Echelon 100150-201, 100150-281 Setup Manual

LumInsight IoT Gateway and Base Station – Ethernet Rev. B (July 2018)
Setup Guide (Network Configuration) 1 078-1074-01B
LumInsight IoT Gateway and Base Station – Ethernet
Models 100150-201 and 100150-281
Introduction
LumInsight IoT Gateway and Base Station are a set of Echelon’s Edge Servers for use with the LumInsight 2 Central Management System (CMS). The Gateway or Base Station manages a network of lighting controllers and other devices over a LumInsight RF network. The data from the Gateway or Base Station is back-hauled over a LAN/WAN or Cellular connection. This guide is used to set up the LAN/WAN connection.
Setup Guide Overview
This document provides the instructions needed for network configuration for access by a LumInsight CMS. The network settings configuration is end-user specific and requires the appropriate IP address, Netmask, and Default IP Gateway to be obtained from the IT staff at the location where the Ethernet Gateway will be installed. A
LumInsight IoT Gateway Network Information Request (NIR) Form must be completed by the customer’s IT staff.
Information about the NIR form is provided at the end of this guide.
3. Connect the other end of the Ethernet cable to a computer (refer to the figure below).
Ethernet Cable Connection
4. Connect the power adapter to the CloudGate and apply power.
As the CloudGate boots, the system state LED turns orange; wait until it turns green.
When the boot process completes, the computer will have an active network connection with a valid IP address.
5. Open a browser window and go to the address
http://192.168.1.1.
A CloudGate Login page should appear as shown in the screen below, confirming a good Ethernet connection to the CloudGate.
Parts and Accessories
The following parts and accessories are required for the LumInsight IoT Gateway and Base Station network configuration:
Desktop or laptop (recommended) computer with an Ethernet port
CAT 5 patch cable
LumInsight IoT Gateway (Ethernet model number
100150-201) or Base Station (Ethernet model number 100150-281)
Network Settings Configuration
CAUTION: Make sure that the computer being used is not connected to any other network and is configured to receive an IP address from a DHCP server.
To configure the network settings for a LumInsight IoT Gateway and Base Station, perform the following steps:
1. Open the IP66 enclosure and locate the CloudGate device inside (refer to the figure below).
CloudGate Login Page
6. Enter the following credentials to login to the CloudGate web interface:
Username: admin Password: @Echelon123!
7. On the CloudGate Home page, click on the Interfaces menu item and then select the Main Ethernet option as shown in the screen that follows.

CloudGate Device
2. Connect one end of the Ethernet cable to the CloudGate.
Rev. B (July 2018) LumInsight IoT Gateway and Base Station – Ethernet
078-1074-01B 2 Setup Guide (Network Configuration)
11. Select the Firewall menu item and verify that “WAN Local” is set to “Accept”.
12. Click the Save Changes button to save settings.
13. Wait 10 seconds.
CloudGate Home Page
At this point, the settings on the CloudGate Main Ethernet page should appear as shown in the screen that follows.
14. Power off the Ethernet Gateway or Base Station.
15. Disconnect the Ethernet patch cable from the Ethernet Gateway or Base Station.
16. Connect the Ethernet Gateway or Base Station to the Ethernet cable that is connected to the desired LAN.
17. Apply power to the Ethernet Gateway or Base Station.
LumInsight 2 CMS Connection
The step-by-step instructions in this document describe setting up the network configuration and IP address of the Gateway or Base Station.
After completing the steps in the document, additional considerations include:
1. The Gateway or Base Station must be set up to connect through the Internet to the LumInsight Cloud CMS. Doing so requires a valid LumInsight Cloud subscription. Contact Echelon Support for setting up and connecting to the Cloud CMS.
2. A VPN credential is recommended to be set up by the Network Administrator and provided to Echelon Customer Service to enable the Gateway or Base Station to communicate with the LumInsight Cloud CMS, and to help setup or troubleshoot Gateways and Base Stations in the network.
CloudGate Main Ethernet Page
8. In the General section, verify the following settings:
Set “Mode” to “WAN”.
Set “WAN/LAN Switchover” to “No”.
9. In the IP Config section, configure the following settings:
Set “IP address” to the IP address value from the completed LumInsight IoT Gateway NIR Form.
Set “Netmask” to the Netmask value from the completed LumInsight IoT Gateway NIR Form.
Set “Gateway” to the default Gateway IP value from the completed LumInsight IoT Gateway NIR
Form.
Set “DNS 1” to the corporate DNS setting value from the completed LumInsight IoT Gateway NIR Form, or use 8.8.8.8.
10. Click the Save Changes button to save settings.
Additional References and Contact
Additional information and related documentation can be found on the Echelon web site at www.echelon.com.
Please refer to the Echelon Customer Support web site at
http://echelon.com/support for more information.