Ecco ED5051 Series Installation And Operation Instructions Manual

Page 1
!
Installation and Operation Instructions
ED5051 Series Directional LEDs
IMPORTANT! Read all instructions before installing and using. Installer: This manual must be delivered to the end user.
WARNING!
Failure to install or use this product according to manufacturer’s recommendations may result in property damage, serious bodily/personal injury, and/or death to you and those you are seeking to protect!
Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.
1. Proper installation combined with operator training in the use, care, and maintenance of emergency warning devices are essential to ensure the safety of you and those you are seeking to protect.
2. Exercise caution when working with live electrical connections.
3. This product must be properly grounded. Inadequate grounding and/or shorting of electrical connections can cause high
current arcing, which can cause personal injury and/or severe vehicle damage, including re.
5. It is the responsibility of the vehicle operator to ensure during use that all features of this product work correctly. In use, the vehicle operator should ensure the projection of the warning signal is not blocked by vehicle components (i.e., open trunks or compartment doors), people, vehicles, or other obstructions.
6. The use of this or any other warning device does not ensure all drivers can or will observe or react to a warning signal. Never take the right-of-way for granted. It is your responsibility to be sure you can proceed safely before entering an
intersection, driving against trafc, responding at a high rate of speed, or walking on or around trafc lanes.
7. This equipment is intended for use by authorized personnel only. The user is responsible for understanding and obeying all laws regarding warning signal devices. Therefore, the user should check all applicable city, state, and federal laws and regulations. The manufacturer assumes no liability for any loss resulting from the use of this warning device.
Specications:
Size: 5.4” W x 0.6” H X 1.0” D
Weight: 0.14 lbs
Input Voltage: 12-24 VDC
Current at 12.8 VDC: 0.8 Amps
Power at 12.8 VDC: 9.1 Watts
Flash Rate: See ash pattern charts.
Temperature Range: -30° (-22°) to 50°C (122°F)
Page 1 of 6
Page 2
Installation & Mounting:
MOUNTING SURFACE
Offset Mounting:
Carefully remove the unit from its packaging. Examine the unit for transit damage. If damage is found, return the product to your local dealer for warranty replacement. Do not use damaged or broken parts. Determine a mounting location with the least amount of curvature as possible. Also, ensure there is
a clear line of sight for oncoming trafc.
Caution: When drilling into any vehicle surface, make
sure the area is free from any electrical wires, fuel lines, vehicle upholstery, etc. that could be damaged
Surface Mounting:
Mark and drill two 3.4 mm holes 3.543” or 90 mm apart. Drill a hole for the wire exit as needed. Secure in place with the gasket and supplied hardware as shown in FIGURE 1.
Mark and drill two 2.9 mm holes 5.827” or 148 mm apart. Drill a hole for the wire exit as needed. Secure in place with the offset brackets, gaskets and supplied hardware as shown in FIGURE 3.
MOUNTING SURFACE
FIGURE 3
MOUNTING SURFACE
FIGURE 1
L Bracket Mounting:
Mark and drill two 2.9 mm holes 3.937” or 100 mm apart. Drill a hole for the wire exit as needed. Secure in place with the L brackets, gaskets and supplied hardware as shown in FIGURE 2.
Wiring Instructions:
Important! This unit is a safety device and it must
be connected to its own separate, fused power point to assure its continued operation should any other electrical accessory fail.
The ED5051 Series of directional LED light heads are self ashing. All
wiring should be stranded and a minimum of 22 AWG. The positive line must have an in-line 3 Amp slow-blow fuse for each directional as shown in FIGURE 4. Isolate the yellow and blue wires when not in use.
YELLOW ­(SYNC)
BLUE ­FLASH PATTERN SELECT (MOMENTARY TO GROUND)
IN-LINE FUSE
(USER SUPPLIED)
SWITCH
(USER SUPPLIED)
SWITCH
(USER SUPPLIED)
BLACK - GROUND
WHITE -
POSITIVE
(DUAL COLOR
ONLY)
RED - POSITIVE
+ -
FIGURE 2
FIGURE 4
Note: On dual color units only, apply (+) power to the blue wire for dimming.
Page 2 of 6
Page 3
Flash Pattern Selection:
The ED5051 series directionals can be congured to ash the following patterns by momentarily applying ground to the blue wire. Holding
the blue wire to the ground wire for 2-3 seconds will toggle the unit to the previous pattern. The unit must be powered through the power and ground wires to allow pattern selection. The blue wire may be wired to momentarily switch. *Applies to Amber, Red, Blue and White. **Applies to Amber and Blue.
Synchronization:
The ED5051 series directional is capable of syncing with other compatible ECCO products by following the steps below:
1. Set the desired ash pattern on each unit individually. It is also strongly recommended that the same style of ash pattern be used on all units to produce the most effective warning pattern. NOTE: Phases A and B for each style of ash pattern in the table denote the relative
timing between units connected in a synchronizing installation. To operate simultaneously, each unit must be set to the same phase (A + A or B + B); to operate alternately, units must be set to have the opposite phase (A + B or B + A).
