412
Nominal data
Type 412
Nominal voltage VDC 12
Nominal voltage range VDC 10 .. 14
DC axial compact fan
Speed (rpm) min-16000
Power consumption W 0.8
Min. ambient temperature °C -20
Max. ambient temperature °C 70
Air flow m3/h 10
Sound power level B 3.8
Sound pressure level dB(A) 18
ml = Max. load · me = Max. efficiency · fa = Free air · cs = Customer specification · ce = Customer equipment
Subject to change
ENU (Web) · Approved 2016-06-22 · Page 1 / 4
· · · · · ·

412
DC axial compact fan
Technical description
Weight 0.027 kg
Dimensions 40 x 40 x 20 mm
Impeller material Glass-fiber reinforced PA plastic
Housing material Glass-fiber reinforced PBT plastic
Airflow direction Exhaust over struts
Direction of rotation Counterclockwise, viewed toward rotor
Storage Sintec sleeve bearing
Service life L10 at 20 °C 50000 h
Service life L10 at 60 °C 20000 h
Cable Leads AWG 28, TR 64, stripped and tin-plated.
Motor protection Protection against reverse polarity and blocked rotor.
Approval VDE, CSA, UL
Option Possible custom designs:
Speed signal
Go / No-go alarm
PWM control input
Moisture protection
ENU (Web) · Approved 2016-06-22 · Page 2 / 4
· · · · · ·