Translation of the original operating instructions
1. SAFETY REGULATIONS AND NOTES
Please read these operating instructions carefully before starting to work
with the device. Observe the following warnings to prevent malfunctions
or physical damage to both property and people.
These operating instructions are to be regarded as part of this device.
If the device is sold or transferred, the operating instructions must
accompany it.
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
11. SAFETY REGULATIONS AND NOTES
11.1 Levels of hazard warnings
11.2 Staff qualification
11.3 Basic safety rules
11.4 Electrical voltage
21.5 Safety and protective functions
21.6 Mechanical movement
21.7 Emission
21.8 Hot surface
21.9 Transport
21.10 Storage
21.11 Disposal
32. PROPER USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Technical features
53.4 Mounting data
53.5 Transport and storage conditions
64. CONNECTION AND START-UP
64.1 Connecting the mechanical system
64.2 Connecting the electrical system
64.3 Connection of the cables
74.4 Connection screen
84.5 Checking the connections
84.6 Switch on device
84.7 Switching off the device
85. MAINTENANCE, MALFUNCTIONS, POSSIBLE
95.1 Cleaning
95.2 Safety test
1.1 Levels of hazard warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury. Compliance with
the measures is mandatory.
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury. Exercise extreme
caution while working.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury or damage of property.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
1.2 Staff qualification
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by qualified, trained and authorised
technical staff.
Only authorised specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
Observe the following when working on the unit:
; Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
1.4 Electrical voltage
; Check the electrical equipment of the device at regular intervals, refer
to chapter 5.2 Safety test.
; Replace loose connections and defective cables immediately.
DANGER
Electrical load on the device
Risk of electric shock
→ Stand on a rubber mat if you are working on an electrically
charged device.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
The device is exclusively designed as a built-in device for moving air
according to its technical data.
Any other or secondary use is deemed improper and constitutes a
misuse of the device.
Installations on the customer's side must meet the mechanical, thermal
and service life-related stresses that can occur.
Proper use also includes:
● Moving air with a density of 1.2 kg/m³.
● Using the device in accordance with the permitted ambient
temperature, see chapter 3.5 Transport and storage conditions and
chapter 3.2 Nominal data.
● Operating the device with all protective features in place.
● Minding the operating instructions.
Improper use
Using the device in the following ways is particularly prohibited and
may cause hazards:
● Operating the device with an imbalance, e.g. caused by dirt deposits
or icing.
● Moving air that contains abrasive particles.
● Moving highly corrosive air, e.g. salt spray mist. Exceptions are
devices that are intended for salt spray mist and protected accordingly.
● Moving air that contains dust pollution, e.g. suctioning off saw dust.
● Operating the device close to flammable materials or components.
● Operating the device in an explosive atmosphere.
● Using the device as a safety component or for taking on safety-
related functions.
● Operation with completely or partially disassembled or modified
protective features.
● In addition, all application options that are not listed under proper use.
Translation of the original operating instructions
1Connection line PVC 4G 0.5 mm², 4x brass lead tips crimped
2Depth of screw max. 5 mm
3Accessory part: Inlet nozzle 09569-2-4013, not included in the standard scope of delivery
Translation of the original operating instructions
Phase1~1~
Nominal voltage / VAC230230
Frequency / Hz5060
Type of data definitionfafa
Valid for approval /
standard
Speed / min
Power input / W80100
Current draw / A0.350.44
Motor capacitor / µF22
Capacitor voltage / VDB450450
Capacitor standardP0 (CE)P0 (CE)
Min. back pressure / Pa00
Min. ambient temperature
/ °C
Max. ambient
temperature
/ °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
-1
CECE
23502450
-25-25
5560
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
You can obtain additional mounting data from the product drawing if
necessary.
8.8
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
Min. permissible
ambient motor temp.
(transp./storage)
+ 80 °C
- 40 °C
3.3 Technical features
Mass1.2 kg
Size120 mm
Material of impellerSheet steel, hot-galvanised
Direction of rotationClockwise, seen on rotor
Type of protectionIP 44
Insulation class"B"
Humidity classF0
Mounting positionAny
Condensate discharge
holes
Operation modeS1
Motor bearingBall bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
Motor protectionThermal overload protector (TOP) wired
Cable exitVariable
Protection classI (if protective earth is connected by
Product conforming
to standard
ApprovalCCC; EAC
Translation of the original operating instructions
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
CAUTION
Cutting and crushing hazard when removing the fan
from the packaging
→ Carefully hold the impeller to remove the device from its
packaging. Make sure to avoid any shock.
→ Wear safety shoes and cut-resistant safety gloves.
; Check the device for transport damage. Damaged devices must no
longer be installed.
; Install the undamaged device according to your application.
4.2 Connecting the electrical system
DANGER
Electric voltage on the device
Electric shock
→ Always install a protective earth first.
→ Check the protective earth.
