2-Way full-range stage monitor
See NOTES TABULAR DATA for details
CONFIGURATION
Subsystem: Transducer Loading
LF 1 x 15 in cone Vented
HF 1 x 1.4 in exit, 3 in voice Horn-loaded coil compression driver
Operating Mode: Amplifier Channels External Signal Processing
Single-amp LF/HF High Pass Filter Bi-amp LF,HF DSP w/2-way filters
PERFORMANCE1
Operating Range: 62 Hz to 20 kHz
Nominal Beamwidth (conical):
Horz 90° Vert 90°
Axial Sensitivity (whole space SPL): LF/HF 96 dB 62 Hz to 20 kHz
LF 97 dB 60 Hz to 904 Hz
HF 106 dB 710 Hz to 20 kHz
FEATURES
• Highly coherent coaxial design (15 inch LF)
• Enhanced fidelity and power handling
• Upgraded transducers and crossover design
• Switchable single-amp/bi-amp modes
• Convenient input connector location
DESCRIPTION
The MicroWedge MW15 is a collaboration between original MicroWedge Series inventor Dave “Rat” Levine (owner of Rat Sound Systems, Inc.) and the EAW Engineering Department, resulting in dramatically upgraded performance and ergonomics. A 15 inch woofer is paired with a 3 inch voice coil HF compression driver on a horn that provides full yet controlled 90 degree horizontal dispersion. All frequencies emanate from the exact same point, eliminating crossover region problems and time/phase irregularities, as well as optimizing coherency. The coaxial approach also contributes to a very compact, low-profile footprint.
MicroWedge MW15 monitors are processor enhanced (rather than processor dependant) for true “plug and play” operation. User selectable single-amp and bi-amp modes are provided. The large port on the front of the cabinet enhances LF response in coupling with the floor, and this port houses both the carrying handle and the passive/ active mode switch. The port also contains dual input connectors, keeping them concealed and protected, and allowing wedges to be placed as close together as desired. Additional cable can be stored in the port without impacting LF performance.
Rubber feet on the bottom of the enclosure reduce abrasion, and new integral rigging hardware – also mounted on the enclosure bottom – facilitates easy flying. The Baltic birch cabinets are protected with EAW’s RoadCoat™ finish that’s extremely durable, and the rugged steel grille keeps its distinctive shape even when stood upon. All components are highly liquid tolerant – virtually impervious to spilled drinks as well as natural elements like rain.
PRELIMINARY
Input Impedance (ohms): Nominal Minimum
LF/HF 8 6.3 @ 806 Hz
LF 8 7.4 @ 61 Hz
HF 8 7.0 @ 4597 Hz
High Pass Filter: High Pass=>50 Hz, 12 dB/octave Butterworth
Accelerated Life Test
LF/HF 89 dB 1000 W @ 8 ohm
LF 89 dB 1000 W @ 8 ohm
HF 35 dB 150 W @ 8 ohm
Calculated Axial Output Limit (whole space SPL): Nominal Minimum
LF/HF 126 dB 132 dB
LF 127 dB 133 dB
HF 128 dB 134 dB
ORDERING DATA
Description Part Number
MW15 2-Way Full-Range Loudspeaker Black 0030458-90
2
:
1 To achieve specied performance, the listed external signal processing with EAW-provided settings is required. 2 For recommendations to select power amplier size refer to : “HOW MUCH AMPLIFIER POWER DO I NEED?” on the EAW web site.
Page 2
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0030458-90 August 2008
M i cro W e dge M W 15 Speci f i cations group · S
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0030458-90 August 2008
M i cro W e dge M W 15 Speci f i cations group · S
NOTES:
1. SYMBOL INDICATES
18.00 [457.2] X 1.35 [34.3] FLY TRACK.
