Ebyte 230N33 User Manual

E90-DTU (230N33)
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 1
1. Introduction ....................................................................................................................................... 2
1.1. Brief Introduction ................................................................................................................. 2
1.2. Certificate ............................................................................................................................ 2
1.3. Features ............................................................................................................................... 3
2. Operation........................................................................................................................................... 3
3. Installation Specification...................................................................................................................... 5
3.1. Structure ................................................................................................ .............................. 5
3.2. Dimension ........................................................................................................................... 7
4. Interface Defination ............................................................................................................................ 8
4.1. Power interface definition ...................................................................................................... 8
4.2. RS232 Interface definition ..................................................................................................... 8
4.3. RS485 Interface definition ..................................................................................................... 8
5. Technical indicators ............................................................................................................................ 9
5.1. Model specifications ............................................................................................................. 9
5.2. Frequency range and channels .............................................................................................. 10
5.3. Transmit power level ........................................................................................................... 10
5.4. Air data rate ....................................................................................................................... 10
5.5. Current parameters................................................................................................ .............. 10
5.6. Transceiver Length and Sub-packing Mode ................................................................ .............11
6. Operating Mode.................................................................................................................................11
7. Connection diagram when programming.............................................................................................. 12
7.1. Diagrammatic drawing ........................................................................................................ 12
7.2. Parameter setting instruction ................................................................................................ 13
8. Connection diagram in test and application .......................................................................................... 14
9. E90 Series........................................................................................................................................ 14
10. Practical application ................................................................................................................... 15
11.Note................................................................ ................................................................................... 15
12.Important statement ............................................................................................................................. 16
Revision history................................ ................................................................................................ ....... 17
About us ................................................................................................................................................ 17
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 2
1. Introduction
1.1. Brief Introduction
E90-DTU (230N33) is a data transmission station with extremely advanced ultra-narrow band modulation technology, which greatly improves the communication distance and communication stability. On the basis of the original built-in power amplifier (PA) and low noise amplifier (LNA), so that the maximum transmission power reaches 2W at the same time the receiving sensitivity has also been improved to a certain extent, in the overall communication stability than no power amplifier and low noise amplifier products greatly improved.
Because E90-DTU (230N33) adopts 230MHz frequency band, it not only ensures the penetrability, but also greatly improves the diffraction ability, making it the best choice for complex and multiple obstacles. The station works in 230MHz frequency band, with communication distance up to 8km. Wireless digital radio as a medium of communication, as well as optical fiber, microwave, open wire, there is a certain scope of application: it provides some special conditions, private network monitoring signals in real-time and reliable data transmission, low cost, easy installation and maintenance, diffraction capability is strong, flexible network structure, the coverage is far characteristic, suitable for some more and occasions, such as dispersion and complex geographical environment with PLC, RTU, rain gauge, level gauge and other data terminal is connected.
1.2. Certificate
E90-dtu has obtained the "radio transmission equipment model approval certificate", whose approval code is CMIIT ID:2017FP5780
E90-DTU has obtained the "explosion-proof certificate", whose number is: test no. 201711000975
E90-dtu has obtained the "electrostatic surge detection report" issued by China testing institute, whose number is CNEx18.1461.
E90-dtu has obtained the "appearance design patent certificate", and its patent number is ZL 2016 3 0501980.3.
E90-DTU has obtained the "utility model patent certificate", and its patent number is ZL 2016 2 1410691.3.
E90-dtu has obtained the "CE certificate" (mandatory eu certification), whose verification number is CCISE180514601V.
E90-DTU has obtained an "FCC certificate" with the ID of 2ALPH-E90-DTU.
E90-DTU has obtained the "RoHS certificate" (mandatory EU environmental protection certification), and its report
number is DTI201807025245.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 3
1.3. Features
All the core components of the original import, compared with the current similar imported digital radio, the most advanced function, the smallest size, the best price.
Large single package, single package maximum support 186 bytes, Modbus adaptation. ★ Simple and efficient power supply design, support power supply device or line pressure mode, support 10~28V
power supply. Super diffraction ability, suitable for complex physical environment, without fear of low density obstacles.
Transmission power up to 2W, and support multi-level adjustable, all technical indicators up to the European industrial standards.
