EAW CLA6, CLA4, CLA2 User Manual

CLA6 CLA4 CLA2
Column Loudspeakers
INSTRUCTION MANUAL
CLA Series 3

1. SAFETY INSTRUCTIONS

repnoitaruD
)sruoh(yad
leveldnuoS
)ABd(
elpmaxelacipyT
8 09 b
ulcllamsaniouD
6 2
9
4 59 n
iartyawbuS
3 7
9
2 0
01 cisumlacissalcduolyreV
5.1 201
1 5
01 teef05taevitomocoL
5.0 011
sselro52.0 511 trecnockcoratastraptseduoL
CAUTION AVIS
RISK OF ELECTRIC SHOCK • DO NOT OPEN
RISQUE DE
CHOC
ELECTRIQUE
NE PAS OUVRIR
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK
DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE
REFER SERVICING TO QUALIFIED PERSONNEL
ATTENTION: POUR EVITER LES RISQUES DE CHOC
ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE. AUCUN
ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER. CONFIER
L'ENTRETIEN AU PERSONNEL QUALIFIE.
AVIS: POUR EVITER LES RISQUES D'INCENDIE OU
D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE
A LA PLUIE OU A L'HUMIDITE
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure, that may be of sufficient magnitude to constitute a risk of electric shock to persons.
Le symbole éclair avec point de flèche à l'intérieur d'un triangle équilatéral est utilisé pour alerter l'utilisateur de la présence à l'intérieur du coffret de "voltage dangereux" non isolé d'ampleur suffisante pour constituer un risque d'éléctrocution.
The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
Le point d'exclamation à l'intérieur d'un triangle équilatéral est employé pour alerter les utilisateurs de la présence d'instructions importantes pour le fonction­nement et l'entretien (service) dans le livret d'instruction accompagnant l'appareil.
1. Read Instructions
3. Heed all Warnings
4. Follow all Instructions
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including ampliers) that produce heat.
9. Only use attachments/accessories specied by the manufacturer.
10. Refer all servicing to qualied service personnel. Servicing is required when the apparatus has been damaged in any way, such as liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
11. The entire sound system must be designed in compliance with the current standards and laws regarding electrical systems.
12. When installing and using this apparatus, keep in mind the technical specications indicated in the dedicated section of the manual.
13. Exposure to high sound levels can cause permanent hearing loss. The sound pressure level which leads to hearing loss varies considerably from one person to another, and depends on the duration of exposure. The U.S. Government’s Occupational Safety and Health Administration (OSHA) has established the maximum sound pressure levels that can be with stood without causing damage, which are shown in the table below. According to the OSHA regulations, any exposure over the maximum limits indicated in the table can reduce the hearing capacity of a person. To prevent potentially dangerous exposure to high sound pressure levels, anyone subjected to such levels must use suitable protection. When a EAW Commercial product capable of producing high sound levels is being used, it is therefore necessary to wear ear plugs or protective earphones when the limits shown in the table are exceeded. Consult the specications provided in the instruction manual to know the maximum sound pressure (SPL) the loudspeaker is capable of producing.
WARNING! This equipment has
been designed to be installed by qualied professionals only! There are many factors to be considered when installing professional sound reinforcement systems, including mechanical and electrical considerations, as well as acoustic coverage and performance. EAW Commercial strongly recommends that this equipment be installed only by a professional sound installer or contractor.
2 – CLA Series
Part No. 0010153 Rev. A 05/2004 © 2004 LOUD Technologies Inc. All Rights Reserved.
TABLE OF CONTENTS
1. SAFETY INSTRUCTIONS ........................................................ 2
2. INTRODUCTION....................................................................... 3
3. INSTALLATION ........................................................................ 4
4. CONNECTIONS ........................................................................ 5
5. SPECIFICATIONS..................................................................... 6
6. SERVICE INFORMATION........................................................ 7
7. WARRANTY ............................................................................. 7

2. INTRODUCTION

This manual describes the CLA series of column loudspeakers (CLA2, CLA4 and CLA6). These compact loudspeakers offer an attractive design and good acoustic features for quality speech and music reproduction.
The extended-range drivers guarantee high efciency, and a wide angle of coverage over the entire range reproduced. Each loudspeaker is equipped with an internal line transformer that makes it possible to connect it to constant voltage sound systems at 70 V or 100 V.
An easily accessible rotary switch allows you to select a range of ve output power values. A low cut switch is provided for reducing the level of the frequency range below 400 Hz for clear speech reproduction.
The galvanized steel body and metal grill are very sturdy, and the white color allows the CLA series to be easily integrated into any environment. The shape of the back of the body allows positioning in corners, and the light weight makes it possible to install them in false ceilings. Two L-type brackets are included.
Applications include:
Houses of Worship
Museums
Theme Parks
Transportation Terminals
Retail Spaces
Commercial Ofces
Conference Rooms
Schools
Distributed Systems
CLA Series – 3
CLA Series 5

