “product” or “products”) embedded with ecobee proprietary software (the “software”) concerning licensee’s limited access to and use of the software. By using the product (including the software embedded in the product), you are indicating your acceptance of, and you agree to be bound by the terms and conditions of this EULA which shall govern your access and use of the software. If you do not agree with the terms and conditions of this EULA, your access to and use of the software will not be permitted and you may, within fourteen days of the date of your purchase if the ecobee product, return the software together with the product in its original packaging and sale condition to: (a) ecobee if you have purchased the ecobee product directly from ecobee or; (b) to an ecobee authorized reseller or distributor if you have purchased the ecobee product from such entities, and ecobee or its authorized reseller or distributor as applicable shall provide a ll refund of the purchase price paid within fourteen days of its receipt of the return.
In consideration of the license fees paid by LICENSEE as part of the purchase price of the ecobee Product and the mutual covenants contained herein and for other good and valuable consideration, the receipt and suciency of which are hereby acknowledged, ecobee and LICENSEE agree as follows:
1. Denitions: For the purpose of this EULA, the following terms shall have the meanings hereinafter provided:
“ecobee Web Portal” means the web site portal operated by ecobee to provide certain services and functionality to registered users of ecobee Products.
“Error” means any program defect, error, bug or other failure of all or part of the Software that results in the Software not conforming to, or performing in
59
Page 65
accordance with, its published specications.
“Software” means ecobee’s computer software program, which enables data upload and download to and from the ecobee Web Portal using an ecobee Product, including any Software Updates.
“User Manual” means the ecobee User Manual provided together with the Product and Software.
“Software Updates” means updates or patches to the Software, including updates intended to correct Errors and which may include enhancements and/ore additional features to the Software, as may be provided or released by ecobee from time to time to all of its customers at no charge.
2. Ownership of Software: LICENSEE acknowledges and agrees that, save and except for the Software license explicitly granted by the EULA, all right, title and interest in and to the Software and the User Manual is the sole and exclusive property of ecobee and/or its licensors), as the case may be. ecobee reserves all rights not expressly granted to LICENSEE hereunder, and for greater certa inty, ecob ee shall retain all intellectual property and other proprietary rights in and to the Software and the User Manual. Nothing in this EULA shall, or shall be deemed or construed to, assign, transfer or convey to LICENSEE any title, rights or interest in or to any intellectual property, including in or to the Software or User Manual, other than the licenses specically and expressly granted herein.
3. Grant of Limited License: Upon LICENSEE’s use of the Product (and corresponding acceptance of the terms and conditions of this EULA), ecobee hereby grants to LICENSEE a limited, non-exclusive, personal, perpetual, non-transferable and revocable license to use the Software embedded in the Product as and to the extent described in this EULA for as long as LICENSEE complies with the terms and condition of this EULA. ecobee reserves all rights not expressly granted to LICENSEE. For certainty, this EULA does not apply to or govern LICENSEE’s use of or access to the ecobee Web Portal or the ecobee Product, which are each governed by and subject to separate terms and conditions.
4. Permitted Use: Pursuant to the Software license granted to LICENSEE under this EULA, LICENSEE shall be permitted to: (a) use the Software embedded in the Produ ct for the purposes of using the Product only as intended and contemplated by the User Manual, provided that the Software may only be used for its personal and private use in connection with the use of the Product; and (b) use the User Manual provided by ecobee solely as is necessary to operate and use the Software and ecobee Product as and to the extent permitted thereunder and under this EULA.
5. License Transferable: This EULA shall be binding upon and shall ensure to the benet of and be enforceable by each of the parties, their respective successors and permitted assigns. LICENSEE may assign this EULA without the prior consent of ecobee. ecobee may assign this EULA without the consent of LICENSEE at any time.
60
Page 66
6. Copy Restrictions: Unauthorized copying or distribution of Software or the User
Manual is expressly prohibited. LICENSEE may make a reasonable number of copies of the User Manual to the extent reasonably required for its use of the Software and Product as permitted by this EULA; provided that LICENSEE may not use the User Manual separately from the Product or Software or for any purpose other than as contemplated herein.
7. Use Restrictions: LICENSEE may not: (a) modify, adapt or otherwise change the
Software or in any way remove the Software from the Product for any reason or use the Software separately from the Product for any reason or purpose; (b) to the maximum extent permitted to be restricted by applicable law, reverse engineer, decompile, disassemble, or otherwise in any manner deconstruct all or any part of the Software; (c) create derivative works based on the Software or the User Manual; (d) except as expressly permitted by the EULA, provide, disclose, sublicense, distribute, transfer, assign or otherwise permit any third party to access, use, read or otherwise gain access to the Software or User Manual (the Software and User Manual being the condential information of ecobee); or (e) use Software to access or in conjunction with any other thermostat monitoring services or products of any ecobee competitor.
