Eberspächer Airtronic Operating Instructions Manual

Mini Controller
www.butlertechnik.com
www.butlertechnik.com
Operating Instructions / Mounting Instructions
Eberspächer
®
Temperature preselection control knob
• Left-hand end stop approx. 8 °C – small amount of heat
• Right hand end stop approx. 34 °C – large amount of heat
Heater
Red LED – Operation check for heater
Switch off (not in combination with mini clock)
Ventilator
Blue LED – operation check for ventilator
Order No. 22 1000 32 07 00
The mini controller enables you to set the heater installed in the vehicle to the temperature you require. You can either use the mini controller alone or in combination with the mini-clock.
Stand-alone mini-controller
Start heater – heating mode:
Use the button to start the heater in heating mode (continuous operation). You can adjust the required temperature with the control knob . If the heater is in heating mode, the red LED lights up as a check.
Start heater – ventilation mode:
Use the button to start the heater in ventilation mode (continuous operation). The control knob has no function in ventilation mode. If the heater is in ventilation mode, the blue LED lights up as a check.
J. Eberspächer GmbH & Co. Eberspächerstr. 24 D-73730 Esslingen
Telefon (zentral) (0711) 939-00 Telefax (0711) 939-0500
www.eberspaecher.com
Set preselected ventilation mode at the mini-controller:
Use the button to select ventilation mode – the preselection is saved. The temperature-preset controller has no function in ventilation mode. The blue LED lights up for approx. 3 secs as confirmation. However the heater is not started.
b) Heater is switched on (mini-clock active)
The ON / OFF button is used to switch on the saved mode (heater / ventilation – preselected by the mini-controller). If the heater is in Heater mode, the red LED lights up, in ventilation mode the blue LED lights up as a check.
Change between heating and ventilation modes using the mini-controller:
Use the button to change to heater mode. The set temperature required can be adjusted using the tempera­ture preset controller. If the heater is in heater mode the red LED lights up as a check. The preset operating mode is updated.
Switch off heater:
Use the button to switch off the heater. Heater or ventilation mode is terminated and the corresponding LED goes out. Heating mode is terminated with after run.
Mini controller combined with the mini-clock
If the mini-controller is installed in a vehicle together with the mini-clock, the mini-clock takes over the switch on / off function. In addition, it is now possible to program preset times. Informa­tion about programming is given in the enclosed operating and installation instructions for the mini-clock.
Note:
The button has no function when the controller is used in combination with the mini-clock. You can only switch the heater on / off using the mini-clock.
a) Heater is switched off (mini-clock inactive)
If the heater is switched off, it is possible to pre-select the heater or ventilation modes using the mini-controller. The heater itself can only be switched on via the mini-clock.
Set preselected heater mode at the mini-controller:
Use the button to select heater mode – the preselection is saved. You can adjust the set temperature required using the temperature-preset controller. The red LED lights up for approx. 3 secs as confirmation. However the heater is not started.
Use the button to change to ventilation mode. The temperature-preset controller has no function in ventilation mode. If the heater is in ventilation mode, the blue LED lights up as a check. The preselected operating mode is updated. Heater mode is terminated with after run.
Change the required set temperature using the mini-controller:
The required temperature can be adjusted at any time during heating mode using the temperature-preset controller.
Emergency operation – error when presetting the operating mode:
The preset operating mode was not able to be saved. The red LED flashes for approx. 10 secs. The mini-controller then switches to emergency operation (Preset heater mode). The heater remains switched off. Emergency operation can be reversed by carrying out the preselection process again or using a voltage reset (pull out the fuse).
If the heater is switched on by the mini-clock in emergency mode, the red LED lights up and flashes. The heater is in heater mode with preset set value.
It is not possible to change the operating mode in emergency mode. The heater can only be switched off via the mini-clock.
D
S
GB
Subject to change
www.butlertechnik.com
www.butlertechnik.com
Loading...