8
Dehumidifier has reached its The dehumidifier automatically turns off when either
preset level or tank is full. condition occurs. Change to a lower humidity setting
or empty the tank and replace properly.
Tank is not in the The tank must be in place and securely seated for the
proper position. dehumidifier to operate.
Power failure. There is a protective time delay (up to 3 minutes) to
prevent tripping of the compressor overload. For this
reason, the unit may not start normal dehumidifying
for 3 minutes after it is turned back on.
Did not allow enough time When first installed, allow at least 24 hours to maintain
to remove the moisture. the desired dryness.
Airflow is restricted. Make sure there are no curtains, blinds or furniture
blocking the front or back of the dehumidifier. See the
Dirty filter. See the Care and Cleaning section.
The Humidity Control may For drier air, turn the dial and set to a lower percent
not be set low enough.
Doors and windows may not Check all doors, windows and other openings
be closed tightly. are securely closed.
Tumble dryer may be Install the dehumidifier away from the tumble dryer
blowing moisture-laden
The tumble dryer should be vented to the outside.
air into the room.
Room temperature Moisture removal is best at higher room
temperatures.
is too low. Lower room temperatures will reduce the moisture
removal rate. Models are designed to be operated at
temperatures above 5°C.
Area to be dehumidified The capacity of your dehumidifier may not be adequate.
is too large.
Doors and windows are open. Close all doors and windows to the outside.
Dehumidifier has been recently This is normal. Frost will usually disappear
turned on, or room temperature within 60 minutes. See the Automatic Defrost section.
is below 5°C.
The compressor will turn off
This is normal. Wait approximately 3 minutes and set th
e
and the fan will automatically fan as desired.
continue to run for
approximately 3 minutes at a
fixed setting.
There is a sound created when the
fan runs that sounds like the wind.
This is normal.
Hose connection may be loose.
Check the hose connection. See the Removing Collected
Intend to use the to Disconnect the hose if using the to collect water.
collect water, but a hose
See the Removing Collected Water section.
is attached.
TROUBLESHOOTING
Problem
Dehumidifier
does not start
Possible Causes
What To Do
Choosing a Location section.
value (%) or at CON (continuous) for maximum
dehumidification.
Watersection.
Dehumidifier does not
dry the air as it should
Dehumidifier runs
too much
Frost appears on
the coils
Controls cannot be set
Fan noise
Water on floor