Nominal data
Type R4E225-RA04-10
Motor M4E068-CF
AC centrifugal fan
backward-curved, single-intake
Phase 1~ 1~ 1~
Nominal voltage VAC 230 230 230
Method of obtaining data ml ml ml
Valid for approval/standard CE CE UL 1004-3
Speed (rpm) min-11370 1570 1570
Current draw A 0.14 0.18 0.19
Capacitor µF 1 1 1
Capacitor voltage VDB 400 400 400
Capacitor standard S0 (CE) S0 (CE) UL
Min. back pressure Pa 0 0 0
Min. back pressure in. wg 0 0 0
Min. ambient temperature °C -25 -25 -25
Starting current A 0.3 0.3 0.31
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment Subject to change
Item no. 16390-5-9980 · ENU · Change 92090 · Approved 2017-07-04 · Page 1 / 6
R4E225-RA04-10
AC centrifugal fan
backward-curved, single-intake
Technical description
Weight 1.8 kg
Fan size 225 mm
Rotor surface Painted black
Impeller material PA plastic
Number of blades 7
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP44; installation- and position-dependent as per EN 60034-5
Insulation class "B"
Moisture (F) / Environmental (H) protection class
Max. permitted ambient temp. for motor (transport/storage)
Min. permitted ambient temp. for motor (transport/storage)
Installation position Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes On rotor side
Mode S1
Motor bearing Ball bearing
Touch current according to IEC 60990 (measuring circuit Fig. 4, TN system)
Motor protection Thermal overload protector (TOP) internally connected
With cable Variable
Protection class I (with customer connection of protective earth)
Conformity with standards EN 60335-1; CE
Approval CSA C22.2 No. 77; UL 1004-3
H0+
+ 80 °C
- 40 °C
< 0.75 mA
Item no. 16390-5-9980 · ENU · Change 92090 · Approved 2017-07-04 · Page 2 / 6
R4E225-RA04-10
Product drawing
AC centrifugal fan
backward-curved, single-intake
1 Accessory part: inlet ring 96358-2-4013 not included in scope of delivery
2 Max. clearance for screw 5 mm
3 Cable PVC AWG20, 4x crimped splices
Item no. 16390-5-9980 · ENU · Change 92090 · Approved 2017-07-04 · Page 3 / 6
R4E225-RA04-10
Accessory part
AC centrifugal fan
backward-curved, single-intake
1 Accessory part: inlet ring 96358-2-4013 not included in scope of delivery
Connection diagram
U1 blue Z brown U2 black
PE green/yellow
Item no. 16390-5-9980 · ENU · Change 92090 · Approved 2017-07-04 · Page 4 / 6
R4E225-RA04-10
qv m³/h
cfm
pfs
Pa
in. wg
100 200 300 400 500
0 50 100 150 200 250 300
30
60
90
120
0.1
0.2
0.3
0.4 0.5
1
2
3
4
Curves: Air performance 50 Hz
AC centrifugal fan
backward-curved, single-intake
ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-185276-1
Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit.
Measured values
U
V
1
2
3
4
U = Power supply · f = Frequency · n = Speed (rpm) · Pe= Power consumption · I = Current draw · LpAin= Sound pressure level intake side · LwAin= Sound power level intake side
qV= Air flow · pfs= Pressure increase
230
230
230
230
f
Hz
50
50
50
50
n
min
1410
1380
1370
1395
P
-1
W
28
31
31
29
I
e
A
0.13
0.14
0.14
0.13
LpA
dB(A)
51
46
42
43
LwA
in
dB(A)
59
54
49
51
q
in
m3/h
610
500
385
235
p
V
Pa
0
50
90
115
q
fs
V
cfm
360
295
225
140
p
fs
in. wg
0.00
0.20
0.36
0.46
Item no. 16390-5-9980 · ENU · Change 92090 · Approved 2017-07-04 · Page 5 / 6
R4E225-RA04-10
qv m³/h
cfm
pfs
Pa
in. wg
100 200 300 400 500 600 700
0 100 200 300 400
50
100
150
0.2 0.4 0.6
1
2
3
4
Curves: Air performance 60 Hz
AC centrifugal fan
backward-curved, single-intake
ρ = 1.15 kg/m³ ± 2 %
Measurement: LU-185269-1
Air performance measured according to ISO 5801 installation category A. For detailed information on the measurement setup, contact ebm-papst. Intake sound level: Sound power level according to ISO 13347 / sound pressure level measured at 1 m distance from fan axis. The values given are valid under the specified measuring conditions and may vary due to conditions of installation. For deviations from the standard configuration, the parameters have to be checked on the installed unit.
Measured values
U
V
1
2
3
4
U = Power supply · f = Frequency · n = Speed (rpm) · Pe= Power consumption · I = Current draw · LpAin= Sound pressure level intake side · LwAin= Sound power level intake side
qV= Air flow · pfs= Pressure increase
230
230
230
230
f
Hz
60
60
60
60
n
min
1640
1585
1570
1605
P
-1
W
35
39
40
37
I
e
A
0.15
0.17
0.18
0.16
LpA
dB(A)
54
50
46
46
LwA
in
dB(A)
62
58
54
54
q
in
m3/h
730
600
440
295
p
V
Pa
0
60
120
150
q
fs
V
cfm
430
355
260
175
p
fs
in. wg
0.00
0.24
0.48
0.60
Item no. 16390-5-9980 · ENU · Change 92090 · Approved 2017-07-04 · Page 6 / 6
Loading...