DC axial fans
Automotive series W3G300, Ø 300mm
Highlights:
– Control input: 0-10 VDC/PWM
– Load dump (58V)
– Over-voltage detection
– Over-temperature protected electronics
– Soft start, motor current limit, line undervoltage detection
– Over 85C with power derating
– Reverse polarity and locked rotor protection
Material: Impeller: PA plastic
Electronic housing: PA plastic
Mounting position: Any
Condensate discharge holes: None, open rotor
Direction of rotation: Clockwise, seen on rotor
(1)
(1)
(1)
(1)
Nominal Data
Air flow
Voltage
Voltage range
Power input
Speed
Current draw
Temperature range
Mass
Type Motor CFM VDC VDC Watts RPM A °C lbs rotor
W3G300-BV25-21 M3G084-BF 1897 26 16...32 380 3940
(1) Nominal data at free air.
-40...85/110C 4.4 Yes V IP 24 KM IP 6K 9K
14.6
Curves
Measurement: LU-141116
Air performance measured as per:
ISO 5801, Installation category
A, without protection against
accidental contact.
Suction-side noise levels: LWA as
per ISO 13347, LPA measured at
1m distance to fan axis.
The values given are valid
under the measuring conditions
mentioned and may vary accoring
to the actual installation situation.
With any deviation to the standard
set-up, the specific values have
to be checked and reviewed once
installed or fitted.
For detailed information on the
measuring set-up, please contact
ebm-papst.
2.40
2.00
4
1.60
1.20
0.80
0.40
0.00
ΔP [in. wg]
0 200 400 600 800 1000 1200 1400 1600 1800 200
3
2
1
[cfm]
Sealed ball bearings
Direction of air flow
(intake)
n
Pe
rpm
1
3940 380 14.6 79 87
2
3815 408 15.7 79 87
3
3715 462 17.7 78 85
4
3630 495 19.0 81 88
W
Ingress protection rating
(motor)
I ALpAin
dB(A)
Ingress protection rating
(electronics)
LwAin
dB(A)
W3G300-BV25-21
Direction of air flow "V"
Dimensions shown in millimeters
Connection screen
Connection line with plug Tyco Junior
Power Timer 1-962349-1, 6-pole, coded
Connection line (460 mm) with mating
connector part no. 02002-4-1021 not
included in scope of delivery
PWM/LIN (yellow)
Diagnostic output (white)
ABSENK (blue)
GND (brown)
+ UB (black)
INVLIN (orange)
Direction of air flow "V"
No. Conn. Designation Function/assignment
1 UB +26 VDC Power supply 26 VDC
2 GND Power supply GND, reference ground
3 PWMLIN Analogue voltage control input0-10Vor PWM
4 INVLIN Control input, inverse linear
5 ABSENK Lowering input
6 DU Diagnostic output