W2E250-HJ32-01
Nominal data
Type W2E250-HJ32-01
Motor M2E068-DF
AC axial compact fan
sickle-shaped blades (S series)
Phase 1~ 1~
Nominal voltage VAC 115 115
Frequency Hz 50 60
Method of obtaining data fa fa
Valid for approval/standard CE CE
Speed (rpm) min-12600 2850
Power consumption W 115 160
Current draw A 1.02 1.42
Capacitor µF 12 12
Capacitor voltage VDB 220 220
Capacitor standard P0 (CE) P0 (CE)
Max. back pressure Pa 150 120
Max. back pressure inH2O 0.6 0.48
Min. ambient temperature °C -25 -25
Max. ambient temperature °C 70 55
Starting current A 2 2.1
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
Item no. 11386-5-9980 · ENU · Change 89188 · Approved 2016-04-29 · Page 1 / 5

W2E250-HJ32-01
AC axial compact fan
sickle-shaped blades (S series)
Technical description
Weight 3.3 kg
Fan size 250 mm
Rotor surface Painted black
Blade material Sheet steel, painted black
Fan housing material Die-cast aluminum
Number of blades 7
Airflow direction "V"
Direction of rotation Counterclockwise, viewed toward rotor
Degree of protection IP44; installation- and position-dependent
Insulation class "B"
Moisture (F) / Environmental (H)
protection class
Max. permitted ambient temp.
for motor (transport/storage)
Min. permitted ambient temp. for
motor (transport/storage)
Installation position Any
Condensation drainage holes None
Mode S1
Motor bearing Ball bearing
Touch current according to IEC
60990 (measuring circuit Fig. 4,
TN system)
Electrical hookup Via terminal strip, capacitor connected
Motor protection Thermal overload protector (TOP) internally connected
With cable Variable
Protection class I (with customer connection of protective earth)
Motor capacitor according to EN
60252-1 in safety protection class
Conformity with standards EN 60335-1; CE
Approval CCC; UL 2111; CSA C22.2 No. 77
H0+
+ 80 °C
- 40 °C
< 0.75 mA
P0/S0
Item no. 11386-5-9980 · ENU · Change 89188 · Approved 2016-04-29 · Page 2 / 5

W2E250-HJ32-01
Product drawing
AC axial compact fan
sickle-shaped blades (S series)
1 Direction of air flow "V"
Connection diagram
L blue N black PE green/yellow
Item no. 11386-5-9980 · ENU · Change 89188 · Approved 2016-04-29 · Page 3 / 5

W2E250-HJ32-01
Curves: Air performance 50 Hz
220
210
200
190
180
170
160
150
140
130
120
110
p f s[Pa]
100
90
80
70
60
50
40
30
20
10
0
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[cfm]
qv[m^3/h]
AC axial compact fan
sickle-shaped blades (S series)
1.2001.0008006004002000
0,85
0,8
0,75
0,7
0,65
0,6
0,55
0,5
4
3
2
p f s[Pa]
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
1
0
2.0001.8001.6001.4001.2001.0008006004002000
pfs _E[IN H2O]
Measurement: LU-29333-1
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
Measured values
U
V
1
2
3
4
U = Power supply · f = Frequency · n = Speed (rpm) · Pe= Power consumption · I = Current draw · qv = Air flow · pfs= Pressure increase
115
115
115
115
f
Hz
50
50
50
50
n
min
2600
2570
2505
2435
P
-1
W
115
128
137
147
I
e
A
1.02
1.12
1.20
1.29
qv
m3/h
1900
1735
1515
1190
p
Pa
0
40
80
110
qv
fs
CFM
1120
1020
890
700
p
fs
inH2O
0.00
0.16
0.32
0.44
Item no. 11386-5-9980 · ENU · Change 89188 · Approved 2016-04-29 · Page 4 / 5

W2E250-HJ32-01
Curves: Air performance 60 Hz
180
175
170
165
160
155
150
145
140
135
130
125
120
115
110
105
100
95
90
p f s[Pa]
85
80
75
70
65
60
55
50
45
40
35
30
25
20
15
10
5
0
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[cfm]
4
qv[m^3/h]
AC axial compact fan
sickle-shaped blades (S series)
1.2001.0008006004002000
3
2
p f s[Pa]
0,72
0,7
0,68
0,66
0,64
0,62
0,6
0,58
0,56
0,54
0,52
0,5
0,48
0,46
0,44
0,42
0,4
0,38
0,36
0,34
0,32
pfs _E[IN H2O]
0,3
0,28
0,26
0,24
0,22
0,2
0,18
0,16
0,14
0,12
0,1
0,08
0,06
0,04
0,02
1
0
2.2002.00 01.8001.6001.4 001.2001.0 0080060040020 00
Measurement: LU-29334-1
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
Measured values
U
V
1
2
3
4
U = Power supply · f = Frequency · n = Speed (rpm) · Pe= Power consumption · I = Current draw · qv = Air flow · pfs= Pressure increase
115
115
115
115
f
Hz
60
60
60
60
n
min
2850
2760
2620
2445
P
-1
W
160
178
185
194
I
e
A
1.42
1.53
1.60
1.68
qv
m3/h
2075
1880
1620
1200
p
Pa
0
40
80
110
qv
fs
CFM
1220
1105
955
705
p
fs
inH2O
0.00
0.16
0.32
0.44
Item no. 11386-5-9980 · ENU · Change 89188 · Approved 2016-04-29 · Page 5 / 5