DANGER
Incorrect insulation
Risk of fatal injury from electric shock
→ Use only cables that meet the specified installation
requirements for voltage, current, insulation material, load etc.
→ Route cables such that they cannot be touched by any
rotating parts.
CAUTION
Electrical voltage
The fan is a built-in component and features no electrically
isolating switch.
→ Only connect the fan to circuits that can be switched off with
an all-pole separating switch.
→ When working on the fan, you must switch off the
installation/machine in which the fan is installed and secure it
from being switched on again.
NOTE
Water penetration into leads or wires
Water enters at the cable end on the customers side and can
damage the device.
→ Make sure that the cable end is connected in a dry
environment.
Connect the device only to circuits that can be switched off
using an all-pole disconnecting switch.
cable cross-section is at least
AWG26/0.13 mm².
4.2.2 Voltage control
With open loop speed control using transformers or electronic
voltage regulators (e.g. phase angle control), excessive current
may occur.
In addition, noises can occur with phase angle control
depending on the mounting situation.
4.2.3 Frequency inverter
Please use a frequency converter only after consultation with ebm-papst.
Fit sinusoidal filters that work on all poles (live-live and liveearth) between the frequency inverter and the motor for
operation with frequency inverters.
Depending on how the device is installed, noises may occur.
Heating of the motor due to use of a frequency converter must be
checked in the application by the customer.
4.3 Connection of the cables
External leads are brought out of device.
; First connect the "PE" (protective earth) connection.
● Connect the lines according to your application. When doing so,
observe chapter 4.4 Connection screen.
4.2.1 Prerequisites
; Check whether the data on the type plate agree with the connection
data and the data of the operating capacitor.
; Before connecting the device, ensure that the supply voltage matches
Translation of the original operating instructions
the operating voltage of the device.
; Only use cables designed for current according to the type plate.
For determining the cross-section, follow the basic principles in
accordance with EN 61800-5-1. The protective earth must have a
cross-section equal to or greater than the outer conductor crosssection.
We recommend the use of 105°C cables. Ensure that the minimum
The device may only be switched on if it has been installed properly and
in accordance with its intended use, including the required safety
mechanisms and professional electrical connection. This also applies for
devices which have already been equipped with plugs and terminals or
similar connectors by the customer.
WARNING
Hot motor housing
Fire hazard
→ Ensure that no combustible or flammable materials are
located close to the fan.
; Inspect the device for visible external damage and the proper function
of the protective features before switching it on.
; Check the air flow paths of the fan for foreign objects and remove any
that are found.
; Apply the nominal voltage to the voltage supply.
4.7 Switching off the device
; Disconnect the device from the supply voltage at the main switch for
the supply line.
; When disconnecting, be sure to disconnect the earth wire connection
last.
Translation of the original operating instructions
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
Do not perform any repairs on your device. Return the device to ebmpapst for repair or replacement.
WARNING
Terminals and connections have voltage even with a
unit that is shut off
Electric shock
→ Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION
Electrical load on the capacitor after device is switched off
Electric shock, risk of injury
→ Discharge the capacitors before working on the device.
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Danger of injury
→ Keep out of the danger zone of the device.
→ When working on the device, switch off the mains
supply voltage and secure the latter from being switched on
again.
→ Wait until the device stops.
If the device remains out of use for some time, e.g. when in
storage, we recommend switching the device on for at least
two hours to allow any condensate to evaporate and to move
the bearings.
Motor does not turnMechanical blockageSwitch off, de-
Imbalance in rotating
parts
Mains supply
voltage faulty
Faulty connectionDe-energise, correct
Thermal overload
protector responded
Clean the device; if
imbalance is still
evident after
cleaning, replace the
device.
If you have
attached any weight
clips during cleaning,
make sure to
remove them
afterwards.
energise, and
remove mechanical
blockage.
Check mains supply
voltage,
restore power
supply.
connection, see
connection diagram.
Allow motor to cool
off, locate and rectify
cause of error, if
necessary cancel
restart lock-out
If you have any other problems, contact ebm-papst.
5.1 Cleaning
NOTE
Damage to the device during cleaning.
Malfunction possible
→ Do not clean the device using a water jet or high-pressure
washer.
→ Do not use any cleaners containing acids,
bases or solvents.
→ Do not use any pointed or sharp-edged objects to clean.
5.2 Safety test
What has to
be tested?
Check the
protective
casing against
accidental
contact for
damage and to
ensure that it is
intact
Check the
device for
damage to
blades and
housing
Mounting the
connection lines
Mounting of
protective
earth connection
Check the
insulation of
the wires for
damage
Impeller for
wear/deposits/
corrosion and
damage
Unacceptable
operating point
Ambient temperature
too high
Insufficient coolingImprove cooling
How to test?FrequencyWhich
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Visual inspection At least every
6 months
Check operating point
Lower ambient
temperature if possible
measure?
Repair or
replacement of
the device
Replacement
of the device
Fasten
Fasten
Replace wires
Clean or
replace impeller
Translation of the original operating instructions