3. INSTALLATION

The two support brackets provided can be used for installing the sound column on the wall or ceiling. Use the supplied bolts, plain washers and split lock washers to bolt the brackets to the loudspeakers.
WARNING: Make sure that the loudspeaker is installed in a stable and secure way in order to avoid any conditions that may be dangerous for persons or structures:
• Check to make sure that the support surface (e.g., wall, etc.) has the necessary mechanical characteristics to support the weight of the loudspeaker without the danger of it falling.
• Always use support elements suitable for the material of the wall that will support the loudspeaker (e.g., screw anchors for bricks, screw anchors for cement, etc.).
• Before suspending the loudspeaker, carefully check all the components to be used to make sure there is no damage, deformation, corrosion and/or missing or damaged parts that could reduce the safety of the installation.
Consult a professional rigger or structural engineer prior to suspending loudspeakers from a structure not intended for that use. Always know the working load limit of the structure supporting the loudspeaker. Always make sure that the rigging hardware minimum rating is at least ve times the actual load.
Installation precautions
• Use speaker cables with an adequate cross-section (gauge). The greater the distance between the amplier and loudspeaker, the larger the connection cable cross-section should be.
• To prevent inductive phenomena causing humming or distortion, the speaker cables should not be run together with electrical energy conductors, microphone cables, or line-level audio lines. Use speaker cables that have markings to distinguish the polarity, such as insulation or conductors of different colors.
• Avoid installing the loudspeaker in places exposed to harsh weather conditions.
4 – CLA Series

4. CONNECTIONS

1
ON
OFF
400 Hz LOW CUT
2
3
4
5
WARNING: To prevent the risk of electric shock, do not connect the loudspeaker or adjust the power selector with the amplier switched on.
The loudspeaker is designed to be connected to constant-voltage audio lines at 70 V or 100 V.
1. The white wire of the loudspeaker connects to the positive amplier output, the black loudspeaker wire connects to the negative amplier output.
2. Use a suitable tool to crimp the two supplied wires to the ends of your audio line conductors. Insulate the joints.
3. Using a small at screwdriver, rotate the power selector switch to the desired setting. The specications section on the next page shows the power settings for the three CLA loudspeakers.
4. If your system does not need to reproduce low frequencies, set the 400 Hz Low Cut switch to the ON position. This will reduce the output levels of the frequency range below 400 Hz.
Precautions
• Before using the loudspeaker, carefully check that all the connections have been
• Check if your power amplier’s constant output voltage is 70 V or 100 V, and nd
• The sum of the operating power values of all the loudspeakers connected to the
• Verify that the connections to all of your loudspeakers are made correctly “in
made correctly to make sure there are no accidental short circuits that could cause electrical sparks.
the rated power output.
audio line must not exceed 80 % of the amplier’s output power.
phase.” When different loudspeakers reproduce the same frequencies but with phase differences, there may be sound cancellation. Loudspeakers are often situated in adjacent positions and the sound waves interact with each other. If a loudspeaker is connected incorrectly; i.e., the polarity of the audio line conductors is inverted, the audio signals are transmitted with differences in phase and correct reproduction is therefore jeopardized. Most notably, the bass response may suffer.
CLA Series – 5
CLA Series 7

