Read rules for safe operation and all instructions carefully. ECHO provides this Operator's
Manual which must be read and understood for proper and safe operation.
X750001720
05/03
2
INTRODUCTION
Welcome to the ECHO family. This ECHO product was designed and manufactured to provide long life and on-the-jobdependability. Read and understand this manual. You will find it easy to use and full of helpful operating tips and
SAFETY messages.
THEOPERATOR'SMANUAL
Read and understand this manual before operation. Keep it in a safe
place for future reference. It contains specifications and information for
operation, starting, stopping, maintenance, storage, and assembly
specific to this product.
- Additional or Replacement Manuals ................2 4
Specifications, descriptions and illustrative material in this
literature are as accurate as known at the time of publication, but are subject to change without notice. Illustrations
may include optional equipment and accessories, and may
not include all standard equipment.
POWER BLOWER
OPERATOR'S MANUAL
MANUAL SAFETY SYMBOLSAND IMPORTANT INFORMATION
Throughout this manual and on the product itself, you will find safety
alerts and helpful, informational messages preceded by symbols or key
words. The following is an explanation of those symbols and key
words and what they mean to you.
This symbol accompanied by the words WARNING and
DANGER calls attention to an act or condition that can lead
to serious personal injury to operator and bystanders.
IMPORTANT
IMPORTANT The enclosed message provides
information necessary for the protection of the
unit.
3
NOTE
The circle with the slash symbol means whatever is shown
within the circle is prohibited.
SAFETY
DECALS
Locate these safety decals on your unit. Make sure the decals are
legible and that you understand and follow the instructions on them.
If a decal cannot be read, a new one can be ordered from your ECHO
dealer. See PARTS ORDERING instructions for specific information.
General Warning Decal (located on top of blower)
NOTE This enclosed message provides tips for
use, care and maintenance of the unit.
Hot Decal (near muffler)
P/N 89016006361
P/N 89016009461
Sound Label (located on blower housing)
73 Category III
Measured at 50 ft. (15m) per ANSI B175.2
dB(A)
P/N X508000160
4
INTERNA TIONAL SYMBOLS
SYMBOL
DESCRIPTIONSYMBOLDESCRIPTION
Read and under-
stand Operator's
Manual.
Wear eyes, ears
and head
protection
Hot
Surface
Safety/Alert
DO NOT allow
flames or sparks
near fuel.
SAFETY INSTRUCTIONS
PERSONAL
CONDITIONANDSAFETYEQUIPMENT
Fuel and oil
mixture
Finger
Severing
Wear hand
protection. Use
two handed.
Wear slip
resistant foot
wear.
DO NOT smoke
near fuel.
SYMBOL
DESCRIPTION
Ignition
ON/OFF
Emergency
Stop
Carburetor
Adjustment
- High speed
mixture
Carburetor
adjustment
- Low speed
mixture
SYMBOL
DESCRIPTION
Primer
Bulb
Choke Control
"Cold Start"
Position
(Choke Closed)
Choke Control
"Run"
Position
(Choke Open)
Carburetor
Adjustment
- Idle speed
W ARNING DANGER
Power Blower users risk injury to themselves and others if the power blower is used improperly or safety precautions
are not followed. Proper clothing and safety gear must be worn when operating a blower.
Physical Condition
Your judgment and physical dexterity may not be good:
• if you are tired or sick,
Hearing Protection
ECHO recommends wearing hearing protection whenever
unit is used.
• if you are taking medication,
• if you have taken alcohol or drugs.
Operate unit only if you are physically and mentally well.
Proper Clothing
Wear snug fitting, durable clothing;
• Pants should have long legs, shirts with long sleeves.
Eye Protection
Wear eye protection that meets ANSI Z87.1 or CE
requirements whenever you operate the unit.
• DO NOT WEAR SHORTS,
• DO NOT WEAR TIES, SCARVES, JEWELRY.
Wear sturdy work shoes with nonskid soles;
• DO NOT WEAR OPEN TOED SHOES,
Hand Protection
Wear no-slip, heavy duty work gloves to improve your
grip on the blower handle. Gloves also reduce the
• DO NOT OPERATE UNIT BAREFOOTED.
Keep long hair away from engine and blower intake. Retain
hair with cap or net.
transmission of machine vibration to your hands.
Hot Humid Weather
Breathing Protection
Wear a face mask to protect against dust.
Heavy protective clothing can increase operator fatigue
which may lead to heat stroke. Schedule heavy work for
early morning or late afternoon hours when temperatures
are cooler.
POWER BLOWER
OPERATOR'S MANUAL
5
EXTENDED
OPERATION/EXTREMECONDITIONS
Vibration and Cold
It is believed that a condition called Raynaud’s Phenomenon, which
affects the fingers of certain individual may be brought about by
exposure to vibration and cold. Exposure to vibration and cold may
cause tingling and burning sensations, followed by loss of color and
numbness in the fingers. The following precautions are strongly
recommended because the minimum exposure which might trigger the
ailment is unknown.
• Keep your body warm, especially the head, neck, feet, ankles, hands,
and wrists.
• Maintain good blood circulation by performing vigorous arm exercises during frequent work breaks, and also by not smoking.
• Limit the hours of operation. Try to fill each day with jobs where
operating the unit or other hand-held power equipment is not
required.
• If you experience discomfort, redness, and swelling of the fingers
followed by whitening and loss of feeling, consult your physician
before further exposing yourself to cold and vibration.