2. SYMBOL INDICATES CENTER OF BALANCE.
3. WEIGHT APPROX: 57.50 lb [27.1 kg].
4. SHIPPING WEIGHT APPROX: 72.5 lb [32.9 kg].
4.00
2.04 TSC
R 30.19
27°
DIMENSIONS APPLY TO BOTH SIDES
R 2.13
RIGHT SIDE
4X 0.25
(13°)
19.05 TSC
GRILLE
PARTIALLY
SHOWN
LOGO PLATE
HANDLE / PORT
FRONT
2X INPUT
13.82 TSC
14.1 TSC
[351.0]
L
C
[357.4]
[483.9]
[101.7]
4.00
20.37 TSC
14.75 TSC
TOP
24.17 TSC
[374.6]
[614.0]
C
L
[517.4]
[R 766.7]
[4X 6.3]
5.70 TSC
[144.7]
27°
MW15
PRODUCTION
LOUD Technologies Inc.
ONE MA IN STREET WHITINSVILLE, MA 01588 USA
2X 17.07
11.00
2X 2.36
[2X 59.9]
MODEL/SERIAL
NUMBER PLATE
[51.9]
[279.4]
[2X 433.7]
[101.6]
[R 54.0]
4X
RUBBER
FEET
BACK
11.21
[284.7]
14.68 [373.0]
C
L
ENCLOSURE
Material Baltic birch plywood
Finish RoadCoat™ wear resistant textured black paint Grille Powder-coated perforated steel
Page 3
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0030458-90 August 2008
M i cro W e dge M W 15 Speci f i cations group · S
10 100 1000 20000
120
110
100
80
70
60
10 100 1000 20000
20
10
0
-10
-20
-30
-40
100 1000 20000
360
100
10
1
10
0
-10
-30
-40
-50 10 100 1000 20000
10 100 1000 20000
100
1
PERFORMANCE DATA
See NOTES GRAPHIC DATA for details
FREQUENCY RESPONSE: PROCESSED MULTI-AMPLIFIED
LF = green, HF = black, Complete = blue
SPL (dB)
Frequency (Hz)
FREQUENCY RESPONSE: UNPROCESSED
LF = green, HF = black, Complete = blue
SPL (dB)
Frequency (Hz)
IMPEDANCE MAGNITUDE
LF = green, HF = black, Complete = blue
PRELIMINARY
FREQUENCY RESPONSE: DIGITAL SIGNAL PROCESSOR
LF = green, HF = black
dB re 0.775 V
Frequency (Hz)
BEAMWIDTH (-6 dB SPL Points)
Horizontal = orange Vertical = black
Ohms
Frequency (Hz)
Degrees
Frequency (Hz)
Page 4
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0030458-90 August 2008
M i cro W e dge M W 15 Speci f i cations group · S
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0030458-90 August 2008
M i cro W e dge M W 15 Speci f i cations group · S
HORIZONTAL POLAR DATA (Gridlines: 6 dB axial / 15 degree radial)
See NOTES GRAPHIC DATA for details
PRELIMINARY
Page 5
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0030458-90 August 2008
M i cro W e dge M W 15 Speci f i cations group · S
VERTICAL POLAR DATA (Gridlines: 6 dB axial / 15 degree radial)
See NOTES GRAPHIC DATA for details
PRELIMINARY
Page 6
Eastern Acoustic Works One Main Street Whitinsville, MA 01588 tel 800 992 5013 / 508 234 6158 fax 508 234 8251 www.eaw.com
EAW products are continually improved. All specifications are therefore subject to change without notice. Part Number: 0030458-90 August 2008
M i cro W e dge M W 15 Speci f i cations group · S
HPF
2-Way, Single-Amp (LF/HF)
2-Way, Bi-Amp (LF,HF)
AMP
XVR
HF
LF
DSP
EQ
DELAY
HPF/LPF
AMP
AMP
HF
LF
INPUT PANEL SIGNAL PANEL
LEGEND
DSP: User-supplied Digital Signal Processor. HPF: High Pass Filter for crossover or Recommended High Pass Filter. LPF: Low Pass Filter for crossover. LF/MF/HF: Low Frequency / Mid Frequency / High Frequency. AMP: User-supplied Power Amplifier. XVR: Passive LPFs, HPFs, and EQ integral to the loudspeaker.