5. SPECIFICATIONS

1
2
3
4
5
Width
3.82 "
97.0 mm
Length
Depth
Model CLA2 CLA4 CLA6 Rated Power Woofers Tweeter SPL (1 W/m) Max SPL (20 W/m) Freq Range (-10 dB) Horizontal Dispersion
(1 kHz/4 kHz) Low Cut Vertical Dispersion
(1 kHz/4 kHz) Length Depth Width Weight Mounting supplied
Power Selector
20 W 30 W 40 W 3” x 2 3” x 3 3” x 4 2” x 1 2” x 1 2” x 1 87 dB 88 dB 90 dB 100 dB 103 dB 106 dB 150 Hz-20 kHz 140 Hz-20 kHz 140 Hz-20 kHz 190˚/120˚ 195˚/105˚ 205˚/140˚
400 Hz 400 Hz 400 Hz 125˚/30˚ 105˚/30˚ 85˚/45 ˚
11.97”/304 mm 15.24”/387 mm 18.46”/469 mm
3.74”/95 mm 3.74”/95 mm 3.74”/95 mm
3.7”/94 mm 3.7”/94 mm 3.7”/94 mm
3.97 lbs/1.8 kg 5.07 lbs/2.3 kg 6.39 lbs/2.9 kg 2 L-brackets 2 L-brackets 2 L-brackets
CLA2
CLA4
CLA6
Switch Position 70 V Power (W) 100 V Power (W) Impedance 1 20 Do not use 250 Ω 2 10 20 500 Ω 3 5 10 1 kΩ 4 2.5 5 2 kΩ 5 1.25 2.5 4 kΩ
Switch Position 70 V Power (W) 100 V Power (W) Impedance 1 30 Do not use 167 Ω 2 15 30 333 Ω 3 7.5 15 666 Ω 4 3.75 7.5 1.33 kΩ 5 1.9 3.75 2.67 kΩ
Switch Position 70 V Power (W) 100 V Power (W) Impedance 1 40 Do not use 125 Ω 2 20 40 250 Ω 3 10 20 500 Ω 4 5 10 1 kΩ 5 2.5 5 2 kΩ
Disclaimer
EAW Commercial continually engages in research related to product improvement, new materials, and production methods. Design renements are introduced into existing products without notice as a routine expression of that philosophy. For this reason, any current EAW Commercial product may differ in some respect from its published description, but will always equal or exceed the original design specications unless otherwise stated.
“EAW Commercial” is a trademark of LOUD Technologies Inc.
All other brand names mentioned are trademarks or registered trademarks of their respective holders, and are hereby acknowledged.
6 – CLA Series

6. SERVICE INFORMATION

In the event that your CLA loudspeaker should require servicing, please follow these
instructions:
1. Call EAW Commercial Tech Support at 1-888-337-7404, 7 am to 5 pm PST (Monday-Friday), to verify the problem and obtain a Return Authorization (RA) Number. Be sure to have the serial number of the unit when you call. You must have a Return Authorization Number in order to obtain warranty service at the factory or at an authorized service center. You can also email EAW Commercial Tech Support at: support@eawcommercial.com
2. Pack the unit in its original packaging. THIS IS VERY IMPORTANT. LOUD Technologies is not responsible for any damage that occurs during shipping due to non­conventional packaging. Original packaging helps to minimize the possibility of shipping damage.
3. Include a legible note stating your name, (no P.O. boxes), daytime phone number, Return Authorization Number, and a detailed description of the problem, including how we can duplicate it.
4. Write the Return Authorization Number in BIG BOLD PRINT on top of the box.
5. Tech Support will tell you where to ship the unit when you call for an RA Number. We suggest insurance for all forms of cartage.

7. WARRANTY

Warranty: LOUD Technologies Inc. requires its authorized EAW Commercial distributors
abide by the following warranty terms for all EAW Commercial brand products (all dates are from the date of delivery from an Authorized EAW Commercial Distributor to the end user/installation site):
Loudspeakers – 5 years; Active Electronics – 5 years; Accessories – 2 years.
What Is Covered: Defects in workmanship and materials and against malfunctions. EAW
Commercial distributors must remedy all such defects and malfunctions without charge for parts or labor if the warranty applies. Final determination of warranty coverage lies solely with each authorized EAW Commercial distributor.
What Is Not Covered: This warranty does not extend to damage or malfunctions
resulting from, but not limited to, shipment, improper installation, misuse, neglect, abuse, normal wear, accident, or to any product on which the serial number has been modied or removed. Exterior defects in or damage to the exterior appearance are specically excluded from this warranty. EAW Commercial distributors shall not be liable for incidental or consequential damages resulting from the use of EAW Commercial products. Repairs and/or modications by other than an Authorized EAW Commercial Distributor automatically voids this warranty.
CLA Series – 7
EAW Commercial | One Main Street | Whitinsville, MA 01588 USA
TEL toll free within US/Canada 888.337.7404 | TEL outside US 425.892.6503 | FAX 425.485.1152
www.eawcommercial.com
© 2004 LOUD Technologies Inc. All Rights Reserved. EAW Commercial is a registered trademark of LOUD Technologies Inc.
Loading...