Temperature compensators are adopted to make the frequency stability better than ±1.5PPM. ★ Operation temperature range: -40℃+85℃, applicable for various harsh environment, it is real industrial grade
products All aluminum alloy shell, compact size, easy installation, good heat dissipation; Perfect shielding design, good
electromagnetic compatibility, strong anti - interference ability. Power reverse connection protection, over-connection protection, antenna surge protection and other multiple
protection functions, greatly increasing the reliability of the station. Powerful software functions, all parameters can be set through programming: such as power, frequency, air speed, address ID, ETC Ultra-low power consumption, the standby current is only 19mA (power saving mode and sleep mode power consumption is lower), the emission current 0.8A. Built-in watchdog, and accurate time layout, once an exception, the module will automatically restart, and can
continue to work in accordance with the previous parameter Settings.
2. Operation
Main parts
1First step is to mount antenna, then battery, making sure the dial switch is on its right status. User gets on the power
by choosing either VCC/GND or power adapter.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manu al
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 4
2Using USB-(RS232) converter or USB-RS (485) converter or other way to link computer and DTU.
3Firing up two XCOMs, choosing Baud rate 9600bps, 8N1, the setting which serial port transmission can be
achieved.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 5
4User needs to open the mode switch first before link DTU with computer if the user wants to modify parameters.
Firing up E90-DTU 数 传电台 配置软件 (E90-DTU parameter configuration application) to modify related parameters. The mode switch must be reopened to achieve transmission after the configuration.
模式 0 出厂默认状态 模式 2 进行参数配置
3. Installation Specification
3.1. Structure
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 6
Pin NO.
Name
Function
Description
1
DB-9 female socket
RS-232 interface
Standard RS-232 interface
2
3.81 terminal block
RS-485, power interface
Standard RS-485 interface and pressure line power interface
3
PWR-LED
Power LED
Red, lit when the power is on
4
TXD-LED
Transmit LED
Yellow, blinks when sending data
5
RXD-LED
Receive LED
Yellow, blinks when receiving data
6
DC power interface
Power interface
In-line round hole, outer diameter 5.5mm, diameter 2.5mm
7
DIP switch
DIP switch
Controlled by working mode
8
Antenna interface
SMA-K interface
external thread, 10mm, 50Ωcharacteristic impedance
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 7
3.2. Dimension
单位:mm
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 8
4. Interface Defination
4.1. Power interface definition
Users can choose DC power interface, using the power adapter supply with the interface of the 5.5mm outer diameter , 2.5mm diameter ;
Also choose the VCC and GND terminal power supply, only choose any one of the power supply is OK;
E90-DTU can use 10~ 28V DC power supply, but it is recommended to use 12V or 24V DC power supply.
4.2. RS232 Interface definition
The E90-DTU can be connected to the device via RS-232 using the standard DB-9 interface.
4.3. RS485 Interface definition
E90-DTU can connect the 485_A terminal and 485_B terminal with the device RS-485 A terminal and B terminal.
Pin NO.
Definition
Function
Description
1
VCC
Crimping power interface, positive
10 ~ 28V DC, recommended 12V or 24V
2
GND
Crimping power interface, negative
The power supply negative pole is connected to the system
ground and the housing
3
485_B
RS-485 interface, interface B
The RS-485 interface B is connected to the device interface B
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 9
4
485_A
RS-485 interface, interface A
The RS-485 interface A is connected to the device interface A
Note: The transceiver will be in poor communication when connected to multiple devices , it is recommended to be connected to a single device, please try to use parallel 120Ω resistor between 485_A terminal and 485_B.
5. Technical indicators
5.1. Model specifications
Model
Frequency
Transmit
power
Distance
Specifications
Application
Hz W km
E90-DTU (230N33)
230M 2 8
Super diffraction
ability
Suitable for a variety of complex
application environment with more
obstacles
Note: Test condition: in clear and open air without shelters, 12V /2A power supply, 5dBi gain sucker antenna over 2 meters height from the ground, with the factory default parameters.
NO.
Model
Specification
Description
1
Size(H*W*D)
82 * 62 * 25 mm
See more at 3.2 Dimension
2
Weight
130g
Tolerance: 4.5g
3
Temperature
-40℃85℃
Meet industrial level
4
Antenna impedance
50 Ω
Standard 50 Ω characteristic impedance
5
Supply voltage
+10 ~ +28V DC
It is recommended to use 12V or 24V
6
Communication interface
RS232/RS485
Standard DB9 hole / 3.81 terminal block
7
Baud rate
Default 9600
from 1200 to 115200 bps
8
Address
Default 0
65536 configurable addresses
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 10
5.2. Frequency range and channels
Model
Default frequency
Frequency range
Channel
spacing
Channels Hz
Hz
Hz
E90-DTU (230N33)
230M
225~237.6M
200K
64half duplex
Note: In the same area when multiple data transceivers are communicating one to one at the same time, it is
recommended to set the channel spacing between each group of data transceivers at 2MHz or more.
