Ebyte E34-DTU, 2G4H20 User Manual

E34-DTU (2G4H20)
Chengdu Ebyte Electronic Technology Co.,Ltd. E34-DTU (2G4H20) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 1
1.Introduction............................................................................................................................................ 2
1.1.Brief Introduction .......................................................................................................................... 2
1.2.Features........................................................................................................................................ 2
2.Operation ................................................................ ............................................................................... 3
3.Installation Specifications................................................................................................ ......................... 5
3.1.Structure....................................................................................................................................... 5
3.2.Dimension .................................................................................................................................... 6
4.Interface Defination................................................................................................................................. 7
4.1.Power interface definition ................................................................ ............................................... 7
4.2.RS232 Interface definition .............................................................................................................. 7
4.3.RS485 Interface definition .............................................................................................................. 7
5. Technical indicators ............................................................................................................................ 8
5.1.Model specifications ...................................................................................................................... 8
5.2.General specification parameters ..................................................................................................... 8
5.3.Frequency range and channels ......................................................................................................... 8
5.4.Transmit power level................................................................ ...................................................... 9
5.5.Current parameters ........................................................................................................................ 9
5.6.Transceiver Length and Sub-packing Mode....................................................................................... 9
6.Operating mode ...................................................................................................................................... 9
7.Connection diagram when programming .................................................................................................. 10
7.1.diagrammatic drawing .................................................................................................................. 10
7.2.Parameter setting instruction ................................................................ ..........................................11
8.Connection diagram in test and application ................................ ............................................................... 12
9.E32-DTU series .................................................................................................................................... 13
10.Practical application................................................................ ............................................................. 13
11.Note................................................................ ................................................................................... 14
12.Important statement ............................................................................................................................. 15
Chengdu Ebyte Electronic Technology Co.,Ltd. E34-DTU (2G4H20) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 2
1.Introduction
1.1. Brief Introduction
E34-DTU (2G4H20) is a full duplex wireless data transmission module for point-to-point transmission( Has both RS232 and RS485), transmission power is 100mW, transparent transmission mode, working in 2400MHz band high-performance 2.4g wireless module, UART serial port interface, transparent transmission, at the same time support
3.3v or 5.0v system, packet loss automatic retransmission, support automatic frequency hopping, anti-interference ability is very strong.
E34-DTU (2G4H20) in order to ensure the secrecy and anti-interference of communication, compared with fixed-frequency communication, frequency-hopping communication is more covert and difficult to be intercepted. Support address function, host can transmit data to any address of any channel module, network relay and ot her applications; The air speed is high, so the transmission speed is fast, the delay is small and the data throughput is large. It is especially suitable for applications requiring small delay and large data volume, such as real-time remote control with good anti-interference ability. Even if some frequency points are interfered, it can still carry out normal communication on other frequency points that are not interfered, and it has been mass produced and widely used in related industries
E34-DTU (2G4H20) is Strictly abided by domestic and foreign design specifications such as FCC CE and CCC, meet various rf related certification, and meet export requirements
1.2. Features
All core components are originally imported; our transceiver modems have much advanced functions with smaller size and lower cost.
The top TX power is 100mW, all technical parameters meet European industrial standards. Temperature compensators are adopted to make the frequency stability better than ±1.5PPM.
Operation temperature range: -40℃+85℃, applicab le for various harsh environment, it is real industrial grade
products. Aluminum alloy case, compact size, great heat dispersion; good shielding, prime electromagnetic compatibility and
strong anti-interference.
Power reverse & overload protection and antenna surge protection functions significantly improve the reliability. Parameters can be configured by programming, such as TX power, frequency point, air data rate, address and so on. Ultra-low power consumption, standby current is only 25.5mA (even lower under power -saving and sleep modes), TX
current ≤0.14A .
Embedded watch-dog and precise time layout, modem will restart automatically upon abnormal situation and work with previous parameters. The transceivers adopt original nRF24L01P+ chip, customers highly comment the products because of the super reliability.
Chengdu Ebyte Electronic Technology Co.,Ltd. E34-DTU (2G4H20) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 3
2. Operation
Main parts
1First step is to mount antenna, then battery, making sure the dial switch is on its right status. User gets on the power
by choosing either VCC/GND or power adapter.
2Using USB-(RS232) converter or USB-RS(485) converter or other way to link computer and DTU.
Chengdu Ebyte Electronic Technology Co.,Ltd. E34-DTU (2G4H20) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 4
3Firing up two XCOMs, choosing Baud rate 9600bps, 8N1, the setting which serial port transmission can be
achieved.
4User needs to open the mode switch first before link DTU with computer if the user want to modify parameters.
Firing up E34-DTU 数传电台配置软件 (E34-DTU parameter configuration application) to modify related parameters. The mode switch must be reopened to achieve transmission after the configuration.
Mode 0 Default Mode 3 Parameter setting
Chengdu Ebyte Electronic Technology Co.,Ltd. E34-DTU (2G4H20) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 5
3. Installation Specifications
3.1. Structure
Pin
NO.
Name
Function
Description
1
DB-9 female socket
RS-232 interface
Standard RS-232 interface
2
3.81 terminal block
RS-485, power interface
Standard RS-485 interface and pressure line power interface
3
PWR-LED
Power LED
Red, lit when the power is on
4
TXD-LED
Transmit LED
Yellow, blinks when sending data
5
RXD-LED
Receive LED
Yellow, blinks when receiving data
6
DC power interface
Power interface
In-line round hole, outer diameter 5.5mm, diameter 2.5mm
7
DIP switch
DIP switch
Controlled by working mode
8
Antenna interface
SMA-K interface
external thread, 10mm, 50Ωcharacteristic impedance
Loading...