Repetitive Stress Injuries
It is believed that overusing the muscles and tendons of the fingers,
hands, arms, and shoulders may cause soreness, swelling, numbness,
weakness, and extreme pain in those areas. Certain repetitive hand
activities may put you at a high risk for developing a Repetitive Stress
Injury (RSI). An extreme RSI condition is Carpal Tunnel Syndrome
(CTS), which could occur when your wrist swells and squeezes a vital
nerve that runs through the area. Some believe that prolonged exposure
to vibration may contribute to CTS. CTS can cause severe pain for
months or even years.
To reduce the risk of RSI/CTS, do the
following:
• Avoid using your wrist in a bent, extended, or twisted position. Instead try to
maintain a straight wrist position. Also,
when grasping, use your whole hand, not
just the thumb and index finger.
• Take periodic breaks to minimize repetition
and rest your hands.
• Reduce the speed and force with which
you do the repetitive movement.
• Do exercises to strengthen the hand and
arm muscles.
• Immediately stop using all power equipment and consult a doctor if you feel
tingling, numbness, or pain in the fingers,
hands, wrists, or arms. The sooner RSI/
CTS is diagnosed, the more likely permanent nerve and muscle damage can be
prevented.
EQUIPMENT
Before operation a complete check of the unit must be performed:
• Check unit for loose/missing nuts, bolts and screws. Tighten and/or
replace as needed.
• Inspect fuel lines, tank and area around carburetor for fuel leaks. DONOT operate unit if leaks are found.
6
SAFEOPERATION
W ARNING DANGER
Do not operate this product indoors or in inadequately ventilated areas. Engine exhaust contains poisonous
emissions and can cause serious injury or death.
Determine Operation Area
• Review area to be cleared. Look for potential hazards such as stones
or metal objects.
• Take wind conditions into account: avoid open doors and windows.
• Do not point blower at people or animals.
• Start unit on ground with throttle at idle. Check that blower pipe is
not blocked by the ground or by any objects.
Read the Manuals
• Provide all users of this equipment with the Operator's Manual and
Safety Manual for instructions on Safe Operation.
Keep A Firm Grip
• Hold handle with fingers together encircling the handle.
Clear the Work Area
• Spectators and fellow workers must be warned, and children and
animals prevented from coming nearer than 15 m (50 ft.) while the unit
is in use.
Keep A Solid Stance
• Maintain footing and balance at all times. Do not stand on slippery,
uneven or unstable surfaces. Do not work in odd positions or on
ladders.
• Do not perform Maintenance or Assembly procedures with engine
running.
Noise Control
• Follow local noise regulations on sound
levels and hours of operations. Use only
during appropriate hours.
• Never use a higher speed setting then
necessary to perform a task. The higher
the engine speed the louder the blower
noise.
• Be a good neighbor.
Avoid Hot Surfaces
• During operation, the muffler or catalytic
muffler and surrounding cover may
become extremely hot. Avoid contact
during and immediately after operation.
Always keep exhaust area clear of
flammable debris.
EMISSION CONTROL
EPA Phase 1
The emission control system for this engine is EM (Engine Modification).
An Emission Control Label is located on the unit. (This is an
EXAMPLE ONLY, information on label varies by engine FAMILY).
PRODUCT EMISSION DURABILITY
The 300 hour emission durability compliance period is the time span selected by the manufacturer certifying the
engine emissions output meets applicable emissions regulations, provided that approved maintenance procedures are
followed as listed in the Maintenance Section of this manual.
ENGINE FAMILY: 3EHXS.0585RA
DISPLACEMENT: 58.2 CC
THIS ENGINE MEETS U.S. EPA PH1 EMISSION REGULATIONS FOR
SMALL NON ROAD ENGINES. REFER TO OWNER'S MANUAL FOR
MAINTENANCE SPECIFICATIONS AND ADJUSTMENTS.
IMPORTANT ENGINE INFORMATION
DESCRIPTION
CONTENTS
___ 1 - Power Head
___ 1 - Blower Pipe Assembly
___ 1 - Plastic Bag
___ 1 - Operator's Manual
___ 1 - Warranty Registration Card
___ 1 - ECHO Emissions and Warranty Statement
1.AIR CLEANER - Contains replaceable air filter element.
2.SPARK PLUG - Provides spark to ignite fuel mixture.
3.SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER - The muffler or catalytic muffler controls exhaust
noise and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler.
Keep exhaust area clear of flammable debris.
4.RECOIL STARTER HANDLE - Pull recoil handle slowly until starter engages, then quickly and firmly. When
engine starts, return handle slowly. DO NOT let handle snap back or damage to unit will occur.
5.CHOKE - Choke is located on the side of the air cleaner. Move choke lever to "COLD START" () to close choke
for cold starting. Move choke lever to "RUN" () position to open choke.
6.PRIMER BULB - Pumping primer bulb before starting engine draws fresh fuel from the fuel tank priming the
carburetor for starting. Pump primer bulb until fuel is visible and flows freely in the clear fuel tank return line. Pump
bulb an additional 4 or 5 times.
7.FUEL TANK CAP - Covers and seals fuel tank.
8.THROTTLE POSITION LEVER/STOP SWITCH - Combination stop switch and variable speed throttle lever.
When the lever is moved all the way forward the blower is at Wide Open Throttle (W.O.T.). When the lever is
moved rearward to detent, the blower is at idle. When the lever is moved rearward past the idle detent the blower will
stop.
9.BLOWER PIPES - Twist lock design.
10.SAFETY DECAL - Lists important safety precautions.
11.HANDLE - Rotates downward for throttle control access. Spring loaded for flexible operation.
12.SHOULDER HARNESS - Used to support unit on operator's back. The straps are adjustable.
13.FLEXIBLE PIPE - Allows for full range of movement.
14.STICK HANDLE - Provides comfortable grip for directing air flow.
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.