5.3. Transmit power level
Mode
2W
1W
500mW
250mW
E90-DTU (230N33)
√ √ √
Note: The lower the transmit power, the closer the transmission distance, but the working current won’t be declined in exact proportion, it is recommended to use the maximum transmit power.
5.4. Air data rate
Model
Default air data
rate
Levels
Air data rate(bps)
bps
bps
E90-DTU (230N33)
1.2k
8
1.22.44.89.619.238.45070k
Note: The higher the air data rate, the faster the transmission rate, the transmission distance is also closer; when the rate meets the requirements, the lower air data rate, the better quality.
5.5. Current parameters
Model
Transmitting current mA
Standby current mA
12V
24V
12V
24V
E90-DTU (230N33)
806
396
19
11
Note: It is recommended to retain more than 50% of the current margin when selecting the power supply, which will help the data transceiver to work steadily for a long time.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 11
5.6. Transceiver Length and Sub-packing Mode
Model
Buffer
Sub-package
E90-DTU (230N33)
512 bytes
Automatic subcontracting of 186 bytes to send
Note:
1. If the data received by the station in a single time is larger than the capacity of a single packet, the excess data
will be automatically allocated to the second transmission until the completion of transmission.
2. The data transceiver cannot receive data which is more than the buffer capacity;
6. Operating Mode
E90-DTU (230N33) has four operating modes, if low power consumption is not required, normal communication is recommended to configure the data transceiver for the normal mode (mode 0); The factory default is normal mode (mode 0).
Categories
M1
M0
Description
Mode 0
Normal Mode
ON
ON
Open UART and RFtransparent transmission is on
Mode 1
Wake-up Mode
ON
OFF
Air wake-up mode, the packet comes with a wake-up code,
Mode 2
Power-saving Mode
OFF
ON
The air wake-up receive mode, saving receive power, the mode
cannot be transmitted
Mode 3
Sleep Mode
OFF
OFF
Parameter setting using the configuration software
Note: no need to care about the wake-up mode (mode 1) and power saving mode (mode 2) if it doesn’t request low power consumption.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 12
7. Connection diagram when programming
7.1. Diagrammatic drawing
Mode
M1
M0
Description
Mode 3
Command mode
Off
Off
Only be programmed using the configuration software in the current mode
Note:
1.programming can only be carried on in a specific mode (see above), if fails, please confirm the work mode.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 13
2.If there’s no complicated programming, opening the E90-DTU数传电台配置软件 (E90-DTU parameter configuration
application) to modify parameters.
7.2. Parameter setting instruction
Parameter
Description
Baud rate
The serial port baud rate of a wireless data station at work1200bps115200bps
Odd-even check
Support 8N1:no check 8E1:even-check;8O1:odd-check; Both are 8-bit data bits and 1-bit stop bits.
Air data ratebps
Wireless communication rate, also known as air baud rate air rate high, data transmission speed, transmission of the same data time delay is small, but the transmission distance will become shorter.
Transmitting power
In order to ensure the working efficiency, it is recommended to use the maximum power. If the transmitted power is reduced, the communication distance will become shorter and the required current will be reduced
FEC
The lost or interfered data can be partially corrected by complex encoding, which can improve the equivalent receiving sensitivity by about 3dBm. Turning off this function can reduce the communication delay.
Transmission mode
Fixed length transmission: automatic subcontracting in traditional wireless transmission mode, with a maximum of 77 bytes per packet. Continuous transmission: unlimited packet length, supporting wireless continuous transmission.
Wake Up Time
There is no direct relationship with the communication delay. If the customer needs low-power applications, this option shall be adjusted as required. In the power-saving mode, the longer the wake-up time, the lower the power consumption of the receiving end, and the greater the communication delay.
Station Address
Internal address of wireless data station, stations with the same address as those independent of Modbus address can communicate with each other. This feature can be used to realize software filtering grouping input range :0~65535, decimal number.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 14
Frequency Channel
It is equivalent to the working frequency of the wireless data transmission station. Each channel corresponds to its different working frequency. Theoretically, different frequency channels cannot communicate with each otherIf there are multiple groups of wireless data stations in the same area, the
communication frequency interval is suggested to be 2~5MHz.
Cipher
function
Only stations with the same ciphertext can communicate, and the secondary ciphertext can only be written but cannot be read.
Cipher text set
Radio ciphertext, input range :0 ~ 65535, decimal number.
8. Connection diagram in test and application
9. E90 Series
Mode No.
