Features
• Provides clean, continuous power to protect critical equip­ment and applications from power-related downtime, data loss and corruption, and process interruption
• Saves valuable rack space by delivering 6000 VA/4200W in only 3U
• Offers deployment versatility through rack and tower installation options with rail kits and pedestals provided
• Increases availability with hot-swappable batteries and power module
• Offers extended battery runtime options to power essential systems for more than an hour during an outage
Product snapshot
Power rating: 6 kVA/4.2 kW
Voltage: 230V nominal,
200–250 Vac range
Frequency: 50/60 Hz (auto-sensing)
Configuration: Rackmount (3U) or tower
Advanced power protection for:
• Medium-density data centers
• Banking and security systems
• Manufacturing process control
• Retail point-of-sale systems
• Telecommunications/VoIP equipment
The Eaton® 9135 UPS, Power-
®
series, resolves utility
ware power problems and sup­plies continuous, conditioned power. You get clean power for valuable IT and network­ing equipment, battery back­up to gracefully handle utility outages, and on-demand visi­bility into UPS status from anywhere.
Get more usable power for less cost
The 9135 provides exactly the level of power protection needed under the conditions of the moment—optimizing for both efficiency and perfor­mance. The more efficient the UPS, the lower your utility and cooling bills.
Under normal power condi­tions, the UPS can operate in high-efficiency mode at up to 97 percent efficiency. In double conversion mode, the UPS operates at up to 91 percent efficiency.
Double-conversion design for superior reliability and protection
In double conversion mode, the 9135 is constantly moni­toring power conditions— regulating both voltage and frequency. Even when pre­sented with the most severe power problems, this UPS’s output remains within two percent of nominal voltage.
With a wide range of acceptable input voltages, this UPS does not depend on batteries to smooth out power fluctuations. Batteries are conserved for those times when utility power is highly unstable or completely out. If an outage occurs, the 9135 transfers to battery with no break in power, making this an ideal UPS for equipment sensitive to voltage fluctuations.
More power in less space
High power density. The 9135 increases power density, deliv­ering 6000 VA/4200W in only 3U of rack space, freeing more rack space for IT and telecom equipments. Rail kits and tower pedestals are included with every 9135 for flexible installation.
Rack model and EBM installation
Hot swappable batteries
This UPS is even more user-friendly than its predecessors offering greater distribution capabilities, with eight IEC 10A & two IEC 16A outlets to power multiple pieces of equipment without a PDU.
You can combine the 9135 with an Eaton enclosure PDU (ePDU™) to power an entire rack of equipment from a single power cord input. ePDU outlets can be monitored, switched, sequenced and managed individually, providing maximum flexibility in distributing power from the 9135.
Maximum availability for critical systems
Battery runtime for minutes or hours. During a power outage, internal batteries in the 9135 keep loads running long enough to gracefully shut down systems. Add up to four external bat­tery modules (EBMs) to deliver more than an hour of extended runtime at full load—or hours under lighter loads. Each EBM occupies only 3U of rack space. These battery modules are hot-swappable and can be replaced at any time without inter­rupting UPS operation and load protection.
Maximum battery runtime for critical equipments. LanSafe power management software enables independent control of load segments. With this feature, you can manage scheduled shutdowns and sequential startups of protected loads. During a power outage, you could shut down power to less essential loads to extend battery backup time for more critical devices.
Load segments
ConnectUPS-MS Network Management Card web interface
When the load segments feature is used with optional Connect UPS-MS connectivity cards, users can remotely re-boot lock­ed-up network equipment. Simply access the ConnectUPS-MS card over the network, and toggle the password-protected load segment controller to get your network back online.
Service without downtime.
The 9135 features hot-swappable
components and an automatic internal bypass. The UPS auto­matically switches to an alternate power path within the unit if it senses a trouble condition with an internal component. Users can even remove and replace the battery and power modules without powering down the UPS or interrupting po­wer to loads.