easyRAID Q12QS-4GR2 Hardware User Manual

Page 1
easyRAID Q12QS-4GR2
Hardware User Manual
42-30000-5104
iSCSI 1Gb to SAS
Disk Array System
Version 1.1
Page 2
Page 3
easyRAID Q12QS-4GR2
iSCSI 1Gb to SAS
Disk Array System
Hardware User Manual
Page 4
Page 5
i
Table of Contents
Preface................................................................................................................... i
Chapter 1 System Requirements
Operating Environment ....................................................................................1
VT100 Terminal Settings ..................................................................................1
Chapter 2 Basic Configuration
Unpacking ............................................................................................................. 3
Components ..........................................................................................................4
Closed Front Panel ...........................................................................................4
Open Front Panel .............................................................................................5
Disk Tray ..........................................................................................................6
Rear View .........................................................................................................7
Installing Disks ......................................................................................................8
Making Connections ...........................................................................................10
Connecting the Host Interface ........................................................................10
Connecting a network .....................................................................................10
Expanding additional JBOD enclosure............................................................11
Connecting and Turning on the Power ...........................................................12
Mounting in a Rack .............................................................................................13
Installing the Rail Extenders ...........................................................................14
Chapter 3 Maintenance
Replacing a Disk .................................................................................................15
Replacing a Power Supply ..................................................................................16
Upgrading Memory .............................................................................................17
Appendix
Hardware Specifications .....................................................................................21
Page 6
Page 7
i
Preface
About this Manual
This manual is designed to make the disk array system as easy to use as possible. Information contained in this document has been checked for accuracy, but no guarantee is given that the con­tents are correct. Information and specifications are subject to change without notice.
Copyright Notice
© Copyright 2007
All rights reserved. This disk array system and related documentation are protected by copyright and are distributed under licenses restricting their use, copying, and distribution. No part of this documentation may be reproduced in any form by any means without prior written authorization and its licensors, if any.
Conventions
Caution
This symbol is used to remind users to pay attention to important descrip­tions regarding usage and maintenance (repair) or additional important information related to this disk array system.
Note
This symbol is used to remind users of useful information that can make procedures such as configuration easier to accomplish.
Page 8
ii
easyRAID Q12QS-4GR2 SAS Disk Array System
Preface
– Important Safety Instructions, Care and Handling
Important Safety Instructions, Care and Handling
Before starting, take a few minutes to read this manual. Read all of these instructions and save this manual for later reference.
Protect the disk array system from extremely high or low temperatures. Let the disk array system warm (or cool) to room temperature before using it.
Protect the disk array system from being bumped or dropped. Do not place the disk array system on an unstable cart, stand, or table. It may fall, causing serious damage to the product.
Keep the disk array system away from magnetic forces.
Do not use the disk array system near water.
Keep the disk array system away from dust, sand, or dirt.
Gaps and openings in the cabinet are provided for venti­lation. Never block or cover these openings, because the disk array system may overheat and become unreli­able. Don’t place the disk array system on a bed, sofa, rug, or other similar surface.
Do not place the disk array system near or over a radia­tor or other heat source.
Refer to the rating plate for the correct voltage and ensure that the appliance voltage corresponds to the supply voltage.
V
Page 9
easyRAID Q12QS-4GR2 SAS Disk Array System
iii
Preface
– Important Safety Instructions, Care and Handling
The appliance must be grounded. The disk array system is equipped with a 3-wire grounded type of power cord. This power cord will only fit into a grounded type of power outlet.
If an extension cord or a power center is used with the disk array system, make sure that the total current con­sumption of all products plugged into the wall outlet does not exceed the ampere rating.
Do not place the disk array system where the cord will be walked on.
Never push any kind of object into the disk array system through cabinet gaps and openings, since they may touch dangerous voltage points and cause a risk of fire or electric shock.
Unplug the power cord from the wall outlet before clean­ing. Keep the disk array system dry. Do not use liquid cleaners, aerosol cleaners, or a wet cloth. Use a damp cloth for cleaning.
Except as specifically explained in this User Manual, do not attempt to service the disk array system by yourself. Opening or removing the covers may expose you to dangerous voltages.
Unplug this product from the wall outlet and refer servic­ing to qualified service personnel under the following conditions.
• If the disk array system has been exposed to water or any liquid.