2. Connect the yellow sync wires together and check that the units are ashing in a synchronized manner as expected. If a pattern on one
unit appears incorrect, the blue pattern select wire can be used to cycle forward or backward on that individual unit until the correct pattern is selected. NOTE: This will only change the pattern in the one unit and will not affect the other units connected to the yellow sync wire.
ED5051X SINGLE COLOR FLASH PATTERN CHART
Pattern Description Phase FPM SAE J595* CA Title 13**
1 Single Flash A 75 Class 1 Class B
2 Single Flash B 75 Class 1 Class B
3 Single Flash A 120 Class 1
4 Single Flash B 120 Class 1
5 Double Flash A 75 Class 1 Class B
6 Double Flash B 75 Class 1 Blass B
7 Double Flash A 120 Class 1
8 Double Flash B 120 Class 1
9-Default Quad Flash A 75 Class 1 Class B
10 Quad Flash B 75 Class 1 Class B
11
12
13
14
15
16
17
18
Quad Flash A 150 Class 1
Quad Flash B 150 Class 1
Triple Flash A 75 Class 1 Class B
Triple Flash B 75 Class 1 Class B
Quint Flash A 150 Class 1
Quint Flash B 150 Class 1
Steady Burn
Single Flash - Modulation
Page 3 of 6
Page 4
Wires
20 20 36 Double Flash - Alternating Color 1 & 2 A
ED5051XX DUAL COLOR FLASH PATTERN CHART
attern
P
Red Wire White Wire
1 - Default 1 Single Flash - Color 1 A 75 Class 1 Class B
2 2 Single Flash - Color 1 B 75 Class 1 Class B
1 - Default 5 Single Flash - Color 2 A 75 Class 1 Class B
3 3 7 Single Flash - Alternating Color 1 & 2 A 75 4 4 8 Single Flash - Alternating Color 1 & 2 B 75 5 5 9 Single Flash - Alternating Color 6 10 Single Flash - Color 1 A 375 7 11 Single Flash - Color 1 B 375
8 8 16 Single Flash - Alternating Color 1 & 2 A 375
9 9 17 Single Flash - Alternating Color 1 & 2 B 375 10 10 18 Single Flash - Alternating Color 1 & 2 A 11 19 Double Flash - Color 1 A 75 Class 1 Class
2 20 Double Flash - Color 1 B 75 Class 1 Class B
1
13 13 25 Double Flash - Alternating Color 1 & 2 A 75 14 14 26 Double Flash - Alternating Color 1 & 2 B 75 15 15 27 Double Flash - Alternating Color 1 & 2 A 150 16 28 Double Flash - Color 1 A 120 Class 17 2
18 18 34 Double Flash - Alternating Color 1 & 2 A 19 19 35 Double Flash - Alternating Color 1 & 2 B
2 6 Single Flash - Color 2 B 75
6 14 Single Flash - Color 2 A 375 7 15 Single Flash - Color 2 B 375
11 23 Double Flash - Color 2 A 75 Class 1 Class B 12 24 Double Flash - Color 2 B 75 Class 1 Class B
16 32 Double Flash - Color 2 A Class 1 17 33 Double Flash - Color 2 B Class 1
Red & White
3 Single Flash - Alternating Color 1 & 2 A 150 4 Single Flash - Alternating Color 1 & 2 B 150 Class 1 Class B
12 Single Flash - Alternating Color 1 & 2 A 750 13 Single Flash - Alternating Color 1 & 2 B 750
21 Double Flash - Alternating Color 1 & 2 A 150 22 Double Flash - Alternating Color 1 & 2 B 150
9 Double Flash - Color 1 B Class 1 30 Double Flash - Alternating Color 1 & 2 A 31 Double Flash - Alternating Color 1 & 2 B
Description
1 & 2 A 150
Phase FPM SAE J595* CA T13**
750
1 120 240 240 120 120 120 120 240
B
Page 4 of 6
Page 5
Red Wire White Wire
Red & White
Wires
36 69 Steady Burn - Color 2
ED5051XX DUAL COLOR FLASH PATTERN CHART (Continued)
Pattern
21 37 Triple Flash - Color 1 A 75 Class 1 Class B 22 38 Triple Flash - Color 1 B 75 Class 1 Class B
21 41 Triple Flash - Color 2 A 75 Class 1 Class B
22 42 Triple Flash - Color 2 B 75 Class 1 Class B 23 23 43 Triple Flash - Alternating Color 1 & 2 A 75 24 24 44 Triple Flash - Alternating Color 1 & 2 B 75 25 25 45 Triple Flash - Alternating Color 1 & 26 46 27 47 Quad Flash - Color 1 B 75 Class 1 Class B
26 50 Quad Flash - Color 2 A 75 Class 1 Class B
27 51 Quad Flash - Color 2 B 75 Class 1 Class B 28 28 52 - Default Quad Flash - Alternating Color 1 & 2 A 75 29 29 53 Quad Flash - Alternating Color 1 & 2 B 75 30 30 54 Quad Flash - Alternating Color 1 & 31 55 Q 32 56 Quad Flash - Color 1 B 120 Class 1
31 59 Quad Flash - Color 2 A 120 Class 1
