Ecco VIGILED II, ED0001R, ED0001A, ED0001G, ED0001B Installation And Operation Instruction Manual

...
Ecco VigiLED II series is a small compact directional LED head with inbuilt flash controller. Ideal for internal, grille, bumper or rear mounting they feature a clear lens with coloured LED’s.
Synchronous or Alternative Flash
Dual Voltage – 12/24V
Low Power Consumption – 350mA @ 12 Volt / 200mA @ 24 Volt
Supplied with accessories for surface or bracket mount
Tough die-cast base and Polycarbonate Lens
SAE J595 Class 1 (amber)
ECE R65 (Amber and Blue)
Model Part Numbers Colour
ED0001A
Amber
ED0001B
Blue
ED0001C
Clear (white)
ED0001R
Red
ED0001G
Green
ED0001x VigiLED II SERIES
EMC DIRECTIVE
This product complies with UN ECE R10 for electro-magnetic compatibility (emc)
To maintain compliance with this directive it is necessary that good installation practice is followed and a qualified electrician should be consulted.
The VigiLED should be fitted using either the swivel bracket or surface mounted and orientated as shown with the cable at the bottom.
1. For bracket mount, drill a 12.5mm (0.49”) clearance hole in the required position. Remove the M12 nut and the M12 shakeproof washer from the bolt. Thread the cable through the centre hole in the bolt, fix the VigiLED to the bracket using the M5 rubber washers (ensure that this washer is fitted between the VigiLED and the bracket as shown in Fig.1.), and the M5 round cap screws. Fit the assembly through the drilled hole, thread the M12 shakeproof washer and the M12 nut onto the cable and fix to the bolt. The cable should be fitted with a suitable gland or grommet to ensure a weather proof seal. Ensure that the wire ends of the cable and the end of the cable sheath where connected to the vehicle battery supply are kept dry by protecting the termination against water ingress or by sealing in some other way.
2. For surface mount, drill two 5.3mm (0.21”) clearance holes in the panel 42mm (1.65”) apart, for the VigiLED to the panel using the M5 rubber washers and the M5 round cap screws in Fig.2. A hole for the cable entry will be required and a suitable gland or grommet should be used. Ensure that the wire ends of the cable and the end of the cable sheath where connected to the vehicle battery supply are kept dry by protecting the termination against water ingress or by sealing in some other way.
3. Connect the cable to an appropriate power source (10-30 Volts DC); the total length of the connecting cable from the power source to the light should be less than the 10m (32ft).
Connect the RED to +VDC (fuse@2A) Connect the BLACK to the chassis ground
If two or more beacons are required to flash simultaneously then connect as follows:­Connect the YELLOW wires of all the units together for synchronization
When the YELLOW wires of all the heads are connected together, the group 1 heads will flash in phase (P1) or 180 degrees out of phase (P2) with group 2 heads based in the pattern selected. For example, if the light heads in group 1 have flash pattern 2 selected and group 2 light heads have pattern 3 selected, the group 1/group 2 heads will flash in a five flash alternating mode.
FLASH PATTERNS
Number Description 1 FIVE FLASH ALT 2 FIVE FLASH SIM P1 3 FIVE FLASH SIM P2 4 QUAD FLASH ALT 5 QUAD FLASH SIM P1 6 QUAD FLASH SIM P2 7 SINGLE FLASH 75 ALT 8 SINGLE FLASH 75 SIM P1 9 SINGLE FLASH 75 SIM P2 10 SINGLE FLASH 375 ALT 11 SINGLE FLASH 375 SIM P1 12 SINGLE FLASH 375 SIM P2 13 QUAD-SQUAD FLASH ALT 14 QUAD-SQUAD FLASH SIM 15 MODULATION FLASH ALT 16 MODULATION FLASH SIM 17 QUAD-SQUAD SCAN 18 STEADY BURN WITH SINGLE AND SINGLE POP 19 STEADY BURN - 5 SINGLE 20 STEADY BURN 21 CYCLE FLASH 22 SINGLE FLASH 120 SIM P1 (R65) DEFAULT 23 SINGLE FLASH 120 SIM P2 (R65) 24 TURN OFF
To
select flash pattern, apply the BLUE wire +VDC
Less than 1 second for next pattern
More than 1 second for previous pattern
More than 5 seconds for turn off, when power is reapplied it will resume the previous
pattern
Loading...