• If the disk array system has been dropped or the cabinet damaged.
Users should not remove the cover.
Disconnect all power supply cords before servicing.
Fan 1
Power 1
o
GGwGGY
Page 10
iv
easyRAID Q12QS-4GR2 SAS Disk Array System
Preface
– Important Safety Instructions, Care and Handling
Placement Notes
• The disk array system LCD panel can be damaged by exposure to direct sunlight. Limit exposure to subdued or indirect sunlight only.
• The disk array system should be used only in clean environments that are free from airborne contaminants such as dust, dirt, and smoke. Excessive moisture or oil particles in the air can also hinder disk array system performance.
• To reduce the possibility of data errors caused by electromagnetic interference, locate the disk array system at least five feet away from electrical appliances and equipment that generates magnetic fields.
Power Supply Safety Notes
• To avoid electric shocks, do not use an extended power cord or an outlet that does not match the disk array system plug or leaves the plug exposed.
• The disk array system has a 3-wire grounded plug. The third pin connects to ground; do not remove it.
• If the power cord or plug is damaged or worn, unplug it immediately and contact a qualified service technician for maintenance.
• To avoid fire or electric shocks, do not overload electric power out­lets.
CAUTION : MULTIPLE POWER SOURCES
Disconnect all AC power cords to completely power from the unit
CAUTION
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
CAUTION
The thumbscrews on the rear surface shall be secured by the screw­driver, which cannot be loosened by bare hands to prevent the uninten­tional access to the hazardous parts inside the equipment.
Page 11
1
1 System Requirements
Ensure that the following requirements are met before installing the disk array system.
Operating Environment
• 15 cm (6-inches) of space around the disk array system for proper ventilation
• ambient temperature of 5°C to 40°C (40°F to 104°F)
• ambient non-condensing relative humidity of 20% to 80%
• dust, smoke, and oil free environment
• no large magnetic fields, such as those generated by a high voltage power cables and motors, etc.
• no direct sunlight
• a flat, stable surface capable of supporting the disk array system
VT100 Terminal Settings
Refer to the following table for a summary of VT100 terminal settings required to communicate with the disk array system. Refer to your system manual for instructions on setting up the VT100 terminal settings.
Item Required Setting
Connection Serial Port (COM1 or COM2)
Protocol RS232 (Asynchronous)
Cabling Null Modem cable
Baud Rate 115200
Data Bits 8
Stop Bit 1
Parity None
Page 12
Page 13
3
2 Basic Configuration
This chapter describes disk array system connections and disk installation.
Unpacking
Contact your supplier if any of the following items are missing or damaged.
Caution
The disk array system is heavy. Be careful when lifting and moving it.
Power P/S Fail Access
Enter ESC
Hardware User Manual
easyRAID Q12QS-4GR2
iSCSI to SAS
Disk Array System
Power P/S Fail Access
Enter ESC Pri/Sec
Power P/S Fail Access
Enter ESC Pri/Sec
Software User Manual
easyRAID Q12QS-4GR2
iSCSI to SAS
Disk Array System
Power Cables
Front Panel Keys
Hardware and software user Manuals
Disk Array System
RS-232 Cable
Screw pack
Rails
Rail Extenders
Fix Screw pack M5
Fix Screw pack UNC #10-32
Fix Screw pack M6
RJ45 Lan Cable
Page 14
4
easyRAID Q12QS-4GR2 SAS Disk Array System
2
Basic Configuration – Components
Components
Closed Front Panel
No. Name Description
1 LCD panel
Displays warning, operating, and configuration information.
2 Power-on indicator Indicates the disk array system power is on.
3 Power supply fail indicator Indicates a failed power supply.
4 Host computer access indicator
Indicates data transfer between the disk array sys­tem and the host computer.
5 Up function button Moves up in the LCD menus.
6 Down function button Moves down in the LCD menus.
7 Enter function button Selects a menu item or confirms a choice or entry.
8 Escape function button
Returns to the previous LCD menu without making changes.
