ECHOMAX RTE Installation And Operation Manual

Power
To turn the unit on press the “Power” button, the RED power indicator will illuminate continuously. To turn the unit off press the “Power” button, the RED power indicator will turn off.
Internal Audible Alarm
Pressing the “Alarm” button will toggle the internal audible alarm on and off. When the internal audible alarm is enabled the BLUE alarm indicator is turned off. When the internal audible alarm is disabled the BLUE alarm indicator is illuminated. The status of the internal audible alarm is stored in NVM and is retained for use after power cycling the unit.
Note: the factory default setting is internal alarm enabled.
RTE Active Waterproof Control Box
INSTALLATION AND OPERATION
Sensitivity Level Tone Frequency ms of Activity
in 3 sec
1 (least sensitive) 500Hz 250
2 550Hz 200 3 600Hz 150
Connectivity
The waterproof control box has been designed for owner installation. If, however, you do not feel confident seek the help of a professional. Select a position for the backing plate on a bulkhead or steering consul and drill or cut a 57mm hole as shown on the template supplied overleaf making sure that there are no existing wires behind the proposed installation. Fit cable glands to the rear section and feed the RTE, power and extension wiring through them remembering to keep the two cable glands at the top so they are level with the PCB connectors. If no extension alarm is being fitted blank the single lower hole with the blanking plug and gasket provided. For ease of attaching the wiring as shown on page two use thin nose pliers to remove and replace the green male terminal connectors after the wires have been firmly attached. Only leave sufficient inner cables so that the back plate can be fixed in position. Gently tighten waterproof glands. Check that the O ring is in place and press the front of the control to the backing plate until the two pop together and are flush. Attach the front section to the back plate using the four Allen screws and the Allen key provided.
A
udible Alarm Sensitivity
The sensitivity of the audible alarm is user adjustable and can be set to 1 of 7 different levels. The sensitivity setting will determine the amount of RADAR activity, measured in milliseconds within a 3 second window, required to sound the audible alarm. To enter into the alarm sensitivity adjustment mode, press and hold the“Alarm” button for 5 seconds until the internal s
peaker emits a tone. Subsequent presses of the “Alarm” button will increase the sensitivity level, which is indicated by the pitch of the tone emitted by the internal speaker, refer to Table 1.below.
Fig. 2:
Connections at
rear of unit
Fig. 1:
Active control box
indicators
Dimensions
Length: 90mm Width: 72mm Depth: 15mm Cut out diameter is 57mm Overall depth 50mm (ex provision for cables)
4 650Hz 100 5 700Hz 50 6 750Hz 20
7 (most sensitive) 750Hz 20
Table 1: Alarm sensitivity chart
Once the level has reached 7 a further press of the “Alarm” button will cause the sensitivity level to return to level 1. Once the required sensitivity level has been reached the mode will time out after 2 seconds of the last “Alarm” button press and return to normal operation using the chosen sensitivity setting. The sensitivity setting is stored in NVM and is retained for use after power cycling the unit.
Note: the factory default setting is level 6.
Illumination
The brightness of the indicators can be adjusted for day and night vision. To adjust the illumination level of the indicators, press and hold the “Alarm” button for 2 seconds; release the button and the illumination level will change. The illumination level is stored in NVM and is retained for use after power cycling the unit.
Note: the factory default setting is day mode (the brightest level).
S & X-Band Indicators
The toggling of the internal alarm does not affect the operation of the S-Band (YELLOW) or the X-Band (GREEN) indicators. These indicators will illuminate each time the RTE is hit with the relevant RADAR pulse.
Power Connections
Use the 2 way terminal connector provided to connect the unit to the ships supply. Ensure the c
onnector is wired as indicated in Fig. 3.
Note: If the alarm is active on Box 2 the Green LED indicator on Box 1 will show an extended flash whenever a radar pulse is detected. For correct indication, it is suggested to use the alarm o
n Box 1 only. When using an external alarm, the alarm should be wired to Box 1, as shown in Figure 7.
Using Dual Control Boxes with Active-X & X-S RTE
The standard control box may be dual stationed to an exterior waterproof one as shown below.
0V
+12V
PWR
S
HIPS SUPPLY
0V
+12V
Cutting Template
RTE Connections
Use the 3 way terminal connector provided to connect the unit to the active X-S antenna. Ensure the connector is wired as indicated in Fig. 4. If an X Band RTE is being wired just connect the blue and brown wires.
External Alarm Connections
The unit has the ability to supply a switched signal for an external alarm. This alarm will operate along with the internal audible alarm. Use the 4 way terminal connector, provided, to connect the unit to the external alarm. Ensure the connector is wired as indicated in Fig. 5. The “EXT ALARM” connections are a switched relay. The user must provide an external signal to be switched through these relay connections. To enable the external alarm the “EXT ALARM ENABLE” connections must be linked together. It is suggested that this link is made through a toggle switch to provide a means of disabling the external alarm.
Note: disabling the internal audible alarm WILL NOT affect the ex­ternal alarm.
Fig. 5:
External alarm
connectivity
Fig. 6: Dual station connection
Fig. 4: RTE connectivity
0V
+12V
SNS
R
TE
TO ACT IVE
X-S ANTENNA
B
LUE
BROWN
G
REEN
+
YELLOW
EXT
ALA RM
EXT
ALA RM
E
NABLE
EXTERNAL ALARM
SWIT CHED CON TACTS
FOR EXTERNAL ALARM
CONNECT THE ENABLE TERMINALS TOGETHER
INCLUDE A SW ITCH IN
CIRCUIT TO GIVE TOGGLE
CONTROL OF THE EXTERNAL
ALARM FACILITY
Fig. 3: Power supply
Manufactured by
Echomax Products in the UK
PO Box 6032, Dunmow CM6 3AS, UK.
Email: echomaxsales@aol.com www.echomax.co.uk
Tel: 00 44 (0)1371 830216 Fax: 831733
H
O
L
E
S
A
W
ÿ
5
7
m
m
(
2
1
/
4
"
)
90mm
72mm
48 mm
48 mm
DRI
L
L
ÿ
3
m
m
x
4
B
ox 2
F
or
A
ctive X-S
TO ACTIVE X A
NTENNA
T
O ACTIVE X-S
A
NTENNA
T
O EXTERNAL
ALARM
+12v
Box 1 (Standard) Box 2 (Standard)
SHIPS S
UPPLY
+12v
Fig. 7: Connection of External Alarm
For further information on wiring external alarms, see the Active-X and ActiveX-S Operation Manuals
FIT SWITCH
WHEN USING
EXTERNAL
ALARM
SHIPS SUPPLY
To Active XS
SHIPS SUPPLY
Note: Either of the two external alarm terminal options marked can be used. Only one control box can be used to indicate S-Band operation by attaching the yellow/green wire to either of the connections marked above but not both.
To Active X-S
Box 1 (Standard)
Box 2 (Waterproof)
*
*
*