WARNING: DISCONNECT POWER AT THE MAIN
FUSE BOX BEFORE INSTALLATION.
WARNING:
This xture is intended for installation in
accordance with the National Electrical Code
(NEC) and all local code specications. If you are
not familiar with code requirements, installation
by a certied electrician is recommended.
Before assembly, remove all parts and part
packages from box. If anything is missing, please
contact the retailer from which the product was
purchased.
1. Carefully pull house wires out of junction box so
they are easily accessible during installation.
2. Position mounting bracket (A) so threaded ends
of attached xture mounting screws (E) are
facing out.
3. Carefully pull house wires through center hole
in mounting bracket (A).
4. Align holes in mounting bracket (A) with holes
in junction box.
5. Thread each junction box screw (B) into
appropriate holes in mounting bracket (A) and
into holes in junction box. Tighten junction box
screws (B) to secure mounting bracket (A) to
junction box.
CAUTION: Make sure house wires are pulled
completely through hole in mounting bracket.
DO NOT pinch wires between mounting bracket
and wall.
ANY QUESTIONS CALL: 800-613-3261
M-F 8:00AM-6:00PM ET
ITEM#: CN280172
JUNCTION
BOX
A
E
B
E
B
6. Strip 3/4” of insulation from ends of xture
wires.
7. Slightly loosen ground screw on mounting
bracket (A). Do not completely remove ground
screw. Wrap house ground wire (copper) around
ground screw, leaving enough ground wire
to attach to xture ground wire. Twist end of
xture ground wire and end of house ground
wire (copper) together. Twist wire connector
(C) onto ends of wires. Completely tighten wire
connector (C). Reference chart below for correct
wire connections
Connect Supply (House) Ground Copper Wire to:
Bare Copper Wire or,
Bare Silver Wire or,
Green Insulated Wire.
GROUND
SCREW
A
HOUSE
GROUND
WIRE
(COPPER)
C
FIXTURE
GROUND
WIRE
1
elkhome.com

ITEM#: CN280172
8. Twist end of house lead wire (black) and end of
xture lead wire together. Twist wire connector
(C) onto ends of wires. Completely tighten
wire connector (C). Twist end of house neutral
wire (white) and end of xture neutral wire
together. Twist wire connector (C) onto ends of
wires. Completely tighten wire connector (C).
Reference chart to the right for correct wire
connections.
9. Wrap electrical tape (not included) around wire
connectors (C) and wires. Ensure wires are
securely fastened into wire connectors.
10. Carefully push all wires and wire connectors into
junction box.
Connect Black Lead
Supply (House) Wire to:
Black Wire or,
*Parallel Cord
(Round and Smooth) or,
No printed words on
wire insulation or,
Insulated Wire
(other than green)
with Copper Conductor.
*When parallel wire (SPT 1 & SPT 2) is used:
The lead wire is round in shape or smooth.
The neutral wire is square in shape or ridged.
FIXTURE LEAD WIRE HOUSE LEAD WIRE
FIXTURE GROUND
WIRE
FIXTURE NEUTRAL
WIRE
Connect White Neutral
Supply (House) Wire to:
White Wire or,
*Parallel Cord
(Square and Ridged) or,
Printed words on
wire insulation or,
Insulated Wire
(other than green)
with Silver Conductor.
(BLACK)
HOUSE GROUND
WIRE (COPPER)
HOUSE NEUTRAL WIRE
(WHITE)
11. Place backplate (D) over mounting bracket (A).
Pass holes in backplate (D) over ends of xture
mounting screws (E). CAUTION: Do not pinch
wires between backplate and wall.
12. Screw one threaded cap (F) onto end of each
xture mounting screw (E). Tighten threaded
caps (F) to secure xture to wall. DO NOT over
tighten.
13. Pass hole in top of shade (K) over socket. Thread
socket ring (L) onto socket. Tighten socket ring
(L) to secure shade (K) in place.
14. Screw recommended bulb (E26 Edison bulb type,
not included) into socket. Verify correct bulb
wattage marked on socket of xture. WARNING:
DO NOT exceed maximum bulb wattage.
A
D
E
E
F
K
L
BULB
2