9 Lock Locks front cover.
Power P/S Fail Access
Enter ESC
1
3 4
5 6
2
7
8 9
Page 15
easyRAID Q12QS-4GR2 SAS Disk Array System
5
2
Basic Configuration – Components
Open Front Panel
No Name Description
1-12 Disk trays 1-12 Removable hot swap disk trays
13 Front panel door Protects the disks and houses the LCD panel
Disk1
Disk2
Disk3
Disk4 Disk5 Disk6
Disk7
Disk8
Disk9
Disk10 Disk11 Disk12
Disk Mapping
Color Status
Bule Access Green Disk Online Red No Disk
Tray LED Indication
1 2 3 4 5 6 7 8 9 10 11 12
13
Page 16
6
easyRAID Q12QS-4GR2 SAS Disk Array System
2
Basic Configuration – Components
Disk Tray
No. Name Description
1
Power/Error indicator LED Different colors indicate different disk states:
• Green – Disk online
• Orange – Disk full
• Red No disk
2 Access indicator LED
This blue LED indicates that the disk is being accessed.
3 Tray handle Releases the disk tray.
2
1
Front
3
Page 17
easyRAID Q12QS-4GR2 SAS Disk Array System
7
2
Basic Configuration – Components
easyRAID Q12QS-4GR2 Rear View
Ter m
UPS
LAN
Ch 3Ch 1
EXP
Ch 4Ch 2
1
8911 10
1314
2
7
15
6
3 4 5
12
No. Name Description
1
Cooling fan 1
System cooling fan.
2
iSCSI Host Port 1/2
Connects to the host server.
3
RS-232 Port
Connects to a VT100 terminal or equivalent.
4
UPS port
Data port for uninterruptable power supply.
5
iSCSI Host Port 3/4
Connects to the host server.
6
Cooling fan 2
System cooling fan.
7
Power Supply 2
Removable redundant power supply 2.
8
Power Supply Handle
For power supply removal.
9
Power Supply AC In
Connects to a 100-240 VAC power source.
10
Power Supply Switch
Switches the power on or off.
11
Ethernet Port
Used for browser-based configuration.
12
Expansion Port
Used for JBOD expansion.
13
Power Supply 1
Removable redundant power supply 1.
14
Power Supply Handle
For power supply removal.
15
Power Supply AC In
Connects to a 100-240 VAC power source.
Page 18
8
easyRAID Q12QS-4GR2 SAS Disk Array System
2
Basic Configuration – Installing Disks
Installing Disks
This section describes how to install disks in the disk array system.
1 Unlock the front panel door, then pull it open.
2 Push the button (A) to release the disk tray handle. Pull the handle (B) to release the tray.
3 Align the rear of the disk with the rear of the disk tray. 4 Insert the disk into the disk tray and fix into place with screws supplied with the disk.
Disk1
Disk2
Disk3
Disk4 Disk5 Disk6
Disk7
Disk8
Disk9
Disk10 Disk11 Disk12
Disk Mapping
Color Status
Bule Access Green Disk Online Red No Disk
Tray LED Indication
A
B
Page 19
easyRAID Q12QS-4GR2 SAS Disk Array System
9
2
Basic Configuration – Installing Disks
5 Slide the disk tray back into the empty slot (A), then slowly close the disk tray handle
(B).
6 Repeat steps 2 to 5 until all of the required disks have been installed. 7 Push the front panel door closed, and lock it.
B
A
Disk1
Disk2
Disk3
Disk4 Disk5 Disk6
Disk7
Disk8
Disk9
Disk10 Disk11 Disk12
Disk Mapping
Color Status
Bule Access Green Disk Online Red No Disk
Tray LED Indication
Page 20
10
easyRAID Q12QS-4GR2 SAS Disk Array System
2
Basic Configuration – Making Connections
Making Connections
After the required number of disks have been installed, external connections to the disk array system must be made. This section describes how to make all of the necessary connections.
Connecting the Host Interface
The disk array system has quad iSCSI 1Gb interfaces.
Internet Small Computer Systems Interface
Follow these instructions to make connections.
1 Connect the ethernet cable (A) to the connector of the easyRAID Q12QS-4GR2 iSCSI
port at the rear of the disk array system.
Connecting a network
Connect the network cable to the RJ-45 port at the rear of the unit.
A
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Page 21
easyRAID Q12QS-4GR2 SAS Disk Array System
11
2
Basic Configuration – Making Connections
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Expanding additional JBOD enclosure
Use a x4 external SAS cable (SFF 8088 to SFF 8470) to connect the EXP(A) port of RAID system to the EXP(B) port of the next easyRAID Q16JS-S3R3.