Interface
Frequency Hz
Tx power
dBm
Distance
km
Function feature
E90-DTU(170L30)
RS232 RS485
170M
30
8
LoRa spread spectrum, ultra-strong through diffraction
E90-DTU(433L30)
RS232 RS485
433M
30
8
LoRa spread spectrum, long distance, anti ­interference
E90-DTU(433L37)
RS232 RS485
433M
37
20
LoRa spread spectrum, 20km long distance, anti
- interference
E90-DTU(433C30)
RS232 RS485
433M
30
3
High-speed continuous transmission, support ModBus protocol
E90-DTU(433C33)
RS232 RS485
433M
33
4
High-speed continuous transmission, support
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 15
ModBus protocol
E90-DTU(433C37)
RS232 RS485
433M
37
10
High-speed continuous transmission, support ModBus protocol, long distance
E90-DTU(230N27)
RS232 RS485
230M
27
5
Low frequency narrow band, suitable for complex environment
E90-DTU(230N33)
RS232 RS485
230M
33
8
Low frequency narrow band, suitable for complex environment
E90-DTU(230N37)
RS232 RS485
230M
37
15
Low frequency narrow band, suitable for complex environment, super diffraction
10. Practical application
The data transceiver of CDEBYTE is applied for all kinds of point to point, one point to multiple points wireless data transmission system, such as smart home, Internet of things transformation, power load monitoring, distribution network automation, hydrological and hydrological forecasting, water pipe network monitoring, urban street lamps Monitoring, air defense alarm control, railway signal monitoring, centralized control of railway water supply, oil supply pipe network monitoring, GPS system, remote meter reading, electronic crane, automatic reporting, seismic forecasting, fire prevention, environmental monitoring and other industrial automation system, as shown below:
11.Note
1. Please keep the warranty card of the equipment which includes the factory number (and important technical
parameters) and is important for user's future maintenance and new equipment.
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 16
2. Transceiver during the warranty period, if the quality of the product itself rather than man-made damage or
lightning and other natural disasters caused by damage, enjoys free warranty; please do not repair by yourself, the problem and please contact with our company when problem occurring, we offer the first-class after-sales service.
3. Please do not operate the transceiver in some flammable places such as coal mines or near explosive atmospheres
(such as detonators).
4. Please use the appropriate DC power supply, high frequency interference ability, s mall ripple, and enough load
capacity are required; it’s better to have over current, over voltage protection and lightning protection and othe r functions to ensure that transceiver working properly.
5. Please do not use it in the working environment beyond the transceiver environmental characteristics , such as
high temperature, humidity, low temperature, strong electromagnetic fields or dust larger environment.
6. Please do not continuously keep transceiver to transmit in full capacity, or the transmitter might be damaged.
7. Please connect the ground with the external ground of the power supply (such as PC, PLC, etc.) , otherwise it is
easy to burn out the communication interface; do not plug the interface with power supplying.
8. When testing, please connect the antenna or 50 Ω load, otherwise transceiver will be da maged easily ;the distance
from the antenna is better than 2 meters, so as to avoid harm, please do not touch the antenna when transmitting.
9. Wireless data transceiver has different communication distance in different environments , communication
distance is influenced by temperature, humidity, obstacle density, obstacle volume and electromagnetic environment; in order to ensure stable communication, it is recommended to reserve at least 50 % of the communication distance.
10. When communication distance is not perfect, it is recommended to improve the antenna quality and the
installation mode of the antenna. You can send mail to support@cdebyte.com for support.
11. When choosing power supply, it is recommended to keep at least 50% current left and the ripple must not exceed
100mV.
12.Important statement
1. CDEBYTE reserves the right of final interpretation and modification of all the contents of this manual.
2. As the hardware and software products continuously improving, this manual may subject to change without notice,
please refer to the latest version.
3. Everyone is responsible for protecting the environment: to reduce the use of paper, we only provide electronic documents of the English manual, if necessary, please go to our official website to download; In addition, for special requirements, we agree to offer certain amount of documents according to order quantity, not every data transceiver are
supplied with one manual, please understand;
Chengdu Ebyte Electronic Technology Co,;Ltd E90-DTU (230N33) user manual
Copyright ©2012–2019Chengdu Ebyte Electronic Technology Co,;Ltd 17
Revision history
version
Date
Description
Issued by
1.20
2019-04-12
initial version
Molly
About us
Technical support: support@cdebyte.com Documents and RF Setting download link: www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com
-----------------------------------------------------------------------------------------------------------­Fax: 028-64146160 ext. 821 Web: www.ebyte.com Address: Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China
Loading...