Microprocessor-controlled
100~699℃(212~1290℉),Adjustment
OFF & 1~240min adjustment
Temperature of sleep mode
Temperature lock function
Replacement soldering iron
SS-256 LCD Smart Soldering Station
Thank you for purchasing the SS-256 LCD Smart Soldering Iron
Station. Please read this manual before operating the SS-256.
Please store the manual in a safe, easil y accessibl e plac e for future
reference.
Features
Large screen with backlight, LCD contrast and brightness are
adjustable.
Designed with functional manual and shuffle knob for easy setting, more
convenient and user friendly.
Comes with high end quad-wire heating element for heat fast recovery.
Microprocessor controlled provide best performance and accurate
temperature control.
Temperature calibration function.
Auto sleep and wake up function, system lock, tip calibration and low
consumption.
3 data memories store and recall frequently used temperature values.
Built-in DC 5V/1A USB port for power supply.
Complies with CE and ESD standard, conform to RoHS.
Comes with UL Certified Wires.
Silicone handpiece cord wire heat-resistant up to 200°C.
Resettable fuse protection design.
Packing List
Please check the contents of the soldering station package and confirm
that all the items listed below are included.
Soldering Station………..……………1
Iron Stand(with cleaning sponge).1
Soldering Iron…………………………1
Power Cord…………………..….……1
Alligator Clip Grounding Wire….…....1
User’s Manual……………...…………1
Specifications
Model No.
Input Voltage (ACV)
-256E
220~240V
LCD Display function description
1. Current beep on or off 2. Temperature lock
3. Current sleep mode 4.
Power display
5. T emperature unit
6. Current Temperature
7. T emperature memory setting
Setting up & operating the soldering station
Start to use
Turn on the soldering station, LCD screen will display main menu (see fig.1)
after three seconds, last set temperature will display. (see fig.2)
Fig.1 Fig.2
Temperature setting
In the main menu, rotate around the shuffle knob in clockwise directi on to
increase temperature, counter clockwise direction to decrease temperature
Temperature memory choose
In the main menu, press the center of shuffle knob,
CH1/CH2/CH3 will
twinkling (se e fig.3), rotate around the shuffle knob to choose the
temperature needed, press the center of shuffle knob again to save.
Plug
Tip-to-ground resistance
Soldering
Sponge
B
℃/392℉
2Ω/≦2mV
℉~896℉
C
Fig.3
Function setting menu
Press 3 seconds of shuffle knob into the function setting menu. (see fig.4)
The first function setting is TEMP , rotate around the shuffle knob in
clockwise direction can be converted into the other function setting.
Function order of priority :
TEMP→UNIT→SLP→BEEP→LIGH→CODE→EXIT→back to TEMP
Press shuffle knob again, choose the function needed.
Fig.4
TEMP:Temperature memory setting (Fig.5)
Choose the “TEMP” function setting. Press knob into channel selection
mode. Rotate around the shuffle knob to choose CH1/CH2/CH3, press
knob again to the temperature setting , rotate around the shuffle knob in
clockwise direction to increase temperature, counter clockwise direction to
decrease temperature. Press knob to the next menu, rotate around the
shuffle knob and choose the “ Exit” save the temperature and exit the
menu.
Fig.5
Fahrenheit and Centigrade Selection (Fig.6)
Choose the “UNIT” function setting. Press knob into temperature unit
selection mode, rotate around the knob , select “Fahrenheit” or “Centigrade”
unit, Press knob to the next menu, rotate around the shuffle knob and
choose the “ Exit” save the temperature unit and exit the menu.
USB port
Fig.6

SLP:Auto sleep mode setting (Fig.7)
1 Choose the “SLP” function setting. Press knob into sleep selection mode.
rotate around the shuffle knob to setting, sleep timer is adjustable from
1~240 minutes or setting “OFF” stop sleep mode activate ,after
setting ,press knob to the next menu, rotate around the shuffle knob and
choose the “ Exit” save and exit the menu.
