ebm-papst R2E220-AA40-23 Data Sheet

R2E220-AA40-23
Nominal data
Type R2E220-AA40-23
Motor M2E068-BF
AC centrifugal fan
backward curved, single inlet
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen Phone +49 7938 81-0 Fax +49 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner: Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Phase 1~ 1~ 1~
Nominal voltage VAC 230 230 230
Frequency Hz 50 60 60
Type of data definition fa fa fa
Valid for approval / standard CE UL 2111 CE
Speed min-12600 2700 2700
Power input W 85 100 90
Current draw A 0.38 0.43 0.40
Motor capacitor µF 3 2 2
Capacitor voltage VDB 400 400 400
Capacitor standard P0 (CE) UL P0 (CE)
Min. back pressure Pa 0 0 0
Max. ambient temperature °C 40 40 40
ml = max. load · me = max. efficiency · fa = running at free air · cs = customer specs · cu = customer unit Subject to alterations
Item no.: 10540-5-9980 · Revision: 68158 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 1 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AA40-23
AC centrifugal fan
backward curved, single inlet
Technical features
Mass 1.3 kg
Size 220 mm
Surface of rotor Uncoated
Material of impeller Plastic PA6, fibreglass-reinforced
Number of blades 11
Direction of rotation Clockwise, seen on rotor
Type of protection IP 44; Depending on installation and position
Insulation class "B"
Humidity class F0
Max. permissible ambient motor temp. (transp./ storage)
Min. permissible ambient motor temp. (transp./storage)
Mounting position Any
Condensate discharge holes None
Operation mode S1
Motor bearing Ball bearing
Leakage current < 0.75 mA
Motor protection Thermal overload protector (TOP) wired internally
Cable exit Variable
Protection class I (if protective earth is connected by customer)
Product conforming to standard
Approval CSA C22.2 Nr.113; CCC; UL 507
+ 80 °C
- 40 °C
EN 60335-1; CE
Item no.: 10540-5-9980 · Revision: 68158 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 2 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AA40-23
Product drawing
AC centrifugal fan
backward curved, single inlet
1 Connection line PVC, 4x brass lead tips crimped
2 Accessory part: Inlet nozzle 09609-2-4013, not included in the standard scope of delivery
3 Depth of screw max. 5 mm
Connection screen
U1 blue Z brown U2 black
PE green/yellow
Item no.: 10540-5-9980 · Revision: 68158 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 3 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AA40-23
Charts: Air flow 50 Hz
390 380 370 360 350 340 330 320 310 300 290 280 270 260 250 240 230 220 210 200 190
p sf[Pa]
180 170 160 150 140 130 120 110 100
90 80 70 60 50 40 30 20 10
0
4
Druck p sf[Pa]für Rho=1,2kg/m^3
qv[cfm]
3
qv[m^3/h]
AC centrifugal fan
backward curved, single inlet
500450400350300250200150100500
1,55
1,5
1,45
1,4
1,35
1,3
1,25
1,2
1,15
1,1
1,05
1
0,95
0,9
0,85
0,8
0,75
0,7
psf _E[IN H2O]
0,65
0,6
0,55
0,5
0,45
p sf[Pa]
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
1
0
900850800750700650600550500450400350300250200150100500
2
Measurement: LU-106763
Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed.
Measured values
U
V
1
2
3
4
230
230
230
230
f
Hz
50
50
50
50
n
min
2405
2260
2155
2245
P
-1
W
85
91
94
91
I
e
A
0.38
0.39
0.41
0.40
qv
m3/h
865
680
460
230
p
Pa
0
90
180
260
sf
Item no.: 10540-5-9980 · Revision: 68158 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AA40-23
Charts: Air flow 60 Hz
460
440
420
400
380
360
340
320
300
280
260
240
p sf[Pa]
220
200
180
160
140
120
100
80
60
40
20
0
4
Druck p sf[Pa]für Rho=1,2kg/m^3
qv[cfm]
3
qv[m^3/h]
AC centrifugal fan
backward curved, single inlet
550500450400350300250200150100500
1,85
1,8 1,75 1,7
1,65 1,6 1,55
1,5 1,45 1,4
1,35 1,3 1,25 1,2
1,15 1,1 1,05
1 0,95 0,9
0,85
psf _E[IN H2O]
0,8 0,75
0,7 0,65 0,6
0,55 0,5 0,45 0,4
p sf[Pa]
0,35 0,3 0,25
0,2 0,15 0,1
0,05
1
95090085080075070065060055 050045040035 03002502001501 00500
2
Measurement: LU-106764
Air performance measured as per ISO 5801 Installation category A. For detailed information on the measuring set-up, please contact ebm-papst. Suction-side noise levels: LwA measured as per ISO 13347 / LpA measured with 1m distance to fan axis. The values given are valid under the measuring conditions mentioned above and may vary according to the actual installation situation. With any deviation from the standard set-up, the specific values have to be checked and reviewed with the unit installed.
Measured values
U
V
1
2
3
4
230
230
230
230
f
Hz
60
60
60
60
n
min
2490
2265
2020
2100
P
-1
W
84
90
94
93
I
e
A
0.37
0.39
0.41
0.40
qv
m3/h
895
715
470
265
p
Pa
0
70
140
220
sf
Item no.: 10540-5-9980 · Revision: 68158 · Print-out: 2012-02-09 · Y. Uhlmann (VM-TDO) · Page 5 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 7938 81-0 · Fax +49 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Loading...