8. Support: ecobee may in its discretion, without any obligation to do so and subject
to the limitations of this EULA, provide LICENSEE with help-desk telephone support concerning LICENSEE’s use of the SOFTWARE to the extent provided for in the Product Terms of Sale in connection with purchase and sale of the Product and the Terms of Service entered into by you and ecobee, if any, in connection with the thermostat monitoring and data management services provided by ecobee in connection with the Product. Refer to the Product Terms of Sale and/or the Terms of Service associated with the Product and related services for further details on Software and Product support.
9. Relief: LICENSEE agrees that damages would not be an adequate remedy for any
breach of this EULA aecting or related to a breach or misappropriation of ecobee’ (or its or its third party licensors’) intellectual property rights in and to the Software and User Manual. LICENSEE, and nothing in this EULA, shall interfere with, delay, obstruct, or prevent ecobee from taking, or require ecobee to take, any steps prior to taking action to seek an interim and interlocutory equitable remedy on notice or ex parte to enforce any provision herein to protect its rights concerning the Software or other intellectual or proprietary rights. LICENSEE agrees not to contest, object to, or otherwise oppose an application for equitable relief by ecobee in such circumstances and LICENSEE waives any and all immunities from any equitable relief to which it may be entitled. Any such relief or remedy shall not be exclusive, but shall be in addition to all other available legal or equitable remedies. LICENSEE agrees that the provisions of this Section are fair and reasonable and are necessary to protect ecobee’ intellectual property rights.
10. Termination: This EULA is eective until and unless terminated. Subject to
Section 13, this EULA will terminate automatically if LICENSEE fails to comply with
61
Page 67
any provision of the License. If LICENSEE is a business entity or other entity, any failure to comply with the terms and condition of this EULA by any individual employed or engaged by such entity will be deemed a failure to comply by LICENSEE. Upon any termination, LICENSEE shall destroy all copies of Software and User Manual.
11. Warranty: (a)ecobee shall provide its standard Product and Software limited warranty statement (“Customer Warranty”), which equally applies to the Software embedded in the Product, and which is incorporated by reference herein, with the Product for your benefit only. In the event of an Error in connection with the Software, refer to the Customer Warranty and Terms of Sale provided with the Product for further detail. (b) EXCEPT FOR THE REPRESENTATIONS, WARRANTIES, AND COVENANTS EXPRESSLY CONTAINED IN THIS EULA, THE PRODUCT TERMS OF SALE AND THE PRODUCT WARRANTY, THE SOFTWARE AND SOFTWARE DOCUMENTATION AND ANY SUPPORT IS PROVIDED ON AN “AS IS” BASIS, AND THERE ARE NO OTHER REPRESENTATIONS, WARRANTIES, COVENANTS, OR CONDITIONS, EXPRESS OR IMPLIED (INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABLE QUALITY OR FITNESS FOR A PARTICULAR PURPOSE AND THOSE ARISING BY STATUTE OR OTHERWISE IN LAW OR FROM A COURSE OF DEALING OR USAGE OF TRADE), INCLUDING, BUT NOT LIMITED TO, NON-INFRINGEMENT, CORRECTNESS, FUNCTIONALITY, RELIABILITY, ACCURACY, CURRENTNESS, OPERATION, USE OR THE RESULTS OF THE USE BY LICENSEE, THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE (OR THAT ALL ERRORS CAN OR WILL BE CORRECTED) OR THAT THE SOFTWARE OR SOFTWARE DOCUMENTATION WILL MEET LICENSEE’S REQUIREMENTS, ALL OF WHICH ARE EXPRESSLY DENIED AND DISCLAIMED TO THE MAXIMUM EXTENT PERMITTED BY LAW. SOME JURISDICTIONS DO NOT PERMIT LIMITATIONS ON OR EXCLUSIONS OF CERTAIN IMPLIED WARRANTIES, OR THE EXCLUSION OR LIMITATION OF CERTAIN DAMAGES; THEREFORE THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU IN CERTAIN CIRCUMSTANCES. ecobee DISCLAIMS AND SHALL HAVE NO LIABILITY TO LICENSEE FOR ANY AND ALL ACTS OF THIRD PARTIES. NO OTHER PERSON IS AUTHORIZED TO EXTEND, VARY OR TRANSFER ANY PROVIDED WARRANTY ON BEHALF OF ecobee. THE ENTIRE RISK AS TO THE RESULTS AND PERFORMANCE AND USE OF THE SOFTWARE, SOFTWARE DOCUMENTATION AND ANY P ROVIDED SUPPORT IS ASSUMED BY LICENSEE.
