INSTALLATION INSTRUCTION
WARNING
IMPORTANT: NEVER attempt any work without shutting o the electricity.
- Read all instructions before installing.
- System is intended for installation by a qualied electrician in accordance with the National Electrical Code and local
regulations.
- Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or
switch ”OFF” the circuit breaker switch(es) that control the power to the xture or room that you are working on.
- Place the wall switch in the “OFF” position.
CAUTION
- All parts must be used as indicated in these instructions. Do not substitute any parts, leave parts out, or use any parts
that are worn out or broken. Failure to follow this instruction could invalidate the ETL/CETL listing of this xture.
CAUTION When handling the xture, do not apply pressure to the LEDs. Hold the xture by the base only.
AVERTISSEMENT
IMPORTANT : Coupez l’électricité avant TOUTE manipulation.
- Lisez toutes les instructions avant d’installer.
- Système est destiné à être installé par un électricien qualié en conformité avec le code national de l’électricité et les
règlements locaux.
- Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en posi
tion d’arrêt (« OFF »).
- Placez l’interrupteur mural en position d’arrêt (« OFF »).
MISE EN GARDE
- Toutes les pièces doivent être utilisées tel qu’il est indiqué dans ces instructions. Ne remplacez pas les pièces, n’en
laissez pas de côté et ne les utilisez pas si elles sont usées ou brisées. Le non-respect de ces instructions peut annuler
l’homologation ETL/CETL du luminaire. MISE EN GARDE Ors de la manipulation de l’appareil, ne pas appliquer de pression
à la LED, tenir l’appareil par la seule base.
ADVERTENCIA
IMPORTANTE: NUNCA intente hacer trabajos sin desconectar el suministro eléctrico.
- Lea y comprenda todas las instrucciones e ilustraciones por completo antes de proceder con el ensamblaje e insta
lación de esta lámpara.
- Sistema está disenado para ser instalado por un electricista calicado, de acuerdo con el código eléctrico nacional y las
normas locales.
- Diríjase a la caja de fusibles o a la caja del interruptor de circuito principal en su hogar. Coloque el interruptor de ali
mentación principal en la posición “OFF” (APAGADO).
- Coloque el interruptor de la pared en la posición “OFF” (APAGADO).
PRECAUCIÓN
- Todas las piezas deben usarse como lo indican estas instrucciones. No reemplace las piezas, noomita piezas durante la
instalación ni utilice piezas gastadas o rotas. El incumplimiento de esta indicación podría invalidar la calicación
ETL/CETL esta lámpara. PRECAUCIÓN Al manipular el aparato, no aplique presión a los LED, mantenga el aparato en la
base sólo.
HARDWARE
Wire
Connector
Qty: 3
Junction Box
Screw
Qty: 2 + 1 Extra
F1E1A1
Mounting
Screw
Qty: 2 + 1 Extra

INSTALLATION INSTRUCTION
PREPARATION
1. Shut o the power at the circuit breaker
and remove existing xture, including
the crossbar.
2. Carefully unpack your new xture and lay
out all the parts on a clear area. Be careful
not to lose any small parts necessary for
installation.
CONNECTING THE WIRES (Fig. 2)
3. Connect the xture wires to the junction box
wires as shown in Fig. 2, making sure that all wire
connectors (A1) are secured. If your outlet box
has a ground wire (green or bare copper),
connect the xture’s ground wire to it.
Otherwise, connect the xture’s ground wire
directly to the mounting plate (C1) using
the green screw provided. After wires are
connected, tuck them carefully inside the
junction box.
Connectors
A1
Junction Box
B1
Screw
Mounting Plate
C1
D1
E1
F1
G1
FIG.1
Junction
Box Screw
Canopy
Mounting
screw
Glass
5. Mount the canopy (E1) to the mounting plate,
aligning the keyholes with mounting screws (D1).
Twist the canopy and tighten screws (D1)
until secure.
6. Place the glass (G1) into the xture
frame (H1) and secure to the canopy (E1)
using screws (F1).
MOUNTING THE FIXTURE (Fig. 1)
4. Secure the mounting plate (C1) to the
junction box using the junction box screws (B1).
The side of the mounting plate marked “GND”
must face out.
100%-10% DIMMING
COMPATIBLE WITH THE FOLLOWING ELECTRONIC
LOW VOLTAGE (ELV) DIMMERS
Brand Model
LUTRON SELV-300P
LUTRON DVELV-300P
LEVITON MLE03-1
FIG.2
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare Copper
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
H1
Fixture
Frame