Then, use a x4 exteral SAS cable (SFF 8088 to SFF 8088) continue to connect the CH1 (C) port of previous easyRAID Q16JS-S3R3 to the EXP (D) port of the next easyRAID Q16JS-S3R3.
Note
• It can expand up to THREE of easyRAID Q16JS-S3R3 to a single RAID system.
easyRAID Q12QS-4GR2 RAID System
easyRAID Q16JS-S3R3-1
easyRAID Q16JS-S3R3-2
easyRAID Q16JS-S3R3-3
(A)
(B)
(C)
(D)
Page 22
12
easyRAID Q12QS-4GR2 SAS Disk Array System
2
Basic Configuration – Making Connections
Connecting and Turning on the Power
1 Plug a power cable (A) to a power connector at the rear of the unit, then plug the second
power supply cable into the second power connector (B).
2 Switch on both power supplies.
Note
The system is equipped with auto switching power supplies that can run on 100 to 240 VAC.
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
B
A
Page 23
easyRAID Q12QS-4GR2 SAS Disk Array System
13
2
Basic Configuration – Mounting in a Rack
Mounting in a Rack
When the disk array system is completely set up, it can be installed in a standard 19-inch rack. Follow the instructions in this section to install the disk array system in a rack.
1 Clip eight rack nuts supplied with your rack, into the rack, taking care that they corre-
spond with the mounting points on the rails.
2 Extend both of the rails so that they are the right length to fit in your rack. 3 Bolt the rails into the rack using the rack bolts supplied with your rack.
You will need four nuts and bolts (not included) for each rail; two at the front and two at the back.
4 Tighten the locking screws when they are the correct length. 5 Slide the disk array system into the rack and bolt it into place with the supplied fixing
screws.
Caution
This product is heavy. Attempting to install the disk array system in a rack by yourself could result in injury or damage to the product.
Page 24
14
easyRAID Q12QS-4GR2 SAS Disk Array System
2
Basic Configuration – Mounting in a Rack
Installing the Rail Extenders
Follow these instructions to fit the rail extenders if required.
1 If required, bolt the rail extenders into place as shown using the small bolts provided. 2 Slide the disk array system into the rack and bolt it into place with the supplied fixing
screws.
Note
The rail extenders may be required to allow the disk array system room for the front door to open correctly.
Page 25
15
3 Maintenance
Replacing a Disk
A disk failure is indicated when the Power/Error LED at the front of the drive tray turns red and the audible alert sounds.
The LCD panel displays the failure with the symbol “R” or “W”. “R” indicates a disk failure or error, and “W” indicates that there are too many bad sectors on the disk.
Disks are hot swappable, which means that they can be inserted and removed while the disk array system is powered on and operating. Follow these instructions to replace a failed disk.
1 Unlock the front panel door, then pull it open. 2 Pull the tray handle away from the disk tray to release it; and pull the disk tray out. 3 Remove the screws from the failed disk, then remove the disk from the disk tray. 4 Align the rear of the new disk with the rear of the disk tray.
5 Insert the new disk into the disk tray.
6 Attach the disk to the disk tray with the screws that came with the disk. 7 Slide the disk tray back into the empty slot, then close the disk tray handle. 8 Push the front panel door closed, and lock it.
Note
Turn off the audible alert by pressing the Up and Down function but­tons on the front panel twice simultaneously.
Note
The new disk must have the same or a greater capacity than the faulty disk that was removed. If the disk capacity is smaller, the audible alert sounds and the auto-rebuild operation doesn’t start. For best performance, it is recommended that the new disk be identical to the failed disk.
1 1 1 1 1 2 2 2 2 2 W R
Example:
• Disks 1 to 5 are members of array group 1.
• Disks 6 to 10 are members of array group 2.
• Disk 11 has too many bad sectors.
• Disk 12 has an error or a fault.
Page 26
16
easyRAID Q12QS-4GR2 SAS Disk Array System
3
Maintenance – Replacing a Power Supply
Replacing a Power Supply
The disk array system is equipped with a Power Supply Fail Indicator LED at the front of the unit that turns red when one of the power supplies fails. The message “Power x failure” also appears on the LCD panel, where x refers to power supply 1, or 2, and an audible alert sounds.