12. Limitation: IN NO EVENT AND TO THE MAXIMUM EXTENT PERMITTED UNDER APPLICABLE LAW SHALL ECOBEE, ITS SHARE-HOLDERS, AFFILIATES, CONTRACTORS, SUPPLIERS AND AGENTS AND THEIR RESPECTIVE DIRECTORS, OFFICERS AND EMPLOYEES (COLLECTIVELY THE “ECOBEE PARTIES”) BE LIABLE TO LICENSEE OR ANY THIRD PARTY FOR ANY INDIRECT, INCIDENTAL, EXEMPLARY, SPECIAL, PUNITIVE OR CONSEQUENTIAL DAMAGES (INCLUDING WITH RESPECT TO LOSS OF, OR DAMAGE TO, DATA OR COMPUTER SYSTEMS OR RELIANCE ON ANY DATA DERIVED FROM LICENSEE’S USE OF THE SOFTWARE, OR LOSS OF REVENUE OR PROFIT OR OTHER
62
Page 68
ECONOMIC LOSS) OF ANY KIND OR NATURE WHATSOEVER SUFFERED BY LICENSEE OR ANY THIRD PARTY HOWSOEVER CAUSED AND WHETHER RESULTING FROM THE USE OF OR INABILITY TO USE THE SOFTWARE OR OTHERWISE (INCLUDING AS A RESULT OF OR DUE TO USE OF OR RELIANCE ON THE SOFTWARE AND/OR ecobee WEB PORTAL) AND REGARDLESS OF THE FORM OR CAUSE OF ACTION, EVEN IF SUCH DAMAGES ARE FORESEEABLE OR ecobee HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. ECOBEE PARTIES’ TOTAL LIABILITY AND OBLIGATION TO LICENSEE, IN THE AGGREGATE FOR ANY AND ALL CLAIMS ARISING OUT OF OR IN ANY CONNECTION WITH THIS EULA, THE TERMS OF SALE IN CONNECTION WITH YOUR PURCHASE OF THE PRODUCT AND YOUR USE OF THE SOFTWARE AND PRODUCT, WITH RESPECT TO ANY EXPENSE, DAMAGE, LOSS, INJURY, OR LIABILITY OF ANY KIND, REGARDLESS OF THE FORM OF ACTION OR THEORY OF LIABILIT Y (INCLUDING FOR BREACH OF CONTRACT, TORT, NEGLIGENCE, BY STATUTE OR OTHERWISE) SHALL BE LIMITED TO THE ACTUAL DIRECT DAMAGES SUFFERED AND SHALL NOT EXCEED AN AMOUNT THAT IS EQUIVALENT TO THE PURCHASE PRICE OF THE ecobee PRODUCT ACTUALLY PAID BY LICENSEE. THIS SECTION SHALL SURVIVE A FUNDAMENTAL BREACH OR BREACHES AND/OR FAILURE OF THE ESSENTIAL PURPOSE OF THE AGREEMENT.
13. Survival: The parties acknowledge and agree that the provisions of Sections 2, 6,
7, 9, 11(b), 12, 13, 14, 15, 16 and 17 shall survive any termination of this EULA for any reason.
14. English Language: The parties declare that they have required that this agreem ent
and all documents related hereto, either present or future, be drawn up in the English l anguage only. Les parties déclarent par les présentes qu’elles exigent que cette entente et tous les documents y aérents, soit pour le présent ou le futur, soient rédigés en langue anglaise seulement.
15. Jurisdiction: This EULA shall be exclusively governed by, construed and interpreted
in accordance with the laws of the Province of Ontario, Canada. For the purpose of all legal proceedings this EULA shall be deemed to have been performed in the Province of Ontario, Canada and the parties expressly conrm that the law of the Province of Ontario is the proper law. If Customer is located in a jurisdiction other than Canada, the parties agree that neither the United Nations Convention of the International Sale of Goods or the (U.S.) Uniform Computer Information Transactions Act shall apply to this EULA. The parties irrevocably attorn to the non­exclusive jurisdiction of the Courts of the Province of Ontario in respect of all matters and disputes arising hereunder.
16. Export Law Assurances: LICENSEE acknowledges that the Software may be s ubject
to export and import control laws, and agrees to comply fully with those laws in connection with the Software.
17. General Provisions: No delay or omission by ecobee to exercise any right
or power it has under this EULA or to object to the failure of any covenant of
63
Page 69
LICENSEE to be performed in a timely and complete manner, shall impair any such right or power or be construed as a waiver of any succeeding breach or any other covenant. Any waivers by ecobee must be in writing and signed by an authorized representative of ecobee. If any provision of this EULA is held by a court of competent jurisdiction to be invalid or unenforceable in any respect, then the remaining provisions of this EULA, or the application of such provisions to persons or circumstances other than those as to which it is invalid or unenforceable shall not be aected thereby, and each such provision of this EULA shall be valid and enforceable to the extent granted by law. The EULA constitutes the entire agreement between the parties as it relates to the license and use of the Software and User Manual and the subject matter of this EULA and supersedes all prior or contemporaneous agreements, negotiations, representations and proposals, written or oral between ecobee and LICENSEE. The EULA may only be amended or supplemented by written agreement executed by each of the parties.
64
Page 70
656667
Page 71
Page 72
Page 73
68
Loading...