In sleep mode ,the heater temperature will down to the 200℃, If need to
2.
start soldering, press knob to wake up, temperature will rise to setting
temperature.
Fig.7
BEEP:Beep setting (Fig.8)
Choose the “BEEP” function setting. Press knob into beep selection mode.
rotate around the shuffle knob to setting switch “ON” or “OFF” mode ,after
setting ,press knob to the next menu, rotate around the shuffle knob and
choose the “ Exit” save and exit the menu.
When beep is setting “ON” mode, press knob will have key beep.
and record tip real temperature, enter the real temperature in the “CALl”
state ,s ol deri ng i ron station will calculat e tem perat ure.
3 CALI. Status description
3.1. When “CALI” status display “- - -“(see Fig 13),it means temperature
have not calibration.
Fig 13
3.2. When “CALI” status display “H” or “HH” (see Fig 14.),it means “Real
Temp.” has calibrated and increase temperature.
For example :“set.Temp”is 350℃, "Real Te mp.”is 320℃, after temperature
calibration as Fig 12.,temperature will rise to 350℃.
3.3.When “CALI” status display “L” or “LL” (see Fig 15.),it means “Real
Temp.” has calibrated and decrease temperature.
Fig.8
LIGH:LCD screen brightness adjustment (Fig.9)
Choose the “LIGH” function setting. Press knob into LCD screen
brightness adjustment mode. rotate around the shuffle knob to setting
brightness 0~9 ,after setting ,press knob to the next menu, rotate around
the shuffle knob and choose the “ Exit” save and exit the menu.
Fig.9
CODE: Temperature passcode setting (Fig.10)
1. Choose the “CODE” f unct i on setti ng. P ress knob int o Passcode
selection mode. rotate around the shuffle knob input the old code and new
code ,after setting ,press knob to the next menu, rotate around the shuffle
knob and choose the “ Exit” save and exit the menu.
2. In the main menu, press 3 seconds of shuffle knob, input the passcode,
into the function setting menu, now can start to do any setting.
3. Cancel passcode : In the main menu, press 3 seconds of shuffle knob,
input the passcode, into the function setting menu, follow the
procedure 1 reset new code “000” .
4. After setting, press knob to the next menu, choose the “Exit” save the
setting and exit the menu.
CAUTION: Factory initial setting is “000”, this code without lock
function.
Fig.10
EXIT:Save and Exit (Fig.11)
Fig.11
Temperature Calibration Set
The soldering iron should be recalibrated after changing the iron, or
replacing the heating element or tip.
1 In the main menu, press knob for 6 seconds into the “CALI ” mode (see
Fig.12), rotate around the shuffle knob and input the real temperature.
Press knob to save the temperature and exit back to the main menu.
3.4. When “CALI” status display “HHH” (see Fig 16.),it means “Real Temp.”
has calibrated to max. temperature, can not increase anymore, but it can
decrease temperature.
3.5 When “CALI” status display “LLL” (see Fig 17.),it means “Real Temp.”
has calibrated to minimum temperature, can not decrease anymore, but it
can increase temperature.
Fig 16 Fig 17
Reset
In the main menu, press knob for 9 seconds into the “REST ” mode, initial
setting is “NO” (see Fig18), rotate around the knob , choose “YES” (see
Fig 13) and press knob confirm it, Press knob to save and exit back to the
main menu.
Fig 18
Fig 14 Fig 15
Passcode forgot and reset
If forgot passcode, turn off the power, press knob and power in the same
time,), input passcode “888” , the soldering iron station will reset passcode
become”000”.
For further more detailed information, please visit Pro’skit
website http://www.prokits.com.tw
or scan the QR code
Fig.12
2 Calibrating the iron temperature
Setting the sol deri ng iron station temperature to 350℃, when the
temperature stabilizes, use soldering iron tip thermometer measurement
PROKIT’S INDUSTRIES CO., LTD.
http://www.prokits.com.tw
E-mail:pk@mail.prokits.com.tw
©2020 Prokit’s Industries Co., Ltd. All rights reserved 2020001