This manual contains important instructions that you should follow during installation and maintenance of the battery cabinet. Please read all instructions before operating the equipment and save this manual for future reference.
This is a product for commercial and industrial application in the second environment. Installation restrictions or additional measures may be needed to prevent disturbances.
©
2013 Eaton
Corporation
All Rights
Reserved
The contents of this manual are the copyright of the publisher and may not be reproduced (even extracts) without the written approval of Eaton Corporation. Every care has been taken to ensure the accuracy of the information contained in this manual, but no liability can be accepted for any errors or omission. The right to make design modifications is reserved.
Contents
1
Safety instructions
........................................................................................................................ 1
1.1
Symbols on the UPS and accessories ................................................................................................... 1
1.2 Conventions used in this manual ........................................................................................................... 2
1.3 General ................................................................................................................................................... 2
1.4
Audience
.............................................................................................................................................. 4
1.5 CE
marking
............................................................................................................................................ 4
1.6 User
precautions
................................................................................................................................ 4
1.7
Environment
......................................................................................................................................... 5
1.8 For more
information
........................................................................................................................... 5
2
Installation
....................................................................................................................................... 6
2.1 Preparing the Small Battery Cabinet installation
.............................................................................. 8
2.2 Preparing the Large Battery Cabinet installation
............................................................................ 10
2.3 Installation with other than 93PM or 93E UPS
................................................................................ 13
3 M
aintenance
.................................................................................................................................. 14
3.1
Important
safety instructions
.......................................................................................................... 14
3.2
Performing
preventive maintenance
.............................................................................................. 15
3.2.1 PERIODIC maintenance ......................................................................................................... 15
3.2.2 ANNUAL maintenance ............................................................................................................ 15
3.2.3 BATTERY maintenance .......................................................................................................... 15
3.3
Recycling
the
used
UPS or
batteries
........................................................................................... 15
3.4
Maintenance training
........................................................................................................................ 16
4
Technical data
............................................................................................................................... 17
4.1
Standards and regulations
.............................................................................................................. 17
4.2 Battery
specification
.......................................................................................................................... 18
4.3
Environmental specifications
.......................................................................................................... 18
5
Warranty
......................................................................................................................................... 19
6
Installation checklist
.................................................................................................................... 20
P-164000427 SMALL and LARGE BATTERY CABINET 1 Revision 2 User's and Installation Guide
1
Safety instructions
1.1
Symbols on the UPS and accessories
The following are
examples
of
symbols used
on the UPS or
accessories
to alert you to
important
information:
DANGER
RISK OF
ELECTRIC
SHOCK - Indicates
that a
risk of electric shock is
present
and the
associat
ed warning should be
observed.
CAUTION
CAUTION: REF ER TO O PERATOR’S M ANUA L
-
Refer to your
operator’s
manual for
addition
al
information,
such as
important
operating and maintenance instructions.
Figure 1-1:
Recycling
batteries symbol
This symbol
indicates
that you should not
dis-
card the UPS or the UPS
batteries
in
the
trash.
This
product
involves
sealed,
lead-acid
batteries
and
must
be
disposed
of properly. For more in-
formation, contact
your local
recycling/reuse or
hazardous
waste center
.
Figure 1-2:
WEEE
symbol
This symbol
indicates
that you should not
dis-
card
waste
electrical or
electronic
equipment
(WEEE) in the trash. For proper
disposal,
contact
your local
recycling/reuse
or
hazardous waste center.
P-164000427 SMALL and LARGE BATTERY CABINET 2 Revision 2 User's and Installation Guide
1.2 Conventions used in this manual
This manual
uses these
type
conventions:
Bold
type highlights important concepts in discussions, key terms in procedures, and menu options, or
represents a command or option that you type or enter at a prompt.
Italic type highlights
notes
and new terms where they are defined.
Icon
Description
NOTE
Information notes
call
attention
to
important
features or
instructions.
1.3 General
The battery cabinet contains components that carry high currents and voltages. The properly installed enclosure is earthed and IP21 rated against foreign objects and is safe to operate. However, only qualified personnel are allowed to install and service the battery cabinet.
DANGER
This equipment contains LETHAL VOLTAGES. All repairs and service should be performed by AUTHORIZED SERVICE PERSONNEL ONLY. There are NO USER SERVICEABLE PARTS inside the equipment.
P-164000427 SMALL and LARGE BATTERY CABINET 3 Revision 2 User's and Installation Guide
WARNING
To reduce the risk of fire or electric shock, install this battery cabinet in a
temperature and humidity controlled, indoor environment, free of conductive contaminants. Ambient temperature must not exceed 40 °C (104 °F). Do not operate near water or excessive humidity (95 % maximum). The system is not intended for outdoor use.
Ensure all power sources are disconnected before performing installation or service. Power may come from multiple sources.
Ensure
system grounding/PE continuity when undertaking installation
or
service.
Batteries
can
present
a risk of
electrical shock
or burn from high
short-circuit current.
ELECTRIC ENERGY HAZARD.
Do not
attempt
to alter any
battery
wiring or
connectors.
Attempting
to alter wiring can
cause injury.
Do not
open
or
mutilate batteries. Released electrolyte
is harmful to the skin and
eyes.
It may be
toxic.
IMPORTANT:
the
battery
may
consist
of
multiple
parallel
strings, disconnect
all
strings
before installation.
CAUTION
Installation
or
servicing should
be
performed
by
qualified
service personnel
knowledgeable
of
batteries
and required
precautions.
Keep
unauthorized
personnel
away
from
batteries. Consider
all
warnings, cautions,
and
notes before installing
or
replacing
batteries.
DO NOT DISCONNECT the
batteries while
the UPS is in Battery
mode.
Replace batteries
with the
same number
and type of
batteries
as
originally installed.
Disconnect
the
charging source
prior to
connecting
or
disconnecting terminals.
Determine
if the
battery circuit
is
inadvertently grounded.
If it is,
remove
the
source
of
the
ground. Contacting
any part of a
grounded battery
can
cause
a risk
of
electric shock. An
electric shock
is
less
likely if you
disconnect
the
grounding
connection before
you
work
on the
batteries.
Proper
disposal
of
batteries
is required. Refer to local
codes
for
disposal
requirements.
Do not
dispose
of
batteries
in a fire.
Batteries
may
explode when exposed
to
flame.
Keep the door
closed
and front
panels installed
to
ensure
proper
cooling
airflow
and
to
protect personnel
from
dangerous voltages inside
the
unit.
Do not install or
operate
the UPS
system close
to gas or
electric
heat
sources.