EBM-PAPST PAPST ACI4420MLR Datasheet [de]

Page 1
Product Data Sheet ACi 4420 MLR
Page 2
Product Data Sheet ACi 4420 MLR
ACi 4420 MLR
INDEX
1 General ...................................................................................................................................................................... 3
2 Mechanics ................................................................................................................................................................. 3
3 Operating Data .......................................................................................................................................................... 5
4 Environment .............................................................................................................................................................. 9
5 Safety ....................................................................................................................................................................... 10
6 Reliability ................................................................................................................................................................. 10
3/9/2015 page 2 of 11
Page 3
Fan type
Fan
Rotational direction looking at rotor
clockwise
Airflow direction
Air outlet over struts
Bearing system
Ball bearing
Mounting position
any
Width
120 mm
Height
120 mm
Depth
38,0 mm
Diameter
0,0 mm
Weight
0,275 kg
Housing material
Plastic
Impeller material
Plastic
Max. torque when mounted across both mounting flanges
wire outlet corner: 50 Ncm remaining corners: 80 Ncm
Screw size
ISO 4762 - M4 degreased, without an additional brace and without washer
1 General
2 Mechanics
2.1 General
Product Data Sheet ACi 4420 MLR
3/9/2015 page 3 of 11
Page 4
2.2 Connections
Electrical connection
Plug
Length of lead wire
see drawing
Tolerance
Length of tube
see drawing Tolerance
Wire gauge (AWG)
Insulation diameter
Plug
see drawing
Contact
see drawing
Product Data Sheet ACi 4420 MLR
3/9/2015 page 4 of 11
Page 5
3 Operating Data
External voltage supply for input and output signals must be SELV conform.
Features
Condition
Symbol
Values
Voltage range
p = 0 U
Nominal voltage
p = 0
UN 230 V
Frequency
p = 0
f
50 Hz
Power consumption
p = 0
P
1,7 W
Tolerance
+- 20,0 %
Speed
p = 0
n
1.850 1/min
Tolerance
+- 10,0 %
External voltage supply for input and output signals must be SELV conform.
Tacho type
None
Alarm type
None
3.1 Operating Data - Electrical Interface - Input
3.2 Electrical Operating Data
Product Data Sheet ACi 4420 MLR
3.3 Operating Data - Electrical Interface -Output
3/9/2015 page 5 of 11
Page 6
3.4 Electrical Features
Electronic function
Speed-Controlled
Locked rotor protection
Auto restart
Clock signal t3/t4 at locked rotor
Typical: 0,25 s / 10,0 s
Product Data Sheet ACi 4420 MLR
3/9/2015 page 6 of 11
Page 7
Measurement conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. The information is only valid under the specified test conditions and may be changed by the installation conditions. If there are deviations from the standard test conditions, the characteristic values must be checked under the installed conditions.
1.850 1/min at free air flow
Frequency: 50 Hz
Nominal voltage: 230 V
Max. free-air flow (p = 0 / = max.)
100,0 m3/h
Max. static pressure (p = max. / =0)
48 Pa
at free air flow
Frequency:
Nominal voltage:
Max. free-air flow (p = 0 / = max.)
Max. static pressure (p = max. / =0)
3.5 Aerodynamic
a) Operation condition:
b) Operation condition:
Product Data Sheet ACi 4420 MLR
3/9/2015 page 7 of 11
Page 8
3.6 Sound Data
Measurement conditions:
Sound pressure level: 1 Meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see section 3.4
1.850 1/min at free air flow
Frequency: 50 Hz
Nominal voltage: 230 V
Optimal operating point
84,0 m3/h @ 7 Pa
Sound power level at the optimal operating point
4,1 bel(A)
Sound pressure level at free air flow, measured in rubber bands
25,0 dB(A) at free air flow
Frequency:
Nominal voltage:
Optimal operating point
Sound power level at the optimal operating point
Sound pressure level at free air flow, measured in rubber bands
a) Operation condition:
b) Operation condition:
Product Data Sheet ACi 4420 MLR
3/9/2015 page 8 of 11
Page 9
Min. permitted ambient temperature TU min.
-20 °C
Max. permitted ambient temperature TU max.
75 °C
Min. permitted storage temperature TL min.
-40 °C
Max. permitted storage temperature TL max.
80 °C
Humidity requirements
humid heat, cyclic; according to DIN EN 60068-2-30, 6 cycle
Water exposure
None
Radiation exposure
None
Dust requirements
Dust check; according to DIN EN 60068-2-68, 6g/m2d, 1 day
Salt fog requirements
None
Harmful gas requirements
None
4 Environment
4.1 General
4.2 Climatic requirements*)
Product Data Sheet ACi 4420 MLR
*) Permittet application area: The product is for the use in sheltered rooms with limited controlled temperature. Occasionally condensed water is allowed. Direct exposure to water must be avoided. Saline ambient conditions must be avoided. Pollution degree 2 (according DIN EN 60664-1) It occurs only non-conductive pollution. Occassionally, temporary conductivity caused by condensation occurs.
3/9/2015 page 9 of 11
Page 10
A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock, ingress of solid foreign objects and water has to be done in conjuction with the appliance.
Test voltage HV type test
3000 V
Unit test voltage
VAC
Time type test HV
1 s
Insulation resistance
RI > 10 MOhm
Protection class
built-in fan
CE
EC Declaration of Conformity
Yes
EAC
Eurasian Conformity
Yes
UL
Underwriters Laboratories
Yes
VDE
Association for Electrical, Electronic and Information Technologies
Yes
CSA
Canadian Standards Association
Yes
CCC
China Compulsory Certification
Yes
Life expectancy L10 at TU = 40 °C
65.000 h
Life expectancy L10 at TU max.
30.000 h
Life expectancy L10 Delta (40 °C)
130.000 h
Life expectancy L10 acc. to IPC 9591 at TU = 40 °C
110.000 h
5 Safety
5.1 Electrical Safety
5.2 Approval Tests
Product Data Sheet ACi 4420 MLR
6 Reliability
6.1 General
3/9/2015 page 10 of 11
Page 11
Loading...