8412 NGLV
Nominal data
Type 8412 NGLV
Nominal voltage VDC 12
Nominal voltage range VDC 10 .. 14
DC axial compact fan
Speed (rpm) min-11500
Power consumption W 1.1
Min. ambient temperature °C -20
Max. ambient temperature °C 65
Air flow m3/h 33
Sound power level B 3.5
Sound pressure level dB(A) 12
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
ENU (Web) · Approved 2016-06-22 · Page 1 / 5
· · · · · ·

8412 NGLV
DC axial compact fan
Technical description
Housing material Glass-fiber reinforced PBT plastic
Impeller material Glass-fiber reinforced PA plastic
Weight 0.095 kg
Dimensions 80 x 80 x 25 mm
Airflow direction Exhaust over struts
Direction of rotation Counterclockwise, viewed toward rotor
Storage Sintec sleeve bearing
Service life L10 at 40 °C 80000 h
Service life L10 at maximum
temperature
Cable Leads AWG 24, TR 64, stripped and tin-plated.
Motor protection Protection against reverse polarity and blocked rotor.
Locked-rotor protection Locked-rotor and overload protection
Approval VDE, CSA, UL, CE
Option Possible custom designs:
45000 h
Speed signal
Go / No-go alarm
External temperature sensor
Internal temperature sensor
Moisture protection
ENU (Web) · Approved 2016-06-22 · Page 2 / 5
· · · · · ·

8412 NGLV
Product drawing
DC axial compact fan
ENU (Web) · Approved 2016-06-22 · Page 3 / 5
· · · · · ·

8412 NGLV
+
Temperatursensor
NTC
Temperature Sensor
Connection diagram
DC axial compact fan
ENU (Web) · Approved 2016-06-22 · Page 4 / 5
· · · · · ·

8412 NGLV
0 4 8 12 16 20
10 20
2,5
p
f
5
30
D
m³/h
Pa
V
•
2
1
30°C 50°C
7,5
CFM
0,030,020,01
(in H O)
²
S
S
Curves: Air performance
DC axial compact fan
ENU (Web) · Approved 2016-06-22 · Page 5 / 5
· · · · · ·