NOTES
TABULAR DATA
1. Measurement/Data Processing Systems: Primary - FChart: proprietary EAW software; Secondary - Brüel & Kjær 2012.
2. Microphone Systems: Earthworks M30; Brüel & Kjær 4133
3. Measurements: Dual channel FFT; length: 32 768 samples; sample rate: 48 kHz; logarithmic sine wave sweep.
4. Measurement System Qualication (includes all uncertainties): SPL: accuracy +/-0.2 dB @ 1 kHz, precision +/-0.5 dB 20 Hz to 20 kHz, resolution 0.05 dB; Frequency: accuracy +/-1 %, precision +/-0.1 Hz, resolution the larger of 1.5 Hz or 1/48 octave; Time: accuracy +/-10.4 μs, precision +/-0.5 μs, resolution 10.4 μs; Angular: accuracy +/-1°, precision +/-0.5°, resolution 0.5°.
5. Environment: Measurements time-windowed and processed to eliminate room eects, approximating an anechoic environment. Data processed as anechoic or fractional space, as noted.
6. Measurement Distance: 7.46 m. Acoustic responses represent complex summation of the subsystems at 20 m. SPL is referenced to other distances using the Inverse Square Law.
7. Enclosure Orientation: For beamwidth and polar specications, as shown in Mechanical Specication drawing.
8. Volts: Measured rms value of the test signal.
9. Watts: Per audio industry practice, “loudspeaker watts” are calculated as voltage squared divided by rated nominal impedance. Thus, these are not True Watt units of energy as dened by International Standard.
10. SPL: (Sound Pressure Level) Equivalent to the average level of a signal referenced to 0 dB SPL = 20 microPascals.
11. Subsystem: This lists the transducer(s) and their acoustic loading for each passband. Sub = Subwoofer, LF = Low Frequency, MF = Mid Frequency, HF = High Frequency.
12. Operating Mode: User selectable congurations. Between system elements, a comma (,) = separate amplier channels; a slash (/) = single amplier channel. DSP = Digital Signal Processor. IMPORTANT: To achieve the specied performance, the listed external signal processing must be used with EAW-provided settings.
13. Operating Range: Range where the processed Frequency Response stays within -10 dB SPL of the power averaged SPL within this range; measured on the geometric axis. Narrow band dips are excepted.
14. Nominal Beamwidth: Design angle for the -6 dB SPL points, referenced to 0 dB SPL as the highest level.
15. Axial Sensitivity: Power averaged SPL over the Operating Range with an input voltage that would produce 1 W at the nominal impedance; measured with no external processing on the geometric axis, referenced to 1 m.
16. Nominal Impedance: Selected 4, 8, or 16 ohm resistance such that the minimum impedance point is no more than 20% below this resistance over the Operating Range.
17. Accelerated Life Test: Maximum test input voltage applied with an EIA-426B dened spectrum; measured with recommended signal processing and Recommended Protection Filter.
18. Calculated Axial Output Limit: Highest average and peak SPLs possible during the Accelerated Life Test. The Peak SPL represents the 2:1 (6 dB) crest factor of the Life Test signal.
19. High Pass Filter: This helps protect the loudspeaker from excessive input signal levels at frequencies below the Operating Range.
GRAPHIC DATA
1. Resolution: To remove insignicant ne details, 1/12 octave cepstral smoothing was applied to acoustic frequency responses and 1/3 octave cepstral smoothing was applied to the beamwidth and impedance data. Other graphs are plotted using raw data.
2. Frequency Responses: Variation in acoustic output level with frequency for a constant input signal. Processed: normalized to 0 dB SPL. Unprocessed inputs: 2 V (4 ohm nominal impedance), 2.83 V (8 ohm nominal impedance), or 4 V (16 ohm nominal impedance) referenced to a distance of 1 m.
3. Processor Response: The variation in output level with frequency for a constant input signal of 0.775 V = 0 dB reference.
4. Beamwidth: Average angle for each 1/3 octave frequency band where, starting from the rear of the loudspeaker, the output rst reaches -6 dB SPL referenced to 0 dB SPL as the highest level. This method means the output may drop below -6 dB SPL within the beamwidth angle.
5. Impedance: Variation in impedance magnitude, in ohms, with frequency without regard to voltage/current phase. This means the impedance values may not be used to calculate True Watts (see 9 above).