32 60 Quad Flash - Color 2 B 120 Class 1 33 33 61 Quad Flash - Alternating Color 1 & 2 A 120 34 34 62 Quad Flash - Alternating Color 1 & 2 B 120 35 35 63 Quad Flash - Alternating Color 1 & 2 A 240
36 68 Steady Burn - Color 1
39 Triple Flash - Alternating Color 1 & 2 A 150 40 Triple Flash - Alternating Color 1 & 2 B 150
Quad Flash - Color 1 A 75 Class 1 Class B
48 Quad Flash - Alternating Color 1 & 2 A 150 49 Quad Flash - Alternating Color 1 & 2 B 150
uad Flash - Color 1 A 120 Class 1
57 Quad Flash - Alternating Color 1 & 2 A 150 58 Quad Flash - Alternating Color 1 & 2 B 150
64 Single Flash - Modulation ­65 Double & Quad Flash - Alternating Color 1 & 2 66 Single & Triple Flash - Alternating Color 1 & 2 67 Double, Triple & Quad Flash - Alternating Color 1 & 2
Description Phase FPM SAE J595* CA T13**
2 A 150
2 A 150
Alternating C
olor 1 & 2
Page 5 of 6
Page 6
Manufacturer Limited Warranty and Limitation of Liability:
Manufacturer warrants that on the date of purchase this product will conform to Manufacturer’s specications for this product (which are available from the
Manufacturer upon request), and Manufacturer further warrants that this product is free from defects in materials and workmanship. This Limited Warranty extends for three (3) years from the date of purchase. Other warranties may apply, call Manufacturer for details. Manufacturer will, at its discretion, repair or replace any product found by the Manufacturer to be defective and subject to this Limited Warranty.
DAMAGE TO PARTS OR PRODUCTS RESULTING FROM TAMPERING, ACCIDENT, ABUSE, MISUSE, NEGLIGENCE, UNAPPROVED MODIFICATIONS, FIRE OR OTHER HAZARD; IMPROPER INSTALLATION OR OPERATION; OR NOT BEING MAINTAINED IN ACCORDANCE WITH THE MAINTENANCE PROCEDURES SET FORTH IN MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS VOIDS THIS LIMITED WARRANTY.
ORAL STATEMENTS OR REPRESENTATIONS ABOUT THE PRODUCT WHICH MAY HAVE BEEN MADE BY SALESPEOPLE, DEALERS, AGENTS OR OTHER MANUFACTURER’S REPRESENTATIVES DO NOT CONSTITUTE WARRANTIES. THIS LIMITED WARRANTY MAY NOT BE AMENDED, MODIFIED, OR ENLARGED EXCEPT BY A WRITTEN AGREEMENT SIGNED BY AN AUTHORIZED OFFICIAL OF MANUFACTURER WHICH EXPRESSLY REFERS TO THIS LIMITED WARRANTY.
Exclusion of Other Warranties: MANUFACTURER MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. THE IMPLIED WARRANTIES FOR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY EXCLUDED AND SHALL NOT APPLY TO THE PRODUCT. BUYER’S SOLE AND EXCLUSIVE REMEDY IN CONTRACT, TORT, OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND ITS USE SHALL BE THE REPLACEMENT OR REPAIR OF THE PRODUCT AS DESCRIBED ABOVE.
Limitation of Liability: IN THE EVENT OF LIABILITY FOR DAMAGES ARISING OUT OF THIS LIMITED WARRANTY OR ANY OTHER CLAIM RELATED TO THE MANUFACTURER’S PRODUCTS, MANUFACTURER’S LIABILITY FOR DAMAGES SHALL BE LIMITED TO THE AMOUNT PAID FOR THE PRODUCT AT THE TIME OF THE ORIGINAL PURCHASE. IN NO EVENT SHALL MANUFACTURER BE LIABLE FOR LOST PROFITS, THE COST OF SUBSTITUTE EQUIPMENT OR LABOR, PROPERTY DAMAGE, OR OTHER SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES BASED UPON ANY CLAIM FOR BREACH OF CONTRACT, IMPROPER INSTALLATION, NEGLIGENCE, OR OTHER CLAIM, EVEN IF MANUFACTURER OR A MANUFACTURER’S REPRESENTATIVE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. MANUFACTURER SHALL HAVE NO FURTHER OBLIGATION OR LIABILITY WITH RESPECT TO THE PRODUCT OR ITS SALE, OPERATION AND USE, AND MANUFACTURER NEITHER ASSUMES NOR AUTHORIZES THE ASSUMPTION OF ANY OTHER OBLIGATION OR LIABILITY IN CONNECTION WITH SUCH PRODUCT.
This Limited Warranty denes specic legal rights. You may have other legal rights, which vary from state to state. Some states do not allow the exclusion
or limitation of incidental or consequential damages.
833 West Diamond St
Boise, Idaho 83705
Customer Service
USA 800-635-5900
UK +44 (0)113 237 5340
AUS +61 (0)3 63322444
www.eccoesg.com
An ECCO SAFETY GROUP™ Brand
www. eccosafetygroup.com
© 2018 ECCO
920-0718-00 Rev. A
Page 6 of 6
Loading...