Valid for heaters versions: Air heater Water heater
Order number module timer Display Display
DE
EN
6
87 9 1011 12
M0 °C
20:30
3
12345
All signals will start to flash on the display when the module timer is connected to the power supply. The switching clock must be entirely set. The heater cannot be switched on when the clock is in this state.
DE EN
Eberspächer
J. Eberspächer GmbH & Co. KG Eberspächerstr. 24 D-73730 Esslingen
11 Actual time 12 Preset 13 Heat 14 Setting backwards 15 Setting forwards 16 Memory display 17 Symbol for radio remote control 18 Weekday or preset day 19 Current time or preset time
10 Temperature display 11 Operating display 12 Temperature preselection – Range 10 to 30 °C
(Air heater only)
Telefon (zentral) (0711) 9 39-00 Telefax (0711) 9 39- 05 00
www.eberspaecher.com
Setting the time and weekday for the first time
Briefly press . Time display flashes 12:00. Set the current time with or . The time is stored as soon as it stops flashing. The weekday will then flash. Set the current weekday with or . The weekday is stored as soon as it stops flashing. The display is retained with ignition “ON”; the display is turned off after 10 sec­onds with ignition “OFF”.
Heater operation without preselection in ignition “OFF” state
Heating symbol = observe operating display.
Switching on the heater
120
Briefly press . Operating display and display of heating duration: The heating
duration is works adjusted to 120 minutes. It can be changed for a single heating period or permanently changed.
Changing the heating duration for a single heating period
After switch-on: Shorten heating duration (down to minimum 1 minute): Press . Lengthen heating duration (up to maximum 120 minutes): Press .
Changing the heating duration permanently
Do not switch on . Press and hold down (approx. 3 seconds) until the display appears and flashes. Release. Now set the heating duration (from 10 to 120 minutes) with or . The new heating duration has been stored when the display disappears.
Changing the time and weekday
Keep depressed until the time flashes. Then proceed as described on the left-hand side. If only the time is to be reset, then press twice after the time has been reset to skip flashing and weekday setting. After the weekday has been reset press to shorten the duration of weekday flashing.
Heater operation without preselection in ignition “ON” state
Heating symbol = observe operating display.
Switching on the heater
M0
20:45
Briefly press . Operating display as well as time and weekday.
The heater will continue to operate for as long as the ignition remains switched on. A residual heating time of 15 minutes continues after the ignition has been switched off. This can be lengthened to maximum 120 minutes by pressing , or shortened down to a minimum of 1 minute) by pressing .
Switching off the heater
Briefly press . The operating display disappears. The fan automatically continues to run to cool down the heater.
External switch “Heater ON / OFF”
If an additional switch has been mounted, then the heater can
be turned off from a remote point in the manner described above.
Turning off the heating
Briefly press . The operating display disappears. The fan continues to run to cool down the heater.
22 1000 90 95 53 01.2003 Subject to changes Printed in Germany © J. Eberspächer GmbH & Co. KG