Power supplies are hot swappable, which means that they can be inserted and removed while the disk array is powered on and operating. Follow these instructions to replace a failed power sup­ply.
1 Identify the power supply that has failed.
2 Remove the power cable from the power supply connector at the rear of the unit.
3 Loosen the power supply retaining screw.
Note
Turn off the audible alert by pressing the Up and Down function but­tons on the front panel twice simultaneously.
Note
The system is equipped with auto switching power supplies that can run on 100 to 240 VAC.
Ter m
UPS
LAN
Ch 3Ch 1
EXP
Ch 4Ch 2
Power Supply 1 Power Supply 2
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Power Supply retaining screw
Page 27
easyRAID Q12QS-4GR2 SAS Disk Array System
17
3
Maintenance – Replacing a Power Supply
4 Pull the power supply handle out.
5 Remove the faulty power supply by pulling the power supply handle A and pressing the
release catch B at the same time.
6 Insert a new power supply.
7 Push the power supply handle into place. 8 Tighten the power supply thumbscrew.
9 Reconnect the power cable.
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Release catch
B
A
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Page 28
18
easyRAID Q12QS-4GR2 SAS Disk Array System
3
Maintenance – Upgrading Memory
Upgrading Memory
The disk array system takes a single DDR II 400/533 DIMM with a maximum capacity of 2 GB. Follow these instructions to upgrade the memory.
1 Loosen the screws holding the controller cage in place. 2 Slide the controller-cage out of the chassis.
3 Pull the DIMM retaining clips away from the DIMM; the DIMM springs out of the
socket. Remove the DIMM.
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
LAN
Host 1
Host 2
UPS
Term
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Page 29
easyRAID Q12QS-4GR2 SAS Disk Array System
19
3
Maintenance – Upgrading Memory
4 Gently push the new DIMM into the socket, then push the corners of the DIMM down.
The DIMM is secured by the DIMM retaining clips.
5 Push the controller cage back in, lower the handle, and tighten the retaining screws.
Note
The DIMM module will fit in only one direction. Do not force the DIMM into place.
LAN
Host 1
Host 2
UPS
Term
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Term
UPS
Ch 3
Ch 4
Ch 1
Ch 2
LAN
EXP
Page 30
Page 31
21
Appendix
Hardware Specifications
Item Specification
Host Interface Quad channel (4) RJ45 Network Connectors
Disk Interface SAS
Dimensions 88 mm (H) x 447 mm (W) x 565 mm (D)
Weight 19 Kg without disks
RAID Functions • Raid levels: JBOD, 0, 1, 0+1, 3, 5, 10, 30, 50, 6, 60
• Hot spare support
• Disk hot swapping with automatic online rebuilding
• Multiple RAID (max. 8)
Disk Array Func­tions
• O/S independent and transparent
• 1GB ~ 2GB DDRII 400/533 DIMM
• LCD panel operation indicator
• Audible alarm/disable alarm
• LED indicator on disk failures
Connectors • 1 x RS-232 Serial port (115200, 8, N, 1)
• 4 x RJ-45 Ethernet port (1Gbps)
• 1 x RJ-45 Ethernet port (10/100 Mbps)
Power Supply • Redundant 1 + 1, 350 Watt
• 100 - 240 VAC, 47-63 Hz, 8~4A +/- 10%
• Over voltage, current, power, and short circuit protection
• LED indicates power status
• Operating temperature: 5°C ~ 40°C
• Output: +5V, +3.3V, +12V
Warranty 3 year warranty
Safety UL, CE and FCC Class B
Page 32
22
easyRAID Q12QS-4GR2 SAS Disk Array System
Appendix
– Hardware Specifications
Controller
Backplane
Item Specification
CPU
Intel Xscale IOP342 (Chevelon dual core)
Disk Interface SAS
Disk Channels 12 channels
Memory Sockets 1
Memory Size Up to 2 GB
LCD Interface One LCD panel, 2 lines by 16 charac-
ters
Button Interface Up, Down, Enter, and ESC
Backplane Interface (connector)
Compact-PCI
Temperature Sensors 3
Disk Channel Support 12 channels
Disk Number Supported 12 disks
Disk Connector Type SAS
Temperature Sensors 7
Power Connector Type 2 x Slot-2
Fan Connector Type 2 x Slot-2
Loading...